Antenna heating system AHS-1022 Table of contents DESCRIPTION AND OPERATION OF THE PRODUCT ..........4 1.1 Description ..........................4 1.2 Technical specifications ......................4 1.3 The System components ......................6 1.4 Structure and operation of the System ..................7 1.5 Measurement instruments, tools and appliances ............... 8 1.6 Marking and sealing ........................
Page 4
Operating manual This operating manual (hereinafter – OM) describes composition, structure, and operation of Antenna heating system AHS-1022 (hereinafter – the System), as well as instructions on safe and correct operation of the System (intended use, technical service and current repair), and information on disposal of the System components (hereinafter –...
Antenna heating system AHS-1022 1 DESCRIPTION AND OPERATION OF THE PRODUCT Description AHS is applied at onshore facilities, as well on sea- and river-going vessels. The System ensures: automatic heating of antennae installed on open deck to protect them against low temperature using antenna heating units (hereinafter - AHU);...
Page 6
Operating manual Value Parameter with dome w/o dome Operating temperature, °C –52…+60 Limiting temperature, °C –60…+70 – Protection degree IP56 Weight, kg AHU-1 AHU-2 11.4 AHU-3 22.8 17.2 Ø х V L х H х W Overall dimensions, mm 370.0 х 440.4 277.0 х...
Antenna heating system AHS-1022 Table 5 – Main technical specifications of КР Parameter Value Total number of terminals Number of terminals to connect consumers Max. permissible voltage, V Max. permissible current, А Operating temperature, °C –15…+55 Limiting temperature, °C –60…+70...
Operating manual Table 7 – The System types Name Quantity, pcs. Type 1 Antenna heating unit AHU* 1…20 Control switchboard of antenna heating system CSAHS Multipurpose digital repeater DR-209М Junction box КР-124PW Type 2 1…20 Antenna heating unit AHU Control switchboard of antenna heating system CSAHS Junction box КР-124PW Type 3 1…20...
Antenna heating system AHS-1022 1.5 Measurement instruments, tools and appliances Control operation of the SC using integrated controls and LED light indicators. For more information on the controls and LEDs see section 2. Table 8 describes amount of consumables required for the TS.
Operating manual 2 DESCRIPTION AND OPERATION OF THE SYSTEM COMPONENTS Control switchboard of antenna heating system CSAHS is a painted metal cabinet. Figure 2 describes a general view of CSAHS with an integrated repeater. Figure 2 – CSAHS with an integrated repeater CSAHS is mounted on the wall through the mounting holes (Figure 2, position 9).
Page 11
Antenna heating system AHS-1022 Depending on size (see Table 2 and Figures А.1–А.3) and quantity of TH, AHU may have three types: ‒ AHU-1 – small, two THs; ‒ AHU-2 – medium, four THs; ‒ AHU-3 – large, four THs.
Operating manual – switch in top position – switch in down position Figure 4 – DIP-switch and ID number of AHU Multipurpose digital repeater DR-209М 2.3.1 Description Repeater is manufactured in painted metal casing; a port to connect power cable (Figure 5, position 3), and interface RS-422 serial ports to connect data cables (Figure 5, position 1 and 2) are located on the rear panel under the protective cover.
Page 13
Antenna heating system AHS-1022 Figure 5 – Repeater’s rear panel Controls and colour LCD screen 8" (resistive touch screen) to display visual data are on the front panel. Figure 6 describes a general view of the repeater’s front panel. Figure 6 – Repeater’s front panel Table 9 according to Figure 6 describes repeater’s controls.
Page 14
Operating manual Table 9 – Repeater’s controls Position № Control Description To enter settings menu or Menu ▲ To increase backlight brightness ▼ To decrease backlight brightness To exit settings menu or Exit To turn on (off) power * Depends on a type of repeater. Figure 7 describes connection diagram of the repeater.
Page 15
Antenna heating system AHS-1022 Figure 8 – Main screen view Version 0.1.1...
Page 16
Operating manual а) Figure 9 – Main screen view in case of error You can see main (основное питание) and standby (резервное питание) power indication in the bottom left corner of the main screen. If circle indication on the left is green, power is available, if red –...
Page 17
Antenna heating system AHS-1022 Figure 10 – Repeater’s main menu Menu «Оборудование» Figure 11 – Menu «Оборудование» Table 10 according to Figure 11 describes boxes and buttons of «Оборудование» menu. Version 0.1.1...
Page 18
Operating manual Table 10 – Menu «Оборудование» Position Name Description № AHU network address Имя AHU name AHU status («Инициализация» – initialization, «В работе» – Состояние operating, «Предупреждение» – warning, «Тревога» – alarm) Общ.Тест To test all connected AHUs for operation errors Общ.Сброс...
Page 19
Antenna heating system AHS-1022 Описание Parameter Default value Time (Т ) required for temperature increase inside dome when н Время на нагрев Т , с 600.0 THs are switched on. н If time is exceeded, alarm actuates Прирост температуры Temperature inside dome is to be increased by this value for за...
Page 20
Operating manual Menu «Настройки» Menu «Настройки» is used by manufacturer’s representative while providing primary settings of the Product. Figure 12 describes this menu. Figure 12 – Menu «Настройки» If power control board is included in the System, select port (Figure 12, box 1) of connection, and operation mode «...
Page 21
Antenna heating system AHS-1022 Menu «Сервис» Use «Сервис» menu to set up date and time, and while updating software version. Figure 13 describes this menu. Figure 13 – «Сервис» menu Button «Сервисный режим» (Figure 13, position 1) is used only by the manufacturer’s representative while providing primary settings.
Page 22
Operating manual Description of errors To view alarms and warnings, click any line of the detected error. The screen will display box with a description of error (Figure 14, position 2) and AHU parameters with a detected error (Figure 14, position 2), where t1 and t2 – temperature sensors data, Тэн...
Antenna heating system AHS-1022 Displayed notification Description of error Temperature has fallen lower than permissible Показания температуры вышли за limit установленные границы Temperature has risen higher than permissible limit Предупреждение Main power circle LED is illuminated with red No main power supply...
Operating manual 3 INTENDED USE Operational limitations Select an installation place in compliance with operational limitations (operating temperature and protection degree). All SC shall be grounded; all cables shall be insulated. Usage preparations 3.2.1 Safety features While preparing the SC for operation, check them visually and make sure there is no mechanical damage.
Page 25
Antenna heating system AHS-1022 ‒ make sure that the System is operating correctly. Disconnect the Product in the following order: ‒ transfer automatic circuit breakers of main and standby power supply (CSAHS) to down position; ‒ disconnect external main and standby power supply;...
Operating manual 4 TECHNICAL SERVICE OF THE SYSTEM General description Before performing the TS the staff shall familiarize with the Product structure and operation features, as well as observe this OM in full terms. In order to provide safe and reliable operation for the Product, the staff shall maintain all types of TS: ...
Antenna heating system AHS-1022 Table 14 – CL № 1. Visual check To be done Routine Man-hours 1) check completeness and appearance of the Product; mechanical damage, paint defects must be absent; marking plates shall be present; legends shall be read easily;...
Page 28
Operating manual Preservation and re-preservation shall be carried out in a clean room in normal climate conditions: ambient air temperature: + 25 ºС ± 10 ºС; relative air humidity: 45 % - 75 %; atmospheric pressure: 86 - 106 kPa (645 - 795 mm Hg). The room where long-term storage operations are carried out shall not contain any acids, alkalis and other corrosive substances.
Antenna heating system AHS-1022 4.4.3 Re-preservartion Re-preservation is carried out if polyethylene packaging was damaged or storage period of the Product is expiring without replacing silica gel. If the Product storage period is expiring (without replacing the silica gel), provide re-preservation.
Operating manual 5 CURRENT REPAIR 5.1 General instructions Control operation of the System according to Table 15. To provide diagnostics of the problems, see Table 16. 5.2 Safety features Only qualified personnel, examined in occupational safety may perform repair works. All SC shall be grounded before repair works.
Antenna heating system AHS-1022 Problem / defect Potential reasons To do Dome is damaged Replace the dome AHU is constantly operating (heating air) Wrong temperature settings Check preset temperature values/settings Problems in repeater operation Press a button to switch on (off) the...
Operating manual 6 STORAGE The Product must be stored in packaging inside areas complying with the required storage conditions (+5°С…+40°С) with the concentration of dust, oil, moisture and aggressive impurities in the air within the required limits for the working areas of production facilities.
Antenna heating system AHS-1022 7 TRANSPORTATION The Product must be transported in the Manufacturer's transportation package in closed means of transport. Types of shipment: - motor vehicle and railroad transportation in closed means of transport (covered cars, multipurpose containers); - air transportation (in sealed and heated compartments);...
Operating manual DISPOSAL New equipment, the parts of the Product damaged during operation, and any outage equipment must not be disposed as standard household wastes, since they contain the materials suitable for re-use. Decommissioned and non-used components of the Product must be delivered to a special waste disposal center licensed by local authorities.
OM. The Manufacturer will not consider damage claims in case of case violation of operating conditions. More information about warranty terms you can find on the official site of «NPK MSA», LLC, section «Support». Address and contacts of the Manufacturer's service centre: «NPK MSA», LLC 26E, Kibalchicha str., 192174, St Petersburg, Russia...
Operating manual APPENDIX А (MANDATORY) OVERALL AND INSTALLATION DIMENSIONS OF THE SC While installing AHU-1, AHU-2 and AHU-3 types with dome leave 150 mm free space from surface B to connect the Product. Figure А.1 – Overall and installation dimensions of AHU-1 Version 0.1.1...
Page 37
Antenna heating system AHS-1022 Figure А.2 – Overall and installation dimensions of AHU-2 Figure А.3 – Overall and installation dimensions of AHU-3 Version 0.1.1...
Page 38
Operating manual Figure А.4 – Overall and installation dimensions of repeater Figure А.5 – Overall and installation dimensions of КР Version 0.1.1...
Page 39
Antenna heating system AHS-1022 While installing CSAHS leave 120 mm free space from surface D to connect the Product. Figure А.6 – Overall and installation dimensions of CSAHS Version 0.1.1...
Operating manual APPENDIX B (MANDATORY) CONNECTION DIAGRAMS OF THE PRODUCT Figure B.1 – Connection diagram of CSAHS to main and standby power supply Figure B.2 – Connection diagram of two (and more) AHUs to power supply provided by CSAHS using KP Figure B.3 –...
Page 41
Antenna heating system AHS-1022 Figure B.4 – Connection diagram of two and more AHUs via CAN Figure B.5 – Connection diagram of AHU board to power control board Version 0.1.1...
Page 42
Operating manual Figure B.6 – Connection diagram of AHU power supply Figure B.7 – Table of connection Version 0.1.1...