Summary of Contents for Lynxspring KANEsys JENE-PCLCD-R

  • Page 1 JENE-PCLCD-R Installation Guide...
  • Page 2 If you access a third party website mentioned in this guide, then you do so at your own risk. Lynxspring provides these links only as a convenience, and the inclusion of the link does not imply that Lynxspring endorses or accepts any responsibility for the content on those third-party sites.
  • Page 3: Table Of Contents

    10. TECHNICAL DATA............................20 11. RETURNING A DEFECTIVE UNIT........................21 12. CERTIFICATIONS ............................22 Federal Communications Commission (FCC)................22 RoHS CompliantDeclaration of Conformity................22 Declaration of Conformity ......................23 Revised 2/24/2011 Page ii Copyright © Lynxspring, Inc. 1210 NE Windsor Drive, Lee’s Summit, MO 64086 877-649-5969...
  • Page 4: Overview

    11. Returning a Defective Unit, page 20 12. Certifications, 21 Information and specifications published here are current as of the date of publication of this document. Lynxspring reserves the right to change or modify specifications without prior notice. The latest product specifications can be found by contacting our corporate headquarters or accessing www.lynxspring.com.
  • Page 5: Precautions

    • Do not handle the printed circuit board (PCB) without proper protection against static discharge. Use a wrist strap when handling PCBs. The wrist strap clamp must be secured to earth ground. ©2010 Lynxspring. All rights reserved. Page 4...
  • Page 6: Lcd Applications And Kit Review

    The JENE-PCLCD-R is intended to be used for multiple applications. Each application however requires an interface to JENEsys PC 1000/6000 or equivalent JACE 2/6 controller. For each application Lynxspring has designed a kit with a comprehensive list of materials to successfully install the JENE-PCLCD-R.
  • Page 7 (modem, for example), a reverse cable is used. Table 1 provides standard serial DB-9 pinouts. If a modem option card (JENE-PC-MODEMCARD) is installed, this port becomes disabled—except if rebooted with the mode jumper in the “Serial Shell” position. ©2010 Lynxspring. All rights reserved. Page 6...
  • Page 8 These LEDs provide a fixed on-time when data is detected on the port. If the receive LED is on constantly, this indicates a problem with the communications channel, such as a shorted wire or reversed wiring. ©2010 Lynxspring. All rights reserved. Page 7...
  • Page 9: Installing The Communication Option Card

    If they do not, the connector is not properly aligned. Press until the JENE-PC-LCDCARD card is completely seated. If you encounter any resistance, check that the pins are aligned properly. ©2010 Lynxspring. All rights reserved. Page 8...
  • Page 10 Step 10 Place the four screws through the battery bracket, end plates and into the standoffs on the JENE/JACE controller. Hand tighten the screws. See Figure 3 below. Figure 3 Step 11 If accessory modules were unplugged, plug them back into the JENE/JACE controller as before and secure. ©2010 Lynxspring. All rights reserved. Page 9...
  • Page 11: Installing The Shroud

    Snap the LCD onto the shroud. Note: To remove the LCD; simply press the appropriate tabs of the shroud and work the LCD and/or shroud from the base of the controller on both ends as needed. Figure 4 ©2010 Lynxspring. All rights reserved. Page 10...
  • Page 12: Mounting The Trim Ring

    LCD. If mounting distance is greater than 50 feet from the controller; you will be using the LCD-R-RS485 component which requires 2 wires and the shield connected ©2010 Lynxspring. All rights reserved. Page 11...
  • Page 13 Finally connect the RJ11 cable to the LCD, press and hold the power button to turn it on. Then place the LCD into the trim ring by simply snapping it into the trim ring using the four taps. Figure 7 ©2010 Lynxspring. All rights reserved. Page 12...
  • Page 14: Mounting The Lcd On Din Rail

    St e p 6 To keep this final assembly together, secure at both ends with DIN rail end- clips provided by the DIN rail vendor. This also prevents the assembly from sliding on the DIN rail. ©2010 Lynxspring. All rights reserved. Page 13...
  • Page 15: Mounting With Lcd Eyelets

    Install screws that have heads no larger than 1/4” in diameter. Step 3 Place the LCD such that the screws insert into eyelets on the back of the LCD and slide the LCD down. Figure 9 ©2010 Lynxspring. All rights reserved. Page 14...
  • Page 16: Power Options

    When using the LCD as a service tool; it is assumed the controller is preprogrammed and has installed the Lynxspring LCD module. If a communication option card is installed on the controller the LCD may be directly connected to it using one of the available coiled cables (part nos.
  • Page 17 LCD. When using batteries the LCD will turn itself off after 10 minutes of inactivity. Then turn the LCD on by pressing the power button. ©2010 Lynxspring. All rights reserved. Page 16...
  • Page 18: Un-Installing The Jene-Pclcd-R

    B. Disconnect DB9 Connector 5. Remove battery 6. Remove Blanking End Plate 7. Remove JENE-PCLCD-R card 8. Screw battery and blanking end plate back on to the controller 9. Replace standard JENE/JACE controller cover ©2010 Lynxspring. All rights reserved. Page 17...
  • Page 19: Listing Of Kit And Replacement Parts

    RJ11 to 9pin Female Adaptor when using the on-board RS- 9-MA09F11 port JENE/JACE controller provide communications to the LCD Interface Device. RJ11 to 9pin Male Adaptor when using the RS485/RS232 9-MA09M11 convertor at the LCD Interface Device. ©2010 Lynxspring. All rights reserved. Page 18...
  • Page 20 6' Coiled Black RJ11 Cable for LCD Interface Device TEL-6000-25K-RJ11 25' Coiled Black RJ11 Cable for LCD Interface Device MP-5FRJ11STWS-025 25ft Flat Satin RJ11 Cable for LCD Interface Device 8101-64150 50ft Flat Satin RJ11 Cable for LCD Interface Device ©2010 Lynxspring. All rights reserved. Page 19...
  • Page 21: Technical Data

    Storage Temperature ............-10◦F to 50◦F Shroud Dimensions......Narrow side: 4", Long side: 6.3", Height: 2.5" Material................UL94 Flame Class Trim Ring Outside Dimensions ............8” wide 6" tall Inside Dimensions ............5.9” wide 3.6” tall Material................UL94 Flame Class ©2010 Lynxspring. All rights reserved. Page 20...
  • Page 22: Returning A Defective Unit

    Prior to returning the unit, contact Lynxspring to obtain a return material authorization (RMA) number and other instructions. For proper credit on in-warranty unit, ship the defective module to Lynxspring within 30 days, provide information below: • RMA number provided by Lynxspring •...
  • Page 23: Certifications

    Any unauthorized modification of this equipment may result in the revocation of the owner's authority to continue its operation. RoHS Compliant ©2010 Lynxspring. All rights reserved. Page 22...
  • Page 24: Declaration Of Conformity

    98+A1:2001+ A2:2003 Measurement, control and laboratory use I, Terry Swope, hereby declare that the equipment specified above conforms to the above Directives and Standards. Place: Lee’s Summit Missouri, United States of America Position: President, Lynxspring, Inc. ©2010 Lynxspring. All rights reserved. Page 23...