Table of Contents 1. Application Notes 2. Safety Instructions 3. Precautions in Use 4. Installation and Commissioning 4.1 Installation Environment 4.2 Installation Site 4.3 Preparation before Use 4.4 First Power-on 4.5 Operation after Power Failure 5. Product composition and overview 6.
1. Application Notes Thank you for choosing and using Glacier products! For your safe and convenient use and reasonable maintenance of the equipment, please read the Operation Instructions carefully before use and keep it properly for reference The equipment operator can copy some chapters of this operation manual, but only for internal use, for example, to instruct the user how to deal with emergencies.
2. Safety Instructions When using this product for the first time, please pay attention to the meaning of the following warning signs and carefully read the safety precautions, so that you can use this equipment safely and correctly. Warning! Attention! Failure to observe the Failure to observe the precautions precautions may result in serious personal...
Page 5
It is forbidden to disassemble and modify this equipment without authorization, so as to avoid potential safety hazards. In this case, Glacier will not bear any responsibility for quality accidents. It is forbidden to put inflammable and explosive dangerous goods, strong corrosive acids, alkalis and other items unsuitable for the equipment in the equipment.
3. Precautions in Use ® Before putting the items into the equipment, please confirm that the temperature in the freezer storage chamber has reached the set value first, and then put the articles in batches. Every time you put in items, they shall not exceed 1/3 of the inner volume of the freezer storage chamber so as to prevent excessive temperature rise.
Before use, remove the small wire shelf and put it at the bottom of the cabinet (applicable to GL- RG-4M, GL-RG-12M, GL-RG-16M, GL-RG-23M). Installation of door handles (GL-RG-4M, GL-RG-12M, GL-RG-16M, GL-RG-23M). In order to install handles, the handles shall be placed together with accessories.
4.5 Operation after Power Failure 1. The equipment has a memory function for the set value. When the power is restored after power failure, the equipment will continue to operate before power failure. 2. Once the equipment is powered off, it requires 5 minutes before it can be switched on again, so as to avoid damaging the compressor.
Remote alarm Rs485 interface interface Power switch USB interface Door lock Test hole Cabinet Caster Adjust feet Door body Figure I GL-RG-4M Display panel USB interface Door lock Test hole Door handle Door body Cabinet Adjust feet Caster Figure II GL-RG-4M...
Page 10
Caster Adjust feet Figure III Display panel Printer (optional) (power switch on the back) USB interface Test hole Door handle Steel wire shelf Door body Cabinet Door lock Caster Figure IV...
Page 11
Display panel (power switch Printer (optional) on the back) USB interface Door lock Door handle Test hole Door body Steel wire shelf Cabinet Caster Figure V * Due to the improvement of products and model differences, the actual products may be different from the diagram. Please refer to the actual products! The diagram is only used for functional parts description.
6. Operating Instructions 6.1 Function Introduction This series of products include two control systems, based on which different adjustment methods apply. Please select the proper adjustment method according to the type of control system with the storage box you purchased. Printer (optional) Type A control panel 1.
Page 13
temperature display window, which displays the average temperature inside the cabinet in °C under normal operation; View ambient temperature: In the key lock state, press key, and digital tube displays the ambient temperature, and returns to normal display after 5 s without key operation, or pressing .
Page 14
2. Function setting of Type A control panel 1. After powering on, the equipment can enter the working state; 2. User parameter settings: To unlock: under normal operating conditions, long press for 3 seconds, the digital display code "000", input password "005"...
Page 15
5. Alarm display Alarm Code Error Description High temperature alarm Low temperature alarm Alarm for high ambient temperature Condenser overheat alarm Door opening alarm Power failure alarm Battery low alarm The recorder is not connected Battery low alarm Communication failure...
Page 16
(optional) (optional) Type B control panel 1. Function description of Type B control panel (Applicable to YC-130L) It is temperature display window, which displays the average temperature inside the cabinet in °C under normal operation; Different prompt characters can be displayed in the setting state (see below for details); b.Door opening indicator: When the refrigerator door is opened, the indicator lights up.
Page 17
In unlock state and parameter setting mode, press this key to display parameter values and parameter names. If the pressing time is longer than 3 seconds, save the settings and return to the normal interface. I. USB interface Automatic export of USB data: When the USB interface is connected to the USB flash drive, the buzzer of the recorder beeps once, displaying "ON", and PDF files of the data of the current month and the previous month are generated in the USB flash drive.
Page 18
4. Parameter display Menu Parameter Range Suggested Remarks item settings - Hardware version - - Software version - Temperature setting 0.0-10.0 Set value of high temperature alarm set+H; When H =0, High temp alarm is disabled; When the 0.0-10.0 alarm is over high temp alarm set, H1 will be displayed on the controller Set value of low temperature alarm set-L;...
5. Alarm display Alarm Code Error Description High temperature alarm Low temperature alarm Alarm for high ambient temperature Condenser overheat alarm Door opening alarm Power failure alarm Battery low alarm The recorder is not connected Battery low alarm Communication failure 6.2 Optional function 1.Printer Automatic printing:...
Page 20
2. Remote alarm terminal and RS485 interface The remote alarm terminal is installed on the back of the cabinet, and the alarm signal is output by the terminal. The load-bearing capacity of the terminal is 30V, 2A DC. Users can choose normally open, normally closed and common terminals according to their own needs.
7. Maintenance and Service Warning: In order to prevent people from getting electric shock or injury, please cut off the power supply of the equipment before ® any repairs and maintenance Make sure you don't inhale drugs or suspended particles around it when maintaining the equipment, otherwise it will ®...
8. Troubleshooting and Maintenance Services Any product may fail. Please observe the operation of equipment in time during use. If there is any abnormality, please check and handle it according to the following table first. If the abnormality can't be changed, please inform our service center in time, and we will serve you wholeheartedly to avoid losses.
9. Specifications Refrigerant Rated Rated Temp Effective Input Exterior Ambient Climate Weight Model and loading voltage frequency Range volume power dimensions temperature type (Kg) amount (v~) (Hz) (°C) (DxWxH) (mm) YC-55L 16 ~32°C R600a/14g 220~230V 2~8 °C 560X540X632 YC-55EL 16 ~32°C R600a/14g 220~230V 2~8 °C...
10. Packing List Certificate of Operation Manual Item Accessory package Conformity Quantity * The door handle accessory applies to: models YC-725L, YC-1015L, YC-1015EL and YC-1505L; * Keys apply to: models YC-55L, YC-55EL, YC-75L, YC-75EL, YC-130L ,YC-315L, YC-395L, YC-395EL, YC-400L , YC-525L , YC-725L and YC-1505L;...
Page 25
Note: Optional parts are included in the dash-dotted line, and some models are not equipped. Applicable to YC-315/YC-395L/YC-395EL/YC-400L/YC-525L/YC-725L/YC-1015L/YC-1015EL/YC-1505L Applicable to YC-130L * The technical data and electrical schematic diagram shall be subject to the nameplate on the product and the electrical schematic diagram in case of any improvement of the product design.
Need help?
Do you have a question about the GL-RG-4M and is the answer not in the manual?
Questions and answers