Altec AIR CO2-PG80 Operation & Maintenance Manual

Altec AIR CO2-PG80 Operation & Maintenance Manual

Purge gas generator

Advertisement

Quick Links

SECTION 1
Serial Numbers
Description of Operation
SECTION 2
SECTION 3
Flows, Connections, Dimensions, and Weights
SECTION 4
Installation
Electrical Connections
Piping and Connections
SECTION 5
Start-Up
SECTION 6
Maintenance
SECTION 7
Replacement Parts
SECTION 8
SECTION 9
Wiring Diagram
SECTION 10 Warranty / Claims
CO2-PG80 PURGE GAS GENERATOR
OPERATIONS & MAINTENANCE

TABLE OF CONTENTS

Pg 2
Pg 3
Pg 3
Pg 4
Pg 5
Pg 5
Pg 6
Pg 7
Pg 8
Pg 8
P/N P013253 REV B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CO2-PG80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Altec AIR CO2-PG80

  • Page 1 CO2-PG80 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE TABLE OF CONTENTS SECTION 1 General Information: Model Description Pg 2 Serial Numbers Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation Safety Operation Safety SECTION 3 Specifications: Pg 3 Flows, Connections, Dimensions, and Weights...
  • Page 2 SECTION 1 GENERAL INFORMATION MODEL DESCRIPTION The CO2-PG80 Purge Gas Generator is designed to remove water and CO from a compressed air stream. This is done by passing the air through beds of adsorbent media (using 13X molecular sieve) which adsorbs both H...
  • Page 3 Altec AIR CO2-PG80 Purge Gas Generator Operations and Maintenance Manual OPERATION SAFETY SECTION 2 SAFETY INSTRUCTIONS OPERATE CO2-PG80 PURGE GENERATOR AT COMPRESSED AIR PRESSURES ABOVE 150 PSIG. UNIT FAILURE, INJURY AND EQUIPMENT INSTALLATION SAFETY DAMAGE COULD RESULT Before starting or installing the CO2-PG80 Purge Gas...
  • Page 4 Altec AIR CO2-PG80 Purge Gas Generator Operations and Maintenance Manual INLET BULKHEAD OUTLET FITTING BULKHEAD FITTING FIG 2 SECTION 4 INSTALLATION 4 . 4 MO UNT I NG Table top PARTS INCLUDED The unit comes with rubber feet installed on bottom of cabinet for use on table top.
  • Page 5 Altec AIR CO2-PG80 Purge Gas Generator Operations and Maintenance Manual SECTION 5 START UP Below is a suggested schedule based on average operating conditions. As conditions such as dirty environment, humidity BEFORE UNIT START UP, FOLLOW THE INSTALLATION conditions, ambient temperature, etc. change, the frequency of INSTRUCTIONS AND PROCEDURES COMPLETELY.
  • Page 6 Altec AIR CO2-PG80 Purge Gas Generator Operations and Maintenance Manual SECTION 7 REPLACEMENT PARTS Part Number Description (refer to FIG 3) Call Factory POWER ON/OFF SWITCH B03-02-G000 OUTLET FILTER/REGULATOR WITH GAUGE PS403 - OUTLET FILTER ELEMENT ONLY P77413 - GAUGE ONLY...
  • Page 7 Altec AIR CO2-PG80 Purge Gas Generator Operations and Maintenance Manual SECTION 7 TROUBLESHOOTING GUIDE A PROBLEM: UNIT DELIVERS WET AIR OR HIGH CO LEVELS POSSIBLE CAUSE CHECK CORRECTIVE ACTION A1 High inlet air temperature. For standard units, inlet air Reduce inlet air temperature to proper temperature should be 70-80°F.
  • Page 8 Authorization (RMA). RMA may be obtained from our service CO2-PG80 WIRING DIAGRAM department. All defective parts/equipment must be returned freight prepaid to the Altec AIR factory within 30 days of RMA issue date. Any shipment returned to the factory collect will be refused.

Table of Contents