Download Print this page

Salus SC824ZB Quick Start Manual page 2

Smart relay, low voltage

Advertisement

C
I
ONTROLS AND
NDICATIONS
LED
Function
AMBER (RED +
Power up
GREEN)
3 RED flashes
Network Search
Steady GREEN
Relay is Closed
No LED
Relay is Open
Long GREEN
Relay is Closed,
Short RED
no network
No LED
Relay is Open
Short RED
no network
Short GREEN
Special Function
Short RED
Mode
Long GREEN
Relay Closed,
Short AMBER
Identify
No LED
Relay Open,
Short AMBER
Identify
Terminal
Function
R (x2)
Power Input
C (x2)
Power Return
COM
Common relay contact
OUT
Relay output contact
P
I
AIRING
NSTRUCTIONS
• Prepare to add devices per your system's instructions.
• Power up the Smart Relay – Low Voltage (SRLV).
• When the SRLV is detected, follow your system's instructions to finish adding the switch to the system. You may
need to press the Multi Button to identify the switch.
U
S
R
SING THE
MART
ELAY
T
O
/O
URN
FF
N
• To toggle the SRLV (turn ON when OFF, or turn OFF when ON), press the Multi Button briefly.
R
J
N
ETRY
OINING
ETWORK
• When attempting to join a network, the device will stop trying after about 100 seconds. To try again, press and
hold the Multi Button for 5 seconds.
I
M
DENTIFY
ODE
• To initiate Identify Mode, press the Multi Button briefly twice in quick succession. The device will enter Identify
Mode and flash the LED accordingly.
R
F
D
ESET TO
ACTORY
EFAULTS
• To reset to factory default settings, press and hold the Multi Button for 10 seconds. The device will factory reset
and return to normal operations.
D
S
R
EFAULT
TATE OF
EMOTELY
See the Salus Smart Home app for other options for these parameters.
PARAMETER
Mode
LostConnectionState
PowerOnState
:
Status
:
– L
V
(SRLV):
OW
OLTAGE
A
P
CCESSED
ARAMETERS
DESCRIPTION
Enable/Disable local control of relay state
Relay state when connection is lost.
Multi-Button is always enabled at connection loss.
Relay state to be restored when powering up
Multi
Button
LED
Strip
Terminal
Action
Function
Short press
Toggle output
2x short press
Identify
Hold 5s
Attempt to join network
Hold 10s
Factory Reset
SPECIFICATIONS
Input Voltage
18-30 VAC
Input Current
30 mA,
50 mA max
Contact Voltage
30 VAC max
Contact Current
3 A max, resistive
Size (LxWxH):
45 x 45 x 20 mm
1.77" x 1.77" x 0.79"
Wall Box Size:
84 x 84 x 28 mm
3.31" x 3.31" x 1.10"
Wire Gauge:
12 - 24 AWG

Advertisement

loading