Electrical Pump PREMAxx 230 V AC, single phase 24 V DC 12 V DC Operating Instructions Contents: General information 1.1 Intended use 1.2 Construction and functional description 1.3 Technical data 1.4 Area of application 1.5 Requirements of installation site General Safety Notes 2.1 Notes concerning work safety...
• Nozzle in one of the above mentioned versions. Although the PREMAxx electrical pump is not a self-priming pump, it is quickly ready for use in connection with the integrated priming stage. The priming stage enables manual priming of the delivery fluid before start of operation and secures emergency service for minimum quantities in the event of power loss.
Table 1-2: General technical data Area of application The PREMAxx electrical pump is only designed for pumping diesel and fuel oil, if they are not heated above the flash point. The temperature of the delivered fluid must be between -10 °C and +35 °C. The temperature limits must not be exceeded.
2. General Safety Notes Notes concerning work safety The PREMAxx electrical pump is designed and built according to the appropriate health and safety requirements of the relevant EC guidelines. This product can nevertheless produce hazards if it is not used according to its purpose or without the necessary care (=>...
Operating Instructions PREMAxx Electrical Pump Risks when using the PREMAxx electrical pump Danger! Combustible fuels can cause explosions Do not smoke whilst handling the pump and fuels. Danger! Flying sparks can cause explosions Do not operate the pump in areas with a risk of explosions.
PREMAxx Electrical Pump Operating Instructions 3. Assembly Figure 3-1: Overview of PREMAxx electrical pump with accessories Pump housing 11 Thread of standard nozzle Hand lever 12 On/off switch Barrel screw joint 13 Pressure union Suction union 14 Union nut of delivery hose...
Page 7
Operating Instructions PREMAxx Electrical Pump Assembly of PREMAxx electrical pump 1. Push the transparent suction hose (6) onto the suction pipe with filter (8). 2. Push the hose clamp (7) over the suction hose (6) to the suction pipe (8) and tighten the hose clamp with a screwdriver.
PREMAxx Electrical Pump Operating Instructions 4. Operation First operation and renewed operation Caution! Risk of product damage Before switching on the pump for the first time, and in the event of a low fluid head: Manually prime with diesel or fuel oil, as a dry run of the pump can destroy the radial shaft gasket.
Operating Instructions PREMAxx Electrical Pump Delivery fuel (for automatic nozzle version) Note With a locked nozzle trigger, the automatic nozzle switches off automatically, as soon as the tank or container being filled is full. Furthermore, the automatic nozzle switches off when the nozzle is held vertically or falls down whilst the nozzle trigger is locked.
6. Let the emerging fuel oil or diesel run into the oil tray. 6. Maintenance The PREMAxx electrical pump is in principle low maintenance and low service. Due to the operator duty according to § 191 WHG, the following parts of the pump must be...
PREMAxx Electrical Pump Operating Instructions 8. Declaration of EC Conformity We herewith declare that the appliance described below corresponds with the EC guidelines with regards to its design and type of construction as well as in the version as marketed by us.
Need help?