Download Print this page

Sealey SDH30.V2 Quick Start Manual page 2

Industrial dehumidifiers 30l

Advertisement

Cleaning and user maintenance shall not be made by children without supervision.
2. INTRODUCTION
Powerful dehumidification capacity, extracts up to 30 litres of water per day. Removes excess moisture from air, preventing build-up of mildew and
mould. Features auto-defrost function, which activates if the room temperature falls too low. Washable activated carbon air filter. Refrigerant is
environmentally friendly R290. May be connected to a drain hose for continuous operation. Mounted on castors for manoeuvrability.
3. SPECIFICATION
Model no.
Supply
Power
Dehumidifying capacity
Freezing pressure (max)
Steaming pressure (max)
Refrigerant
Global warming potential (rating)
Max. airflow
Working temperature
Working space
4. OPERATION
Efficiency of the dehumidifier is influenced by the air outside the room. For operating efficiency, try to avoid opening and closing the
windows and doors. For best performance, operate the dehumidifier within the usable operating temperature.
4.1.
OPERATION
4.1.1.
Plug the unit in to the mains socket, a beep will be heard when inserting the plug.
4.1.2.
Press the "ON/OFF" switch and the operation light will illuminate, the humidity display will light to display the previous set humidity.
The initial setting for humidity is 60%, after 3 seconds the display will show the current humidity.
4.1.3.
Press the humidity up or down buttons to adjust to the desired humidity required. If the required humidity is 3% below the current humidity
the unit will start automatically, if the set humidity is 3% more than the current humidity the dehumidifier will automatically stop.
4.1.4.
The unit has a memory function. Use the humidity up and down buttons to adjust to the desired setting and then press the memory
button to record the setting, each time the machine is switched on it will automatically run at the required setting.
4.1.5.
When setting the humidity to less than 30%, the unit will run continuously and the display will read "CO".
4.1.6.
To shut the dehumidifier down press the "ON/OFF" switch.
Note: If the humidity setting is greater than the current humidity the unit will not run.
WARNING! The fan motor and compressor must run for at least 3 minutes while dehumidifying.
DO NOT start the dehumidifier immediately after shutting down, allow 3 minutes before restarting.
8
fig.2
4.2.
DEFROSTING
4.2.1.
The evaporator within the dehumidifier frosts during the dehumidifying operation at a room temperature of approximately 15°C or less.
The defrosting device works automatically at an interval of approximately every 30 minutes for a duration of approximately 5 minutes.
The dehumidifying function will stop during the defrosting operation. Do not disconnect the plug or turn off the unit during the defrosting
operation.
Note: This dehumidifier does not have a cooling function, it produces heat during the operation and room temperature will rise by 1°C to
4°C. The temperature gets higher while it is operated in a closet, or similar. Furthermore, room temperature will rise because doors and
windows are closed and heat is produced from other appliances in the room and from sun radiation.
4.3.
EMPTYING THE WATER COLLECTION TANK
4.3.1.
During the dehumidifying operation, water is collected in the water collection tank. When the tank is full of water, the dehumidifier stops
operating automatically and the warning buzzer beeps twice. The unit will not restart until the water collection tank has been
emptied.
4.3.2.
Open the door and remove water collection tank from the dehumidifier by pulling it gently outwards by holding the sides of the tank
(fig.3).
© Jack Sealey Limited
SDH30.V2
230V ~ 50Hz
Max/Rated - 710W/570W
30L/Day 30°CRH80%
2.5Mpa
1.0MPa
R290/0.145kg
3
300m³/hr
5-32°C
78-104m³
Control Panel
Original Language Version
fig.1
SDH30.V2 Issue 1 30/11/20

Advertisement

loading

This manual is also suitable for:

Sdh30