1. Introduction
1.1
Applications
The TH146-N-2H1C electronic controller can be used with any of
the following heating/cooling systems:
• Heat pump - 1H1C, 2H1C
• HVAC - 1H, 1C, 1H1C
The following devices can be connected to the controller:
• air recirculation fan
• humidifier
• dual-register meter (dual energy)
• remote control device (for the unoccupied mode)
1.2
Supplied Parts
• CT280-2H1C control module
• TH146 console with two wall anchors and mounting screws
• AC144-03 outdoor temperature sensor (3 m or 10 ft) with
mounting clip (see section 2.6)
1.3
Accessories
• RC845 relay (see section 2.4)
• AC146-410 plenum temperature sensor (see section 2.7)
• CT241 telephone controller (see section 2.9)
TH146-N-2H1C
Removable
Connector *
CT280-2H1C Control Module
TH146-N-2H1C
Non-programmable H/C Controller
Removable
Connector *
2. Installation
2.1
Control Module (CT280-2H1C)
Configure the control module according to your type of heating/
cooling system using DIP switches on the back of the module.
Install the control module near the heating/cooling system, away
from any heat source.
2.2
User Console (TH146)
Install the console in a central location. Avoid locations with air
drafts (e.g., top of staircase or air outlet) or stagnant air (behind a
door). Do not install the console on a wall hiding air ducts nor
expose it to direct sunlight.
NOTE: If this controller replaces an old thermostat, any two of the
wires that were connected to the thermostat can be used to connect
the user console to the control module. The maximum wiring length
is 30 m (100 ft).
Installation Guide
AC144-03 Outdoor
Temperature Sensor
1/8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TH146-N-2H1C and is the answer not in the manual?

Questions and answers

Richard Mongeau
February 15, 2025

Aubé TH146-N-2H1C Model is not heating with the auxiliary electric furnace long enough when the Gree heat pump can’t supply enough heat at -15*C or colder.Would changing setting 6 help and if yes how can I do that

Summary of Contents for Aube Technologies TH146-N-2H1C

  • Page 1 2. Installation Applications Control Module (CT280-2H1C) The TH146-N-2H1C electronic controller can be used with any of Configure the control module according to your type of heating/ the following heating/cooling systems: cooling system using DIP switches on the back of the module.
  • Page 2 • fan limit if gas heating is used (HVAC only) O: The keypad is unlocked. • high pressure protection during defrost cycle (This protection is generally needed for add-on installations only. It is not needed if the heat pump is not connected to the controller terminal WW.) TH146-N-2H1C...
  • Page 3: Principles Of Operation

    NOTE: This condition will not apply if the AC146-410 plenum sensor is not connected to the controller. NOTE: For Smart Fan to work, set the fan to On (see user guide). NOTE: The auxiliary heat’s short-cycle protection is disabled during defrost. TH146-N-2H1C...
  • Page 4: Wiring Tables

    Power (24 Vac)      Cooling unit (24 Vac / 1 A)   Heating unit (24 Vac / 1 A) Not used Fan (24 Vac / 1 A)    Not used Not used TH146-N-2H1C...
  • Page 8: Configuration Menu

    Note 1: Parameters 2 to 6 are not available when the controller is configured for HVAC or 1H1C heat pump. Note 2: Parameters 7 and 8 are not available when the controller is configured for heat pump. Printed in USA 02-2013 TH146-N-2H1C...
  • Page 9: Installation

    2. Installation Applications Module de contrôle (CT280-2H1C) Le contrôleur électronique TH146-N-2H1C peut être utilisé avec Configurer le module de contrôle selon votre type de système de n'importe lequel des systèmes de chauffage et climatisation chauffage et climatisation au moyen des sélecteurs à l’arrière du suivants : module.
  • Page 10 • protection contre la surpression durant le cycle de dégivrage (la sonde n’est généralement nécessaire que pour les installations « add-on» (installations modifiées). Elle n’est pas nécessaire si la thermopompe n’est pas reliée à la borne WW du contrôleur.) TH146-N-2H1C...
  • Page 11: Principes De Fonctionnement

    • Le ventilateur fonctionne sans arrêt le reste du temps. NOTA : La protection anti-court cycle du chauffage d’appoint est NOTA : Pour que la fonction «Smart Fan» fonctionne, placer le désactivée lors du dégivrage. ventilateur en mode « On» (voir le guide de l’utilisateur). TH146-N-2H1C...
  • Page 12   Alimentation (24 Vca)      Refroidissement (24 Vca / 1 A)   Chauffage (24 Vca / 1 A) Non utilisée    Ventilateur (24 Vca / 1 A) Non utilisée Non utilisée TH146-N-2H1C...
  • Page 16 Note 1 : Paramètres 2 à 6 ne sont pas disponibles si le contrôleur est configuré pour un système CVAC ou une thermopompe 1H1C. Note 2 : Paramètres 7 et 8 ne sont pas disponibles si le contrôleur est configuré pour une thermopompe. Imprimé aux É.-U. 02-2013 TH146-N-2H1C...

Table of Contents