1 General safety information Specified use The drive unit is only intended for vertically moving sectional doors with full counter- balancing. The drive unit must be protected against moisture and aggressive environmental conditions (such as corrosive substances). The drive units are only suitable for indoor use. Appropriate protective measures must be taken for outdoor installation.
Page 5
Warning - Failure to follow these installation instructions may result in severe injury or death. Please read these instructions before using the product. Keep these instructions handy. Include these instructions when passing on the product to third parties. Warning - Danger from improper use of the product! ...
2 Technical Data Type SG 50E Output torque Output speed Output shaft / hollow shaft 25,40 Maximum output speed open / close 26 / 26 for frequency inverter operation Maximum holding torque Maximum door weight 6000 Supply voltage 3N~ 400...
3 Mechanical installation Prerequisites The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques (▶ refer to technical data). Connection elements: ▶ Self-locking connection ▶ Utilize the hole diameter ▶...
Page 8
Mounting Eight threads are provided for mounting. ▶ Use at least 2 of these (①). Keys are used to connect to the door shaft. ▶ Use a key that is at least as long as the hollow shaft (②). BAGAD0 1 0 0 1 _Z0 0 2 8 x (M8x16)
Page 9
Installation The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation. Warning - Potential injury or danger to life! During installation, be sure to use a lifting device that has a sufficient load- carrying capacity.
Page 10
▶ Attach the drive unit. BAGAE0 1 0 0 3 _Z0 0 3 ▶ Tighten all connection elements (M8) to 25 BAGAE0 1 0 0 6 _Z0 0 2 Nm. Install all other connection elements according to the specifications of the door manufacturer.
4 Electrical installation Warning - Danger to life from electric current! Switch the mains OFF and check that the cables are de-energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover.
9 Emergency manual operation (release) Emergency manual operation is designed for opening or closing the door without power supply. Warning – Injuries due to incorrect operation! Switch off voltage. Door movement possible after release Warning - Danger of the door dropping! If you need to apply more than the permissible force of 390N (according to DIN EN 12604/DIN EN 12453) to move the door by emergency manual operation, this indicates a stalling on the drive unit or door.
Page 16
Switch on by pulling the red handle. Open or close the door by hand. Switch off by pulling the green handle.
10 Completing commissioning / inspection Check the following components and then install all covers. Gearbox Check the drive unit for loss of oil (a few drops can be neglected). Protect the output-shaft permanently against corrosion. Mounting Check that all connection elements (consoles, torque mounts, screws, locking rings, etc.) are secure and in proper condition.
Declaration of incorporation / Declaration of conformity Declaration of incorporation within the meaning of Machinery Directive 2006/42/EC for partly completed machinery, Appendix II Part B Declaration of conformity within the meaning of EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH &...