Summary of Contents for Meech 993R

  • Page 1 Operating Manual 993R Spark Free Generator Bar...
  • Page 3: Table Of Contents

    Products shown in this document may be covered by one or more patents, patents applied for and/or registered designs and/or trade marks. For further information please refer to our Head Office or visit www.meech.com. © Meech Static Eliminators Ltd., 27.10.17...
  • Page 5: Introduction

    Introduction Model 993R The Model 993R is a high performance Generator Bar for use with the Meech range of 50kV and 30kV high voltage DC power supplies. The 993R features resistively coupled emitter pins, rendering it near shockless and providing a controlled delivery of...
  • Page 6: Unpacking And Inspection

    Unpacking and Inspection Your Generator Bar was carefully packed at the factory in a container designed to protect it from accidental damage. Nevertheless, we recommend careful examination of the carton and contents for any damage. If damage is evident, do not destroy the carton or packing material and immediately notify the carrier of a possible damage claim.
  • Page 7: Operation

    Operation A typical charging system comprises one or more generator bars connected to a Meech high voltage power supply. The Power supply converts the primary electricity supply into a high voltage DC output. The generator bars are connected to this output by means of an EHT cable.
  • Page 8: Installation

    Installation Correct positioning of the bar is vital for efficient operation. The bar should be positioned directly opposite an earthed point/plate or a bar of opposite polarity. Non- conductive materials passing between the Generator bar and earth, or bar of opposite polarity, will be pinned together.
  • Page 9: Installation Caution Notes

    The High voltage system must be disconnected from the mains electrical supply before any adjustments to the position of the bar are made. If the unit continues to trip, contact Meech International Head Office or your local distributor. As this equipment may give an electrical shock if the pins are touched, the following...
  • Page 10: Technical Specification

    Technical Specification Model 993R Operating Voltage Up to 50kV D.C. Operating Current 0.5mA max Operating Polarity Either +VE or -VE. Max Temperature 60°C Weight 400g per m approx. Cable 2 metres in flexible conduit as standard, longer lengths can be specified when...
  • Page 11: Maintenance

    Maintenance Ionisers require periodic cleaning. During normal operation, dirt will build-up on the emitter pins and upon the body of the ioniser. This will cause a reduction in performance. Typically, weekly cleaning is sufficient. However, equipment used in some heavy contamination areas, such as gravure printing or where plastic fumes are present, may require daily cleaning.
  • Page 12: Repairs And Warranty

    Repairs And Warranty Your Generator Bar is warranted by Meech Static Eliminators Ltd to the original purchaser against defects in material and workmanship for one year after purchase. Should any malfunction occur, please return the bar directly to Meech Static Eliminators or your local agent.
  • Page 16: Meech Static Eliminators Ltd

    Meech International Meech Static Eliminators USA Inc Meech Elektrostatik SA Meech CE 2 Network Point 2915 Newpark Drive Kaiserbaracke 166 Gábor László utca 2 Range Road, Witney Norton, OH 44203 B-4780 St.Vith Budapest 1041 Belgium Hungary OX29 0YN, UK Tel: +44 (0)1993 706700 Tel: +1 330 564 2000 / 1 800 232 4210 Tel.: +49 (0)6555 3733 399...