Overview
SLT Series
Specificationa
Emitter and Receiver Pylons
Input Power:
Output Circuit:
Fuses:
External Indicators:
Receiver Pylon
Emitter Pylon
Construction
Temperature Range:
Dimensions:
Beam Spacing:
Minimum Sensitivity
Without Blankin1:1:
Response Time:
Scanning Frequency:
120VAC
+/-
10% VAC @ 50-60 Hz, 12 watts max/pylon
24VDC(optional)
Safety Relays
Two force-guided self-checking N.O. relays in series rated at
4 AMPS@120VAC
Isolated (DRY) Normally Open contacts.
130VAC maximum
Auxiliary Relay
N.O. or N.C.
Solid State Output
Two PNP outputs rated at 500mA each. The solid state outputs must
never be placed in series or parallel and are not to be used as the final
switching element(s).
Power: Surface mount replaceable 1A Slow Blow
1)
GREEN = Output Relay contacts closed (OK)
2)
RED = Output Relay contacts open (NOT OK)
3)
Diagnostics Display (single dig it alphanumeric)
RED = Sync channel alignment indicator
(11-1/2"
down, viewable only from inside unit)
Aluminum extrusion with steel end
poly cargonate lens. NEMA 4 (without blanking keyswitch).
32
°
to 1200 F
See Dimensional Information
3/4" (19mm)
1-1/4" (32mm)
< 30 milliseconds (all lengths)
3.6 Khz
2
--11--11--
caps,
m ounting
brackets,
and replaceable