External output terminals
Name
Hold end signal
Trouble output
Welding counter completion
output
Production counter completion
output
or
Step-up completion output or
Signal-up completion output
Pressure control output
Welding current interlock output
I (
SOL
Solenoid valve 1
SOL
II
(Solenoid valve 2)
24 VDC output
100 VAC output
* As for "Switch means", see section "Applied function: Selecting functions" for details.
• An output that is turned on for 150 msec. (0.15 s)
after the end of the hold time.
• This signal does not output when the trouble output
is on.
• Normally open contact
Load at resistance load: 24 VDC, 30 mA or less.
• An output that is turned on when a major trouble
occurs.
• Input the "Trouble reset input" to reset.
• It is factory set to "normally open" at shipment.
Load at resistance load: 24 VDC, 30 mA or less.
• An output that is turned on when the counter
reaches the preset welding count.
• Input the "Welding counter reset input" to reset the
counter to zero.
• Normally open contact
Load at resistance load: 24 VDC, 30 mA or less.
<When is set to "Production counter completion
output" mode>
the signal is turned on when the counter reaches
the preset number of products.
• Input the "Production counter reset input" to reset to
zero.
<When it is set to "Step-up completion output" mode>
the signal is turned on when "step-up" or "Signal-
up" (depending on the current incremental method
setting) is completed
• Input the "Step-up reset input" to reset the counter
to zero.
• Connect the power amplifier when the proportional
control valve (optional) is applied.
• An output to interlock welding current with another
unit.
• An output that is turned on while welding current is
flowing (from the start of the upslope to the end of
the down-slope.)
• The signal does not output when the "Current off" is
selected.
• Normally open contact
Load at resistance load: 24 VDC, 30 mA or less.
Connect the solenoid valve for pressing (100 VAC)
)
• As they are SSR output, 100 VAC is output even in
ready state.
An auxiliary power for an external device.
Make sure to use it at 100 mA or less.
Do not use it to any device that generates noise.
Polarity: 44 (positive), 14 (negative)
An auxiliary power for an external device.
Make sure to use it at 0.2 A or less.
Do not use it to any device that generates noise.
Function
Basic operation
Switch means
-
JP1
(To select a contact type.)
-
JP2
(To select a counter
completion output type.)
DIPswitch: DPSW1-10
(To select a current
incremental method.)
DIP switch 2-1
(To use this function)
-
-
-
-
-