  • Page 1 OPERATION MANUAL FOR SHC-1000 MODEL...
  • Page 3: General Description

    The data and operating requirements stipulated in this Operation Manual are applicable to all the SHC series hydrogen generators. SHC series hydrogen generator is to electrolysis KOH liquid to produce hydrogen. There are many intelligent control equipments inside of equipment, easy and safety. Could meet requirement of many kinds of gas chromatograph and other instrument at home and abroad.
  • Page 4: Technical Parameters

    OPERATION MANUAL FOR SHC HYDROGEN GENERATORS 2.2 Technological Process Lye*-' Press·ure Contro Gas/wate r +' Syste m desiccator+ Se:paraton. 1 Tank+! • Output Pressure ,_.. Gaug,e..-• et+J I Hydrogen Ou Electrolysis cell Fig. t Technological Process Schematic Diagram Technical parameters Type SHC-1000 Output Volume...
  • Page 9: After Sales Service

    OPERATION MANUAL FOR SI-IC HYDROGEN GENERATORS disassemble ! stops 1. Overpressure. Pressure gauge indicates 3.lnstrument 1. Replace flow controller. electrolyzing above 0.45Mpa. 2. Discharge accumulated liquid. 2. Accumulated liquid in gas-liquid separator is excessive, floater reaches to upper limit of accumulated liquid.