T&D THERMON Terminator ZS-L-XP Installation Procedures Manual

T&D THERMON Terminator ZS-L-XP Installation Procedures Manual

In line splice/end termination kit

Advertisement

Quick Links

Tel: +44 (0)191 490 1547
Fax: +44 (0)191 477 5371
Email:
northernsales@thorneandderrick.co.uk
Website:
www.heattracing.co.uk
www.thorneanderrick.co.uk
Terminator
ZS/ZE
TM
In Line Splice/End Termination Kit
INSTALLATION PROCEDURES
For In-Line Splice Connection and End Termination Applications

Advertisement

loading

Summary of Contents for T&D THERMON Terminator ZS-L-XP

  • Page 1 Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk www.thorneanderrick.co.uk Terminator ZS/ZE In Line Splice/End Termination Kit INSTALLATION PROCEDURES For In-Line Splice Connection and End Termination Applications...
  • Page 2: Installation Procedures

    Terminator ZS/ZE INSTALLATION PROCEDURES Kit Contents . . . Order Separately for End Termination PETK Power and End Termination Kits (per cable) PETK-1 for BSX, RSX, VSX PETK-2 for KSX, HTSX, PETK-3 for FP, HPT Item Quantity Description Item Quantity Description Expediter Assembly Grommet Compressor...
  • Page 3 Terminator ZS/ZE INSTALLATION PROCEDURES Insert cable into expediter. If mounted on bot- Slide expediter toward pipe and route cable Locate bus connection (HPT and FP only) and tom or side of pipe, punch out weep hole. through support base entry. cable as shown.
  • Page 4 Terminator ZS/ZE INSTALLATION PROCEDURES Snap on crimp insulators Slide silicone caps over crimp insulators. Tighten cap securely. To remove cap, lift latch mechanism and Completed splice/tee kit. Make sure latch unscrew cap. mechanism is in the locked position. Three Cable Layout Tips Locate bus connection (HPT and FP only) and Insert three cables into expediter.
  • Page 5 Terminator ZS/ZE INSTALLATION PROCEDURES Wiring Details In-Line Splice T-Splice...
  • Page 6 Français Español Instructions d’installations des kits de jonction en lignes ou en T Kit empalme en línea / empalme en T. Instrucciones de instalación. Kit Terminator ZS-XP pour utilisation avec les rubans chauffants autorégulants de type RSX, Terminator ZS-XP para la utilización con cables calefactores autorregulantes RSX, TSX, VSX, TSX, VSX, BSX, HTSX, KSX, pour le ruban auto limitant de type HPT et pour les câbles à...
  • Page 7 THERMON . . . The Heat Tracing Specialists ® www.thermon.com European Headquarters Corporate Headquarters Tel: +44 (0)191 490 1547 • • For the Thermon office nearest you Boezemweg 25 PO Box 205 100 Thermon Dr. PO Box 609 Fax: +44 (0)191 477 5371 •...