HydroTherm DYNAMIC /X8 Installation Manual

Plumber's condensed

Advertisement

DYNAMIC /X8
PLUMBER'S CONDENSED
INSTALLATION GUIDE
150mm
• This unit is designed for external operation only and requires a continuous supply of air to operate efficiently.
• Avoid installation in areas where falling debris, such as leaves, is prevalent as this may result in air vents being
blocked or the unit being damaged.
• Avoid placing the system in locations with multiple walls or structures.
• Always maintain optimum perimeter from all structures.
• The unit should be installed on a concrete plinth or stable structure capable of sustaining weights in excess of
450kg.
• A minimum dimension of 600mm x 600mm is required. Please ensure that all four feet are supported by the
base being used otherwise warranties may be voided.
• The system is to be installed level to ensure that the condensation drainage is not impaired.

1. LOCATION SELECTION

FRONT SIDE
300mm
600mm
HYDROTHERM UNIT
150mm

2. BASE

SUPPLIED CONTENTS
CONDENSATE
DRAINAGE
ELBOW (connected)
OWNER'S MANUAL
OWNER'S
MANUAL
Welcome to the future of hot water.
DYNAMIC /X8
PTR
LEFT SIDE
300mm
pg.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DYNAMIC /X8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HydroTherm DYNAMIC /X8

  • Page 1 SUPPLIED CONTENTS DYNAMIC /X8 CONDENSATE DRAINAGE ELBOW (connected) PLUMBER’S CONDENSED OWNER’S MANUAL OWNER’S INSTALLATION GUIDE MANUAL Welcome to the future of hot water. DYNAMIC /X8 HYDROTHERM UNIT 1. LOCATION SELECTION FRONT SIDE LEFT SIDE 300mm 300mm 150mm 600mm 150mm • This unit is designed for external operation only and requires a continuous supply of air to operate efficiently.
  • Page 2 3. PLUMBING CONNECTIONS 620mm Cold water supply outlet (3/4” female thread) Hot water outlet (3/4” female thread) Condensate drainage elbow* PTR relief valve* (1/2” female thread 850kPa) Electrical cable Tempering Valve (high performance recommended) (if required by council - 700kPa) Pressure Reduction Valve (PRV - 500kPa) Non-return Isolation valve...

Table of Contents