Features
10 selectable Sensitivities
4 selectable Frequencies
Wrong voltage protection
Output Timing – Extend &
Delay
Selectable Presence times
Selectable Pulse lengths
Separate Power, Detect and
Fault Indicators
Automatic Sensitivity Boost
Available in: 240VAC, 120VAC,
24VAC, 24VDC or 12VDC

Specifications.

Size:
Weight:
Relay Output Rating:
Power Supply:
Temperature Range:
Inductance Range:
Lead-In Length:
Loop Frequency:
1 3/8" wide x 3 3/32" high x 3 1/2" long.
Eight (8) ounces, approximate.
7A, 277VAC/30VDC.
240VAC, 120VAC, 24VAC, (24VDC, 12VDC)
Consumption – 70mA DC or 1 Watt AC.
-30 to +180 Fahrenheit.
20 to 1500 microhenries, automatically tuned.
Up to 2500 feet with proper loop and lead-in.
Four selectable frequencies, typically in the range of 40 to 150 KHz.