ELECTRONIC CONTROL PANEL ONE THREE-PHASE MOTOR EQ400I Attention!! Read this manual carefully before starting the installation. N.B. - Casit does not accept any responsibility in case of failure to respect the norms in force in the country of the installation.
EQ400I ENGLISH 1. GENERAL INFORMATION This card is fitted with an on board 16A inverter to manage a 230/400 VAC three-phase motor. The inverter allows the setting of the acceleration and deceleration ramps of the motor, the maximum torque limit and the frequency modification (motor speed).
Page 3
EQ400I ENGLISH 4. CONNECTION AND SETTING UP OF THE CONTROL UNIT 4.1 CONNECTION AND WIRING LAY-OUT DIAGRAM 4.2 WIRING AND CONNECTIONS (SEE FIGURE ON PAGE 17) MAINS input: (1) Phase, (2) Neutral, (3) Earth – Flashing light 220 VAC: (4)-(5) – fixed/flashing, according to setting DIPSW6.
Page 4
EQ400I ENGLISH CONTROL UNIT SETTING UP ST SETTING Attention!! POSITION THE DIPSWITCHES TO OFF DURING THE UP PHASE EXCEPT FOR THE 8, ( “ON”. RESENT THAT MUST BE SET TO FUNCTIONS OF THE SWITCHES MOUNTED ON THE CARD Re-closing operating logic...
Page 5
EQ400I ENGLISH CHECK THE MOTOR RUNNING DIRECTION AND OPERATING COURSE LEARNING Attention!! THE MOTOR MUST HAVE A DELTA CONNECTION CHECK THE RUNNING DIRECTION of the MOTOR 1. Close the door. 2. Switch DIP 8 (Man Present) to OFF 3. With the Start (OPEN) and Close buttons, check the correct running direction and invert the motor polarity if necessary.
Page 6
EQ400I ENGLISH SETTING CONTROL UNIT WORK PARAMETERS press OK and until the display P2 appears Press BASIC MENU –DEFAULT PARAMETERS BOOST 6.1.1 Display: P2.10 – Initial thrust force Value expressed in %. Default setting = 15%. Press CO.MAX 6.1.2 Display: P2.11 – max torque Value expressed in % Default setting = 60%.
Page 7
EQ400I ENGLISH RIT. INV. Display: P2.27 - Motion inversion delay time in case of intervention of obstacle check, photocells, edges etc Value expressed in milliseconds Default setting = 100 ms Note: It is recommended not to set values less than 100 m/s to avoid violent mechanical stress...
Page 8
EQ400I ENGLISH DISPLAY FOR SHOWING AND PROGRAMMING THE CONTROL UNIT RESET display to start from the panel with the OK button pressed 0=Normal 1=Alarm Pagina 8 di 9 Rev. 00 del 30/11/2009...
(lightning, floods, fire, etc.), riots, vandalism, modifications to the environmental conditions of the installation site. Nor does the warranty cover parts subject to wear (batteries, oil etc.). Products returned to Casit for repair shall only be accepted carriage paid. Casit shall return the repaired product to the sender carriage forward. Otherwise the goods will be refused on receipt.