Advertisement

4.3.
HANDLE (fig.3) Place the handle into the central bracket situated on rear edge. Align the holes and pass the Ø8mm x 40 bolt through
both parts and secure with the M8 nut provided.
4.4.
PUMP (AK467dxp only) fig.4 The pump (1) comes attached to the pump bracket (2). Attach the pump bracket to the castor end
of the oil drainer in the position indicated above using the four M8 x 16mm bolts (3) provided. Each bolt must have a split lock washer
under the head and should be tightened using a 14mm spanner.
4.5.
Connect the sump outlet to the underside of the pump using the short length of tube provided. Slide the worm drive clips provided over the
tube first then push the tube onto the fittings and secure with the worm drive clips (fig.4.6).
Place the black filter screen into the shallow recess in the top of the pan.
ASSEMBLY
5. OPERATION
5.1.
PREPARATION
5.1.1.
When positioning the drainer ensure that there are no spills of oil on the floor both
prior to draining and afterwards. All spills should be cleaned up immediately to
prevent them becoming a slipping hazard.
5.1.2.
When positioning the drainer beneath the vehicle consideration should be given to
accessing the sump plug. If necessary loosen the plug before siting the drainer.
Remember that once the sump plug has been removed the escaping oil may be hot.
5.2.
COLLECTION OF WASTE OIL
5.2.1.
If unit has been used to drain a previous vehicle check to ensure that there is
sufficient spare capacity within the pan before you drain the next vehicle.
5.2.2.
Place the pan under the vehicle's sump, remove the sump plug and put to one side.
5.2.3.
Allow the engine to drain.
5.2.4.
When draining is complete, remove the pan and wipe up any spillage. Remember to
replace and tighten the sump plug using a new sump washer.
5.3.
EMPTYING OF WASTE OIL FROM PAN UNIT
WARNING! Dispose of all waste in accordance with local regulations.
5.3.1.
GRAVITY DISCHARGE (AK467D) Attach the discharge hose to the outlet valve
at the rear end of the drainer and secure it with the worm drive clip provided.
See fig.5. Place the other end of the pipe into a suitable container set at a lower
level than the drainer pan and open the outlet valve. When the drainer pan is
empty close the valve.
5.3.2.
MANUAL PUMP DISCHARGE (AK467DXP) Attach the discharge hose (see fig.4) to
the outlet connection on the top of the pump and secure it with the worm drive clip
provided. Place the other end of the pipe into a suitable container and proceed to
turn the pump handle clockwise until empty.
5.4.
After use thoroughly clean the exterior of the drainer and clear up any spills in the
work area. Store the drainer in a suitable clean dry place where it will not be a hazard.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
fig.3
01284 703534
Original Language Version
sales@sealey.co.uk
AK467D, AK467DXP Issue 3 (H,3,F) 26/02/19
fig.4
fig.5
www.sealey.co.uk

Advertisement

loading

This manual is also suitable for:

Ak467dxp