Download Print this page

CBS C-RD-SONDE Operating Manual

Duct calibration sonde and detector

Advertisement

Quick Links

CBS Products Ltd, Pillings Road, Oakham, Rutland, LE15 6QF UK
Fax: +44 (0)1572 756009
C-RD-SONDE AND C-RD-CAT-F
DUCT CALIBRATION SONDE AND
All rights reserved. No part of this publication may be copied, reproduced or
transmitted in any form whatsoever without the written permission of CBS Products
Ltd.
E-mail:
sales@cbsproducts.com
OPERATING MANUAL
DETECTOR
Copyright ©2004 by CBS Products Ltd
Tel: +44 (0)1572 723665
Website: www.cbsproducts.com

Advertisement

loading

Summary of Contents for CBS C-RD-SONDE

  • Page 1 C-RD-SONDE AND C-RD-CAT-F DUCT CALIBRATION SONDE AND DETECTOR Copyright ©2004 by CBS Products Ltd All rights reserved. No part of this publication may be copied, reproduced or transmitted in any form whatsoever without the written permission of CBS Products Ltd.
  • Page 2 REVISION HISTORY Date Details Author 07-2004 Original Issue A. Miller A. Miller 1.25” and1.5” details added 09-2004 03-2006 Details for assembly C-1262-AS1001 added A. Miller 01-2012 Responsible Person Updated L.Kilpin...
  • Page 3: Table Of Contents

    CONTENTS: Duct Calibration Sonde C-RD-SONDE and Locator C-RD-CAT-F Introduction Safety Instructions General Description Specification Operating Procedure Assembly and Maintenance Spare Parts Sonde Assembly and Calibration Nose Selection Chart CE Certificate...
  • Page 4: Introduction

    1.0 Introduction CBS Products Ltd is a long established U.K company situated in rural Oakham, Rutland. From its 4-acre site, CBS design, manufacture, test and market a comprehensive range of quality products for the electricity, telecommunication and CATV industries. Products include overhead line and underground winches, cable drum trailers and stands, stringing equipment, in fact everything required for the installation or erection of conductors and cables.
  • Page 5: Safety Instructions

    2.0 Safety Instructions The Duct Calibration Sonde is operated employing pneumatic compressed air upto 3 bar (45psi). Compressed air has a potential energy to expand and accelerate materials, therefore care should be taken at all times during the operation to keep the pressure as low as possible.
  • Page 6: General Description

    3.0 General Description The Duct Calibration “Sonde” and Detector have been designed to ensure that ducts being employed for cable blowing have unrestricted bores, or locates the point(s) where ducts are damaged or restricted. This operation should be conducted prior to the cable blowing operation and the ducts left capped and sealed.
  • Page 7: Specification

    “Sonde” standard housing is 22 mm diameter, (other sizes available ). Two duct seals fitted (Two spares) to suit specified duct bore One Electronic Sonde Signal Generator and Battery (C-RD-SONDE-F) 33 kHz (8xAA batteries) One Catcher Stocking (E-958-3810) One Set of Operating Instructions One Detector:- Radiodetection Model complete with batteries (C-RD-CAT-F) Maximum depth of operation 1.9m.
  • Page 8 5.0 Operation Instruction See diagram Figure 1 for typical layout of a duct requiring calibration prior to cable blowing. To calibrate the duct the following procedure should be employed. Fit the catcher stocking to the Exit End of the duct. Ensure that stocking is applied at least 200mm over the end of the duct.
  • Page 9 Always check the operation of the sonde and detector before inserting the sonde into the duct. DO NOT PROCEED IF SIGNAL IS NOT DETECTED. Rectify the fault and proceed. Always check the condition of the duct seals, replace if necessary. Set the compressor to 3 bar (45 psi) or pressure regulator in the duct line to 3 bar.
  • Page 10: Assembly And Maintenance

    Assembly and Maintenance Sonde Assembly Sonde Shock Body Absorber Tail Endpiece Cone Nose Electric Duct Sonde Module Seal Adaptor 2 off Check the battery condition of the electric module. Replace if necessary (see figure 5.1.1) ensure that “O” ring seal is fitted correctly (see fig 5.1.2). It is recommended that a spare battery is always available.
  • Page 11 Detector Refer to the instructions on the detector body before using the unit. Check the condition of the batteries (it is recommended that a spare set of batteries are always available). Replace if necessary. Check the function of the detector with the sonde unit. If either are not working correctly NOT PROCEED until the fault has been rectified.
  • Page 12 7.0 Spares For spare parts always quote the model type, serial number and contact:- CBS PRODUCTS LIMITED PILLINGS ROAD OAKHAM RUTLAND LE15 6QF TEL: +44 (0)1572 723665 FAX: +44 (0)1572 756009 E-MAIL: sales@cbsproducts.com TYPICAL SPARES: Sonde Electric Module Battery C-RD-SONDE-01-F...
  • Page 13 8.0 SONDE ASSEMBLY AND CALIBRATION NOSE SELECTION GUIDE ADDITIONAL CALIBRATION NOSE CONES TO SUIT OUTSIDE DIAMETER (MM) DUCT SONDE KIT SONDE BORE ASSEMBLY (mm) INC. IN SONDE A2-1262-012-29 C-R-SONDE-29 ASSEMBLY 31.75 INC. IN SONDE C-R-SONDE-31.75 A2-1262-012-31.75 A3-1262-013-24 A3-1262-013-28 (1.25”) ASSEMBLY INC.
  • Page 14: Ce Certificate

    CE CERTIFICATE DECLARATION OF CONFORMITY MANUFACTURER: CBS Products Limited Pillings Road OAKHAM Rutland LE15 6QF MODEL NUMBER: C-R-SONDE- SERIAL NUMBER: DESCRIPTION: SONDE MANUFACTURED IN ACCORDANCE WITH THE SUPPLY OF MACHINERY (SAFETY) REGULATIONS 1992 (S.I. 1992/3037) AND IN CONFORMANCE WITH THE ESSENTIAL HEALTH AND SAFETY REQUIREMENTS.