Table of Contents: . . . . . .

Before Installing. . . . . . . . . . . . . . . . . . . . . 1
Steam Room Requirements . . . . . . . . . . . . 1
Typical Installation . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . 4
Generator Dimensions . . . . . . . . . . . . . . . . 5
Electrical Specifications . . . . . . . . . . . . . . . 6
Input Power Wiring . . . . . . . . . . . . . . . . . . 7
Wiring Diagrams . . . . . . . . . . . . . . . . . . 8- 10
Optional Autoflush Feature . . . . . . . . . . . 11
Check Out & Operation . . . . . . . . . . . . . . 12
Major Electrical Systems Test . . . . . . . . . . 12
Trouble Shooting . . . . . . . . . . . . . . . . 13- 15
Replacement Parts Diagram . . . . . . . . . . . 17
Replacement Parts List . . . . . . . . . . . . . . . 18
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . 19
Listed Steam Bath
Generator 777D
:
IMPORTANT NOTE
As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the
safe and efficient installation and operation of this generator.
These are two types of potential hazards that may occur during this installation and operation:
states a hazard may cause serious
injury or death if precautions are
not followed.
Page
Drain
Safety Valve
MODEL____________ Serial No._________________
ANSI
signals a situation where minor
injury or product damage may occur
if you do not follow instructions.
A Division of Sussman-Automatic Corporation
43-20 34th Street, Long Island City, NY 11101 • (718) 937-4500
1-800-767- 8326 • Fax: (718) 472-3256 • www.mrsteam.com
Western Regional Offices
9410 S. La Cienega Blvd., Inglewood CA 90301
1-800 72 STEAM (1-800 727-8326) • Fax: (310) 216-2944
®
_________
MODELS:
MS-65
MS-90
MS-150
MS-225
MS-300
MS-400
IMPORTANT NOTE
This highlights information that is especially
relevant to a problem-free installation.
MS-SUPER 1
MS-SUPER 2
MS-SUPER 3
MS-Super 4
MS-Super 5
MS-Super 6
:
Made in USA
PUR 101289
Rev. 4/01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MrSteam MS-Super 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sussman MrSteam MS-Super 1

  • Page 1: Table Of Contents

    A Division of Sussman-Automatic Corporation 43-20 34th Street, Long Island City, NY 11101 • (718) 937-4500 1-800-767- 8326 • Fax: (718) 472-3256 • www.mrsteam.com Western Regional Offices Made in USA 9410 S.
  • Page 2: Before Installing

    team Installation, Operation & Maintenance Manual Before Installing Read these instructions before installation or service.Although this MS steambath generator has been fully quali- fied for shipment by MR. STEAM, the following must be reviewed for proper, safe and enjoyable steam bathing. Verify that the model and accessories are correct, including incoming line voltage.
  • Page 3: Locating The Steam Generator Unit

    team Installation, Operation & Maintenance Manual Locating the Steam Generator Unit Select a location as near as possible to the steam room. Typical locations include: closet, vanity cabinet, heated attic or basement. Locate steambath generator within 25 feet of steam room. Do not install steambath generator inside steam room.
  • Page 4: Ms Super 4, 5, 6 Typical Installation

    team Installation, Operation & Maintenance Manual MS Super 4, 5, 6 Typical Configuration Installation Instructions for Models: MS-Super 4, MS-Super 5 and MS-Super 6 Install each unit as in a single installation. Connect the SMART/PLUS control to either unit per instructions supplied with the SMART/PLUS control. Using the interconnecting cable provided (PN 103608) connect the Black plug to the Liquid Level Control Board Terminal marked TANDEM in the same unit connected to the SMART/PLUS control.
  • Page 5: Installation

    team Installation, Operation & Maintenance Manual Installation Plumbing All plumbing shall be performed by a qualified plumber and in accordance with applicable national and local codes. • Use unions on all pipe connections. • Use only brass piping or copper tubing •...
  • Page 6: Plumbing Steam Outlet Water Supply Steam Head Generator Dimensions

    team Installation, Operation & Maintenance Manual Generator Diagram /---- -----\ Water Inlet Steam Outlet Safety Valve AutoFlush Drain Valve /----- ----\ /------------------------------------------------------------ -----------------------------------------------------------\ /--- ”---\ /----- ----\ /----------- ---------\ Clearance for /-------------------------- -----------------------\ / ------------------ ---------------- \ Element Service ------------------------------------- ------------------------------------ Side View Showing MS65-MS400...
  • Page 7: Electrical Specifications

    team Installation, Operation & Maintenance Manual Electrical All electrical wiring to be installed by a qualified electrician in accordance with local and national codes. Power Wiring See “Input Power Wiring” Diagrams (Page 7) Check power voltage. Use 240V rated-unit when supply is greater than 208V. (Most homes have 240V, 1PH service).
  • Page 8: Input Power Wiring

    team Installation, Operation & Maintenance Manual Input Power Wiring Ground lug Ground Models MS65 - MS400 (single phase wiring shown) Contactor L1, L2, Ground by field wiring Models MS Super 1 - MS Super 6 (single phase wiring shown) Ground lug Ground Fuse Fuse block...
  • Page 9: Wiring Diagrams

    team Installation, Operation & Maintenance Manual Wiring Diagrams Single Phase MS-65, MS-90, MS-150, MS-300, MS-400 Single Phase MS-Super-1, MS-Super-2, MS-Super-3 Three Phase MS-65, MS-90, MS-150, MS-225, MS-300, MS-400, MS-Super-1, MS-Super-2, MS-Super-3...
  • Page 10 team Installation, Operation & Maintenance Manual Single Phase Wiring Diagram with Smart/Plus control Installation Instructions for Models: MS-Super 4, MS-Super 5 and MS-Super 6 Install each unit as in a single installation. Connect the SMART/PLUS control to either unit per instructions supplied with the SMART/PLUS control. Using the interconnecting cable provided (PN 103608) connect the Black plug to the Liquid Level Control Board Terminal marked TANDEM in the same unit connected to the SMART/PLUS control.
  • Page 11 team Installation, Operation & Maintenance Manual Three Phase Wiring Diagram with Smart/Plus control Installation Instructions for Models: MS-Super 4, MS-Super 5 and MS-Super 6 Install each unit as in a single installation. Connect the SMART/PLUS control to either unit per instructions supplied with the SMART/PLUS control. Using the interconnecting cable provided (PN 103608) connect the Black plug to the Liquid Level Control Board Terminal marked TANDEM in the same unit connected to the SMART/PLUS control.
  • Page 12: Optional Autoflush Feature

    team Installation, Operation & Maintenance Manual Optional Autoflush System BOX CONTENTS: • AutoFlush Valve with Cord and Bushing • Nipple • Installation Instructions. The optional AutoFlush feature automatically drains the MrSteam system following each use. the stainless steel tank is flushed and remains empty until it is used again.A time delay allows the water to cool down (about two hours) before it drains resulting in a safe and gentle operation.
  • Page 13: Check Out & Operation

    team Installation, Operation & Maintenance Manual Check Out and Operation Turn on SMART CONTROL • Follow specific instruction sheet provided with controls. Steam will begin to appear in a (5-8) minutes at the steam head. • When system is equipped with a temperature control, steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point.
  • Page 14: Trouble Shooting

    team Installation, Operation & Maintenance Manual Trouble Shooting The information contained in this section is intended to aid qualified service personnel in the testing and repair of steambath generators. To avoid electric shock, disconnect generator from electric voltage supply. All servicing must be performed by qualified personnel only. _______________________________________________________________________ Problem Probable Cause...
  • Page 15 team Installation, Operation & Maintenance Manual Trouble Shooting ________________________________________________________________________ Problem Probable Cause Suggested Remedy _________________________________________________________________________ Unit is not heating Drain valve is open Close drain valve - Check for leaks _________________________________________________________ Unit is flooding See below _________________________________________________________ Liquid level control malfunction Check liquid level control for contactor operation* _________________________________________________________ Burnt out fuse(s)
  • Page 16 team Installation, Operation & Maintenance Manual Trouble Shooting _________________________________________________________________________ Problem Probable Cause Suggested Remedy _________________________________________________________________________ Too much steam (too hot) Unit is oversized Add room temperature control or air switch ___________________________________________________ Temperature control is set too high Set control to lower temperature _________________________________________________________________________ Fuse blows out or Fuse or circuit breaker is undersized...
  • Page 17: Five Easy Steps To Properly Size

    team Installation, Operation & Maintenance Manual It’s Easy to Select the Right Mr.Steam Model 1. Measure the Length, Width, and Height in feet of the steam enclosure to be used. Multiply the Length x Width x Height to get the basic room volume in CUBIC FEET (a) ___________________________________________________________________________________________________________ 2.
  • Page 18: Replacement Parts Diagram

    team Installation, Operation & Maintenance Manual MS Regular Models MS 65 - MS 400 (with Autoflush) shown with cover removed Transformer Liquid level Water feed Control board solenoid Power block Power supply Control connection knock-out Water feed Liquid level probe Water feed hose Steam outlet Safety valve...
  • Page 19: Replacement Parts List

    team Installation, Operation & Maintenance Manual Replacement Parts List _______________________________________________________________________ Part No. Description Product _______________________________________________________________________ 99178 Drain Valve (MS-Super 1 — Super 6) 99178MS Drain Valve (MS 65 — MS 400) 99297 Safety Valve 15PSI All models 100479 Water Feed Solenoid Valve w/filter All models 100477-1 Transformer 24VAC...

Table of Contents