Page 1
ProAxis ™ Electric Profiling Bed and Pressure Area Care System Instruction for use and trouble shooting guide ________________________________________________________________________________ Instruction for use and trouble shooting guide ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 1/24...
Page 2
Fax 01978 660828 E-Mail: info@nightingalebeds.co.uk, Website: www.nightingalebeds.co.uk plus Nightingale Care Beds Ltd declares that the ProAxis ™ Electric Profiling Bed and Pressure Area Care System have been designed and manufactured to meet the following standards: CE for Medical Device Directive (93/42/CEE Class 1 medical device)
A specially developed Smart Control (optional) plugs into the bed and can be programmed to automatically adjust the mattress angles and thus provide additional pressure area care for patients at high risk of pressure ulcer development. Smart Control/Weight Indicator (optional) ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 4/24...
™ can achieve many positions by easy operation of a simple handset. Every function is motorised for minimising the physical effort required by nursing staff. The following positions are some examples; Chair Position Flat Trendelenburg Reverse Trendelenburg ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 5/24...
The Visco material is breathable and non-irritating, and helps to dissipate moisture and perspiration away from the body. It is common for modern mattresses to have anti-bacterial covers, but the Nightingale mattress now achieves the same standard internally. The Visco-Elastic material is temperature sensitive memory foam that consistently conforms to the patient’s body shape.
If the patient requires the provision of additional pressure area care then the Smart Control (optional) should be used [see Smart Control Operating Instructions] and not an A/P mattress. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 7/24...
™ Electric Profiling Bed is designed for persons over 127 kgs. The mattress support system has been designed and tested for use with a maximum patient weight of 318kg [700lbs/50 stone]; The safe working load is 353kg. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 8/24...
Page 9
Boards Safety Buffers Automatic Knee Break Split Side Rails Footrest Dropping Hinge CPR and Lockout Control Variable Height and Smart Control Trendelenburg Tilt Central Locking Brake System Linen Tray Smart Control Socket ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 9/24...
Chair Preset Position - To achieve a chair position with the platform profiled to the sitting position and the frame tilted down at the footend, the button marked Chair should be pressed. Flat Preset Position – To make the bed go flat, press the Flat button. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 10/24...
If a hand pendant button is pressed whilst locked out the Green LED on the pendant will flash, also the lockout red LED will flash. Press the relevant lockout button to restore function, the red LED will extinguish. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 11/24...
With the pedal depressed towards the head end the steering lock is activated to assist in moving the bed. For pressure relief, use the Smart Control (optional. See Smart Control Operating Instructions for instructions of use. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 12/24...
Due to the unique ProAxis Plus dropping hinge there is no fixed point on the mattress platform, this means that when the head section moves the thigh and foot sections move also.
Page 14
Home Screen Press BLUE function key below Smart symbol Accept previous settings Change Settings Exit to Home Screen If this is displayed the bed frame is tilted, press and hold to level. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 14/24...
Page 15
15 – 60 deg. start again Screen turns Once desired green and system angle is achieved is working. Time to press ACCEPT next movement is displayed. Press EXIT key to stop at any time. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 15/24...
Page 16
Used for a medium to high risk patient, only 30 degrees of movement and each of the 4 steps take 25 minutes. Used for high risk patients, 40 degrees of movement and each of the 6 steps takes 15 minutes. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 16/24...
This function is an Indication ONLY, it must NOT be used for clinical purposes i.e. calculating the amount of drugs to be administered. Simply follow the on screen instructions and press the buttons according to what is displayed on the screen. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 17/24...
Page 18
ProAxis ™ Electric Profiling Bed and Pressure Area Care System Instruction for use and trouble shooting guide ________________________________________________________________________________ ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 18/24...
Blood and bodily fluids High levels of available chlorine (10,000 parts per million) will inactivate most bacteria and viruses. Nightingale treat blood or body fluid spills with NaDCC solution at 10,000 parts per million available chlorine. Routing Decontamination NaDCC solution at 1000 parts per million available chlorine is recommended by the public health laboratory for routine decontamination.
Page 20
Important: If there is any doubt as to what solution of cleaning agent is required for the various cleaning procedures, the Infection Control specialist within the hospital should be contacted. If information is still unavailable, Nightingale beds can supply recommended solutions and data sheets. ProAxis Plus Operating Instructions 3.1...
It is recommended that every system is serviced annually to ensure the maximum length of service is provided and to meet Health and Safety requirements. Nightingale Care Beds Ltd will inform each purchaser by letter during the 12 month of each yearly period.
There has to be a minimum angle of backrest position will 15 degrees between the lowest and not set. highest positions for effective pressure relief. Keep pressing Raise until Set appears on the display. ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 23/24...
Page 24
Total after sales service Our aftersales and Helpline are always available. Nightingale Care Beds Ltd Unit 1 Ash Road South Wrexham Industrial Estate Wrexham LL13 9UG, UK 01978 660810 01978 660828 E-Mail: info@nightingalebeds.co.uk Website: www.nightingalebeds.co.uk ProAxis Plus Operating Instructions 3.1 Dated 18/05/11 24/24...