AC-CPB
CPSET-M23
(A)
Function
The AC-CPB display and control units are
intended for access guarding with and without
muting. Depending on version, they can be
used to
reset the restart-interlock
display the OSSD state by illuminating the
button (after configuring with SafetyLab)
if applicable, display the muting state by
means of a LED indicator (A, B)
if applicable, evaluate 2 independent in-
duction loops as muting signals (B)
The 3 devices are designed for direct
connection to the 8-pin local socket of Safety
Light Curtains and Multiple Light Beam Safety
Devices of the COMPACTplus series. AC-
CPB are mounted to a hard guard using
supplied plastic strips
Attention!
These display and control units must be
mounted so that the entire danger zone
can be viewed from the installation loca-
tion and so that any switched-on muting
indicators can be clearly seen upon en-
try into the danger zone.
Features
Acknowledge and override via illuminated
button
Display of the muting state by LED indica-
tor
Simple mounting on hard guards by means
of plastic strips
Connection via M12 plugs / sockets
Leuze electronic GmbH + Co. KG, In der Braike 1, D-73277 Owen - Teck / Germany
info@leuze.de www.leuze.com
Dimensional drawings
(B)
(C)
Display and control units
AC-CPB-OPT (A)
AC-CPB-IND (B)
AC-CPB-RES (C)
Phone: +49 (0) 7021 / 573-0
Fax: +49 (0) 7021 / 573-199
2012/01