Download Print this page

Sealey AK481 Instructions page 2

Quick release three-way fill pistol type grease gun

Advertisement

4. OPERATION
WARNING! An empty grease cartridge or grease may be under pressure from the spring in the barrel, use caution when removing it.
4.1.
GREASE GUN LOADING
4.1.1.
Raise quick release mechanism cover (fig.1) and depress and hold the trigger.
4.1.2.
Separate the gun head from the grease gun barrel.
4.2.
CARTRIDGE LOADING
4.2.1.
Withdraw the plunger rod fully
4.2.2.
Remove plastic cap from end of grease gun cartridge, insert into barrel of grease gun.
4.2.3.
Remove seal from grease gun cartridge and mount grease gun head back onto the barrel.
4.2.4.
Depress the air vent valve (fig.2).
4.2.5.
Release the plunger rod using its tab, force the rod out and in a few times to eject air trapped in the grease via the air vent valve.
When grease comes out of the valve, the air has been discharged.
4.2.6.
Pump the grease gun handle until grease flows continuously. If it does not, depress the air vent valve again and use the plunger rod
to expel the trapped air.
4.3.
SUCTION LOADING
4.3.1.
Put open end of grease barrel into grease container to a depth of 50mm.
4.3.2.
Slowly pull back the plunger handle (fig.1) to pull the grease into the barrel. Lock the rod with the tab(fig.1).
4.3.3.
Shake the grease gun to settle the grease into the barrel.
4.3.4.
Mount grease gun head back onto the barrel, depress the air vent valve (fig.2).
4.3.5.
Release the plunger rod using its tab, force it out and in a few times to eject air trapped in the grease, from the air vent valve. When
grease comes out of the air vent valve the air has been discharged.
4.3.6.
Pump the grease gun handle until grease flows continuously. If it does not, depress the air vent valve and use the plunger rod to
expel the trapped air.
4.4.
FILLER PUMP LOADING
4.4.1.
Connect delivery mechanism from dispenser to the gun head filler plug (fig.2).
4.4.2.
Check that the bulk filler valves are compatible with gun filler plug.
4.4.3.
Wipe both the nipples clean of any dirt before filling.
4.4.4.
Connect the bulk filler valve to the grease bulk filler pump, keeping weight on the grease gun to keep it connected.
4.4.5.
Pumping becomes very hard once the grease gun barrel is filled.
4.4.6.
Depress the air vent valve to release any trapped air by releasing the plunger rod using its tab and pushing it in and out a few
times to eject air trapped in the grease, from the air vent valve. When grease comes out of the air vent valve, the air has been
discharged.
4.4.7.
Pump grease gun handle until grease flows continuously. If it does not, depress the air vent valve and use the plunger rod to expel
the trapped air.
4.5.
USING THE GUN
4.5.1.
The coupler has jaws which snap onto a grease nipple. Push the coupler straight onto the nipple to form a good fit.
4.5.2.
Operate the grease gun as square onto the nipple as possible.
4.5.3.
Once finished filling, tilt the coupler, twist and pull it off.
WARNING! DO NOT try to pull the coupler off straight.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
01284 703534
sales@sealey.co.uk
Original Language Version
www.sealey.co.uk
AK481
Issue 1
16/04/20

Advertisement

loading