3-7.

LCD SYSTEM ADJUSTMENT

Note 1 : The back light (fluorescent tube) is driven by a high
voltage AC power supply. Therefore, do not touch the
back light holder to avoid electrical shock.
Note 2 : When replacing the LCD unit, be careful to prevent
damages caused by static electricity.
Note 3 : Set the brightness to the center using the LCD BRIGHT
button.
[Adjusting connector]
Most of the measuring points for adjusting the LCD display are
concentrated in the following connector.
CN802 of the VC-197 board. Connect the measuring instruments
via the multi CPC jig (J-6082-311-A).
The following table shows the Pin No. and signal name of the
connector.
Pin No.
Signal Name
1
VR
3
VB
5
GND
7
HDB
9
FRP
[Power Supply Voltage]
Adjust the power supply voltage so that the battery terminal voltage
becomes 7.2 ± 0.1 Vdc .
[Video input signal for adjustment]
If stated as "10-step stair-step" in the signal column, input the 10-
step stair-step signal in the video input terminal as the video input
signal for the adjusting. Check that the input signal level is 1.00
Vp-p before adjusting.
Approx.
0.714V
Approx.
0.286V
Horizontal sync
Fig. 5-3-27.
Pin No.
Signal Name
2
VG
4
V-COM
6
SYNC
8
SAT
100IRE
1.00V

1. LCD Initial Data Input

Mode
Signal
Adjustment Page
Adjustment Address
Adjusting method:
1)
Set page: 0, address: 01, data: 01.
2)
Select page: D, and input the data in the following table.
Note : To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjusting remote commander
each time to set the data.
3)
Set page: 0, address: 01, data: 00.
NTSC
Address
4"
LCD
3C
08
3D
07
3E
03
3F
05
52
88
53
79
54
72
55
76
56
68
57
97
58
85
59
97
5A
7D
5B
7E
5C
69
5D
88
5E
00
5F
69
60
00
61
00
62
A1
( ): NTSC model only (GV-A500)
5-39
VTR stop
Arbitrary
D
3C to 3F, 52 to 62
Data
PAL
Remark
4"
LCD
08
08
03
Fixed value
05
Fixed value
86
66
60
79
73
9A
56
9A
7C
Fixed value
7D
Fixed value
60
Fixed value
86
60
(Fixed value)
60
Fixed value
B0
Fixed value
67
Fixed value
A1
Fixed value