Contents Foreword ..........................3 Availability .............................3 Formatting features in the document ......................3 Safety ........................... 3 Use for the intended purpose .........................3 Basic safety notes ..........................4 Qualification of personnel ........................5 Protective gear ............................5 Typographic features of warning notes ....................5 Formatting features for warnings of property damage ................5 Description ..........................
Certain text elements of this installation & operating TD steam drier/steam purifier or the TP air drier/air manual feature a specific typographic design. You purifier. The TD steam drier/steam purifier and...
Basic safety notes destroyed and hot or pressurised fluid may escape. Make sure that the equipment is always used within the admissible pressure and Risk of severe injuries temperature ratings. The equipment may become hot during You can find information on the pressure and operation.
Information on property damage or Typographic features of warning malfunctions notes Malfunctions will occur if the equipment is installed in a wrong position or with the flow DANGER pattern in the opposite direction of the fluid flow. This may result in damage to the equipment or Notes with the heading DANGER warn the installation.
Page 6
Nominal sizes 15 to 175 Nominal size 200 upwards No. Designation No. Designation Connection for steam or air inlet Connection for steam or air inlet Connection for steam or air outlet Connection for steam or air outlet Name plate Vent (only needed for work by the manufacturer) Connection for condensate outlet Name plate...
Test date Volume Task and function Purpose The TD steam drier/steam purifier is installed in steam systems. The equipment is used to separate water, suspended liquids and dirt from steam. The TP air drier/air purifier is installed in compressed air systems.
Application of European Directives Storing the equipment Please observe the following items when storing Pressure Equipment Directive the equipment: The equipment must conform to the requirements Do not store the equipment for more than 12 of the Pressure Equipment Directive (see months.
Meet the requirements for storage also when Your physical strength and on-site regulations and transporting the equipment. conditions determine what weight can be lifted and if support is required. Prior to transport seal off connections with sealing plugs. ...
Connecting the equipment Make sure that the pipe system of the plant is clean. DANGER Make sure that the equipment is free from foreign matter. Incorrectly connected equipment can Install the equipment in the pipe. cause fatal accidents or severe injuries. ...
Make sure that the equipment is fastened so Installation examples that its full weight is supported. The diagram below shows installation examples without (left) and with (right) stop valves. Make sure that the equipment is safely mounted and that all connections are made correctly. Operation ...
Maintaining the equipment After operation The equipment does not require any particular DANGER maintenance. If the equipment is used in contaminated Examine the equipment at regular intervals and areas there is a risk of severe injuries or check it for correct operation. death caused by harmful substances in or ...
Qualified personnel must have extensive experience For more information on suitable protective clothing with and a working knowledge of: and safety gear refer to the safety data sheet of the fluid in question. pertinent rules and regulations concerning handling hazardous substances DANGER ...
Disposing of the equipment Technical data CAUTION Pressure & temperature ratings Environmental damage may be caused by You can find the values for your equipment on the poisonous fluid residues. rating plate. Before disposing of the equipment make sure that it is clean and free of Weights fluid residues.
You can download the latest Declaration of Telefon +49 421 3503-0 Conformity or Manufacturer's Declaration at Telefax +49 421 3503-393 www.gestra.com or request it from the address E-Mail info@de.gestra.com below: www.gestra.com This declaration is no longer valid if modifications are made to the equipment without consultation...
Need help?
Do you have a question about the TD and is the answer not in the manual?
Questions and answers