Beghelli Zone Sensing Panel Instructions

Advertisement

When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1.
2. Disconnect power before performing work on electrical equipment.
3. Do not use outdoors.
4. Do not let power cords touch hot surfaces and do not mount near gas or electric heaters.
5. Equipment should be mounted in locations and at heights where unauthorized personnel will not readily
subject it to tampering.
6. The use of accessory equipment not recommended by Beluce Canada Inc., may cause an unsafe condition,
and will void the unit's warranty.
7. Do not use this equipment for other than its intended purpose.
8. Servicing of this equipment should be performed by qualified service personnel.
SAVE THESE INSTRUCTIONS!
9.
1. Secure the zone sensing panel to your wall or mounting surface.
2. Open the unit by pulling on the cabinet door (Figure 1). The hinged front cover can then be swung open and pulled
back, out of the way.
3. The cabinet supplied will be similar to that shown in (Figure 1) and may change slightly depending on the voltage of
the unit purchased.
4. Route wires into the cabinet utilizing the appropriate conduit and hub (supplied by others) to the terminal blocks.
Refer to (Figure 3) for typical connection or (Figure 4) for user-assigned DC Zones.
5. All connections are made within the ZSP utilizing heavy duty large gauge terminal blocks.
6. Make proper wiring connections within the cabinet as per diagram supplied (Figure 2)
7. Route wires and secure in place.
8. The cabinet purchased should not have AC power turned ON until on-site regulatory approval has been completed.
Beluce Canada Inc., 3900 14th Avenue, Markham, ON L3R 4R3 Tel: (905) 948-9500 Fax: (905) 948-8673
926000145

IMPORTANT SAFEGUARDS

INSTALLATION

Zone Sensing Panel (ZSP)
09/23/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Zone Sensing Panel and is the answer not in the manual?

Questions and answers

Summary of Contents for Beghelli Zone Sensing Panel

  • Page 1 SAVE THESE INSTRUCTIONS! INSTALLATION 1. Secure the zone sensing panel to your wall or mounting surface. 2. Open the unit by pulling on the cabinet door (Figure 1). The hinged front cover can then be swung open and pulled back, out of the way.
  • Page 2 AC to Emergency Unit is 120VAC. Figure 3 Zoned DC Outputs Designed to work with Beghelli Emergency Unit, which the TO DC Loads peak AC power consumption is less than 85VA. CAUTION: Disconnect Main Power and Zoned AC Before Servicing Unit!

This manual is also suitable for:

Zsp

Table of Contents