Microprocessor based Gas Detector for Carbon Monoxide (CO)
2 Alarm Levels
Visual and Audible Signalization of
Activated Alarm Levels
2 SPDT 5A/250V Output Relays
Electrochemical Gas Sensor
I. APPLICATION
The single-channel gas detector "DG510/CG" is purposed for signaling anytime, when
concentration of carbon monoxide (CO) exceeds permissible limits. It is applicable in
underground garages, automobile workshops and engine testing stands, chemical industry
factories and other areas, where toxic CO concentrations can be found. The sensor element is
an electrochemical cell, which eliminates any possibility of false alarms. The gas detector
has a standard range of 0÷350 ppm CO (up to 1000 ppm on request) and two alarm levels –
pre-alarm "ALARM 1" and alarm "ALARM 2" – connected with 2 SPDT 5A/250V output
relays. If the concentration of CO exceeds the set pre-alarm level an integrated buzzer starts
emitting repeated short beeps, the LED "ALARM 1" is lighted up and the output relay "REL
1" is activated. The relay output may operate a ventilation system in order to clear the air in
the room. When the concentration drops with 10% below the set pre-alarm value, the output
relay is deactivated. If despite the ventilation the CO concentration exceeds the set alarm
level, the buzzer starts emitting a continuous signal, the LED "ALARM 2" is lighted up and
"REL 2" output relay is activated, which can operate a siren, a semaphore system, barriers,
alarm lights or other systems to restrict the access of people to the dangerous area until the
concentration drops below the alarm level. To suit customer's needs there is an option to
adjust the concentration values for pre-alarm and alarm levels via switches and a button,
placed on the circuit board.
series "GAS ALARM DG510/CG"
Tel. +359.2.974 62 36, 974 62 37, 974 62 38; Fax: +359.2.974 62 04
Web Site: http://www.deltainst.com;
DELTA INSTRUMENTS Ltd.
23 A. Saharov blvd., Mladost 1, 1784 Sofia, Bulgaria
E-mail: delta@deltainst.com

Advertisement

loading

Summary of Contents for Delta DG510/CG

  • Page 1  Electrochemical Gas Sensor I. APPLICATION The single-channel gas detector “DG510/CG” is purposed for signaling anytime, when concentration of carbon monoxide (CO) exceeds permissible limits. It is applicable in underground garages, automobile workshops and engine testing stands, chemical industry factories and other areas, where toxic CO concentrations can be found. The sensor element is an electrochemical cell, which eliminates any possibility of false alarms.
  • Page 2: Technical Specifications

    II. TECHNICAL SPECIFICATIONS Power Supply 230V, 50Hz Detected Gas Range 0-350 ppm Sensor Electrochemical cell Pre-alarm level “ALARM 1” 50 ppm CO - adjustable Alarm level “ALARM 2” 150 ppm CO - adjustable Pre-alarm output signal “REL 1” SPDT relay, 5A/250V Alarm output signal “REL 2”...
  • Page 3 IV. OPERATING INSTRUCTIONS The gas detector “Gas Alarm DG510/CG” is calibrated with a standard gas mixture and by correct mounting no additional settings and calibration should be necessary. After switching on the power supply follows an initial activation process of the sensor for 1-2 min.
  • Page 4 Button Fig. 1 Switches B C D E ALARM 1 ALARM 2 0000 300ppm CO 300ppm CO 0001 275ppm CO 275ppm CO 0010 250ppm CO 250ppm CO 0011 225ppm CO 225ppm CO 0100 200ppm CO 200ppm CO 0101 175ppm CO 175ppm CO 0110 150ppm CO...
  • Page 5: General Conditions

    V. GENERAL CONDITIONS 5.1. “DG510/CG” gas detector may be used only in applications, approved by its manufacturer - DELTA INSTRUMENTS Ltd. 5.2. Test and calibration have to be made every 12 months. The test overall performance will be ensured in a best way through a periodical maintenance servicing contract with the manufacturer.