Download Print this page
WarmPool WP120 Inverter Installation And Operation Manual

WarmPool WP120 Inverter Installation And Operation Manual

Hide thumbs Also See for WP120 Inverter:

Advertisement

Quick Links

Installation and operation manual WP
~ 1 ~

Advertisement

loading

Summary of Contents for WarmPool WP120 Inverter

  • Page 1 Installation and operation manual WP ~ 1 ~...
  • Page 2 Installation and operation manual WP 1. Warning First and foremost, check the condition of your heat pump as soon as you receive it, write any reservations you have about its state on the delivery note if you have any doubts or a problem and send a registered letter to your installer or directly to the manufacturer within 48 hours.
  • Page 3: Technical Characteristics

    Installation and operation manual WP 2.2 Technical characteristics MODEL WP120 Inverter WP120 Inverter Tri WP140 Inverter WP140 Inverter Tri Pool size Maxi 120m³ 120m³ 140m³ 140m³ Heating capacity * 4.6~19.5 4.6~19.5 5.7~24.2 5.7~24.2 Power consumption * 0.37~3.94 0.37~3.94 0.46~4.8 0.46~4.8 COP * 12.43~4.95...
  • Page 4 Installation and operation manual WP 2.3 Dimension of swimming pool heat pump WP120 Inverter / WP120Tri Inverter 2.4 Dimension of swimming pool heat pump WP140 Inverter / WP140Tri Inverter ~ 4 ~...
  • Page 5 Installation and operation manual WP 3. Installation et connections 3.1 Installation Your heat pump and your pool pump must be installed close to each other. Your heat pump must be placed outdoors and must follow the minimum spacings shown on the connection diagram. Your heat pump should be level and at least 15 cm above the ground.
  • Page 6 Installation and operation manual WP 3.2 Hydraulic connection Before carrying out any work, remember it is vital that all the valves are closed. As you can see from the connection diagram, you need to install a BYPASS valve (if you do not already have one) between the filtration system and the water treatment system (or discharge).
  • Page 7 Installation and operation manual WP Single-phase power Three-phase power connection heat pump connection heat pump Inverter Inverter 4. Start-up a) Checking the valves The BYPASS valve must be fully open. The inlet and outlet water valves must be closed. b) Clean the filter c) Valve settings Open your valves following the order and setting recommended below, and check for water leaks.
  • Page 8 Installation and operation manual WP Important: Leave the machine running for at least 10 minutes before changing the initial valve settings to get a difference between the inlet and outlet water temperatures of between 1°C and 3°C Remember to clean your filter every week to ensure the proper operation of not only the filter but also the heat pump.
  • Page 9 Installation and operation manual WP 5.2 Instruction and functions of the icons Name The button function ON/OFF Press to start /shut off the unit Click this button to view the unit state and the Parameter parameter Press to set the clock, the timer on or timer off. CLOCK When the timer was starting,the button is green Fault display...
  • Page 10 Installation and operation manual WP  Mode switch and target temperature setting a. Mode switch In the main interface, click mode button or inlet water temperature setting button, interface displays as follows: Click the refrigeration mode button , automatic mode or heating mode button then you can select the corresponding mode.
  • Page 11 Installation and operation manual WP a. The operation of time setting Click on the time Settings button , interface displays as follows: Click the value to set time directly, the click confirm button to save the Settings. For example: setup time: the 30-11-2016 16:00:00, input 30 11 16 16 00 00, the time change then click confirm button.
  • Page 12 Installation and operation manual WP Name Button Button function color Start: green Click this button to start or end Timing timing start setting function End: gray Click to set start time of the timing Timing on setting Timing end button Open: red Click this button to start or end timing end setting function End: gray...
  • Page 13 Installation and operation manual WP a. The silent button Click the silent button , the unit will enter the silent mode, and interface displays as follows: Click the silent button again, to exit the silent mode. b. Timing silent function setting Click timing silent button , and interface displays as follows: ~ 13 ~...
  • Page 14 Installation and operation manual WP Name Colur Function Click to use or unuse timing off Used: red Timing silent off function Unused: gray Click to use or unuse timing on Use: green function Timing silent on Unused: gray Timing silent start Click this button to set the timing time silent start time...
  • Page 15 Installation and operation manual WP If no failure, main interface displays static " ". When fault occurs, the fault icon will flash between the " " " ", the failure interface will record time, code, name of the fault. After troubleshooting, if you do not check the failure record, the main interface will display static "...
  • Page 16: Error Code

    Installation and operation manual WP Temperature curve automatically updates every one hour, and the curve record can be stored for 60 days. Start from the latest curve saved time, if power is off and curve data collecting time is less than one hour, the data in this period will not be saved. 5.3 Error code When the unit detects a failure, an error code is shown on the controller.
  • Page 17 Installation and operation manual WP Fault in the water outlet temperature sensor. Solution: -Check the calibration of the water inlet and outlet valves -Make sure the sensor wires are connected to the electronic board -Check that the sensor is correctly installed on the hydraulic heat exchanger -Check the condition of the sensor, make sure that the cable is not damaged or cut...
  • Page 18 Installation and operation manual WP 5.4 Integrated Wifi Kit You can independently connect the Wifi module and the remote control thanks to the double-link cable. Take control of your remote pool heat pump via the InverterTemp app to download from your Smartphone. Thanks to this option you can start, modify the operating parameters or stop your remote heat pump.
  • Page 19 Installation and operation manual WP Mobile InverterTemp App Heat pump Set up your Wifi module from your smartphone. After downloading the application, check that your phone is connected to the Wifi network. Open the application and press "+" to add a network connection. Select your Wifi and enter your password then press the arrow at the top right.
  • Page 20 Installation and operation manual WP How the application works Number Symbol Symbol Name Main Functions Parameters Enter the setting interface. Temperature Display of the water temperature of your pool. Menu Press to scroll down the menu. List of devices Return to the list of devices. Variation of the set temperature Press and move the palette to change your set temperature.
  • Page 21 Installation and operation manual WP a. ON / OFF Click on the menu and then on the "ON" tab to turn on your heat pump, a wave will appear to signal the operation of your heat pump. b. Operating mode To change the mode press the symbol below (see picture 1), or press simultaneously to scroll through the operating modes.
  • Page 22 Installation and operation manual WP d. How the timer works To enter the setting of the timer press the tab below (see photo 1). You can then enter your operating ranges and then confirm your programming as shown in the picture below (see photos 1, 2, 3 and 4).
  • Page 23: Temperature Curve

    Installation and operation manual WP g. Temperature curve To access this parameter, follow the following steps (see photo 1 and 2): The buoy corresponds to your current position. This buoy can be moved to visualize the evolution of your temperature curve. You must have at least 24 hours of operation before this function is active.
  • Page 24 Installation and operation manual WP 6. Maintenance and guarantee Maintenance is mainly about keeping your machine in good condition so that it does not give you any problems. 6.1 Maintenance to be done Clean the evaporator: Use a water jet, making sure to keep the jet in the direction of the fins, from top to bottom.
  • Page 25 Installation and operation manual WP Outside the guarantee period, or in the event of a failure not covered by the guarantee, the manufacturer may offer an on-site service. The customer must accept a quote in advance. No after-sales service interventions will change the guarantee period. 6.4 WP manufacturer’s guarantee The manufacturer's guarantee is for 5 years.
  • Page 26 Installation and operation manual WP Limitation: This guarantee is exclusive and replaces all other implied warranties of merchantability or fitness for a particular purpose and any other explicit or implied guarantees. The indemnifications provided for in this guarantee are exclusive and are Warmpac's only obligation, any other claim made by any person will have no effect.