Page 1
® TORRENT HARD SURFACE CLEANER 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. DANGER: High pressure may cause sever injury. Always wear safety glasses. NEVER direct the spray towards yourself, other people, or pets.
IMPORTANT SAFETY INSTRUCTIONS This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops, and offi ces other than normal residential housekeeping purposes. When using any electrical appliance, basic precautions should always be followed, including the following: NOTE: Read all instructions before using this machine.
Record the serial number and model of your new extractor here: (and be sure to register your purchase to active your warranty -- go to www.usproducts.com) Serial Number: __________________ Model: TORRENT-120 Purchase Date:_____________ Write the name and phone number of your distributor:...
AND the switch is on the PRESSURE ON position. U.S. PRODUCTS High Pressure Pump Switch (4): Turns on/off the high pressure (400-1200 psi) pump. Dual Cord Sensor Light (5): The green light will turn on only when the two power cords are plugged into separate circuits.
RECOVERY TANK: (refer to Figure 2) Pre-Filter: 800 micron polyester mesh bag with quick-change cord lock. This fi lter hangs inside the tank from the recovery hose inlet piping. Check the pre-fi lter before operation and clean as required. Stainless Steel Filter: 50-mesh fi lter screws into base of recovery tank. Inspect daily and clean as needed. Float Valve: Located on the back wall in recovery tank, it automatically controls dump pump when switch is in ON position.
OPERATION 1. Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make sure hoses are in good condition and the spray nozzle(s) is tight. 2. Connect direct water feed hose (supplied with chemical feed and back fl ow preventer) to the water supply and to the machine.
Page 7
AUTO-FILL: Without Chemical Injection: Simply connect one end of the water supply hose to a convenient water supply, and connect the other end to the water inlet fi tting on the machine. NOTE: hot water cleans better than cold water. When all set-up and ready to begin cleaning, turn on the water supply.
PUMP MAINTENANCE: Oil Change: The fi rst oil change is required after the fi rst 50 hours of use. Impurities will get into the oil during the break-in phase, and it is necessary to change the oil to remove the contamination that can lead to premature pump wear.
TORRENT PUMP MAINTENANCE SCHEDULE It is critical that you maintain your pump properly in order to get the performance and longevity that it can provide. Change the oil in your pump after the fi rst 50 hours of operation, then follow this maintenance schedule. AS NEED- TASK DAILY...
Need help?
Do you have a question about the TORRENT-120 and is the answer not in the manual?
Questions and answers