--INSTALLATION INSTRUCTIONS--

Thank you for choosing a BREEZAIRE cooling unit. We believe our products are
the best on the market and will provide many years of trouble free service.
Please take a few minutes and read this entire instruction before beginning the installation.
Before removing the cooling unit from the box, please inspect for damage which might have been
incurred during shipping. If damage is found, notify the Freight Company immediately.
BREEZAIRE is not responsible for any damages incurred during shipping.
MODEL _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ SERIAL NUMBER _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
INSTALLED BY _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ DATE _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
While great effort has been made to provide accurate guidelines,
that enclosure construction, unit location and many other factors can affect the operation and performance of the unit. Therefore the suitability of the unit for a specific
enclosure or application must be determined by the customer and cannot be warranted by
WKS 4000 SERIES
(USA only)
BREEZAIRE
cannot warrant its units to properly cool a particular enclosure. Customers are cautioned
BREEZAIRE.

Advertisement

loading

Summary of Contents for Breezaire WKS4000 Series

  • Page 1: Installation Instructions

    8610 Production AvenuelSan Diego, California 92121l(858)566-7465lFax (858)566-1943lWWW.BREEZAIRE.COM --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe our products are the best on the market and will provide many years of trouble free service. Please take a few minutes and read this entire instruction before beginning the installation.
  • Page 2: Enclosure Construction

    Proper installation is critical to the performance, reliability and longevity of the system. For this reason, BREEZAIRE can only warrant the quality of the WKS components. The installation and proper operation must be warranted by the installer.
  • Page 3: Installation

    BREEZAIRE recommends the use of a licensed refrigeration technician to install the WKS systems. Installation of the unit's line set through a fire rated wall must be done in accordance with your local building inspector and building codes. If your installation cannot be performed in accordance with these instructions contact your dealer.
  • Page 4: Condensing Unit

    A condensate pump is required if the vinyl drain hose has any vertical rise, significant horizontal or near horizontal run. COOL AIR INTAKE CONDENSING UNIT BREEZAIRE Models WKS 4000 Fan/Coil 14.25...
  • Page 5 F Wiring the system: Wire the system in accordance with local code and the wiring diagrams. Electrical connections are made to the terminal strip in the fan/coil and the condensing unit. (Figure 3) Both the fan/coil and condensing unit requires a standard 110-volt, 60 Hz properly grounded electrical source. Each circuit must be rated for minimum amperes in accordance with sizing guide.
  • Page 6: Operation

    ENCLOSURE PROBLEMS BREEZAIRE is extremely proud of the quality and reliability of its products. Experience has shown that of the small number of problems encountered, the large majority are due to improper unit selection or enclosure construction.
  • Page 7 One way of discovering gross air leaks is to stand inside the enclosure with the lights off, allow your eyes to adapt to the dark and look for light showing through cracks in the walls or around the door. Also close the door on a piece of paper, if you can pull the paper through the door seal, it means air and moisture are also entering into your enclosure.