  • Page 1 H4 ES HEAT TREATMENT SYSTEM USER MANUAL...
  • Page 2: Table Of Contents

    Delivery inspection ..........................5 Product Overview ..........................5 Bedbug Decontamination – Standard Operating Procedure .............. 6 Installation ............................7 To Use H4 ES, menus and operation ....................8 Alarms ..............................15 Service Reminder ..........................16 Maintenance and service ........................16 Filter inspection and cleaning......................
  • Page 3: Intended Use

    Intended use The Heat Treatment System H4ES, containing an insulated tent with floor insulation and collapsible frame and the intelligent H4 ES heater is developed and intended for indoor heat treatment of insect infested material such as beds, sofas and clothing.
  • Page 4: Manufacturing Directive

    Corroventa Avfuktning AB. Any comments on the contents of this document shall be sent or addressed to:...
  • Page 5 Children must not be allowed to play with the equipment. Cleaning and maintenance must not be performed by children without supervision. Electrical installations made in connection with the installation of the H4 ES shall be made by authorized personnel in accordance with local and national regulations.
  • Page 6: Delivery Inspection

    Delivery inspection Heat Treatment System H4 ES is delivered with the following items included: H4 ES 1 pc Tent temperature sensor assembly 1 pc Tent 1 pcs Collapsible tent frame 1 pc Floor insulation mats 2 pcs Product Overview Below pictures present H4ES ES with all its external features and controls.
  • Page 7: Bedbug Decontamination - Standard Operating Procedure

    Application of heat using H4ES Mattress covers (recommended) Climb Up Traps (recommended) Application of pesticide (recommended) *Terms and conditions according to specified service should be granted. Follow up Inspection and/or contact with customer by other media © Corroventa Ltd. 2017.10 6 (22)
  • Page 8: Installation

    16. Connect both power cables to the machine to two separately fused power outlets of 230 VAC 50Hz, max 16A. 17. Flip the power switch to the left of the control panel to start the machine. © Corroventa Ltd. 2017.10 7 (22)
  • Page 9: To Use H4 Es, Menus And Operation

    To Use H4 ES, menus and operation The H4 ES has an easily understood user interface with a display and five push buttons. The two larger buttons on the respective sides of the display are used to select between the different menus –...
  • Page 10 The fan will button will stop that too. continue to run for a while after the heaters are switched off. © Corroventa Ltd. 2017.10 9 (22)
  • Page 11 The H4 ES will, when started, go into Heat Up and remain there until target temperature is reached with all four temperature sensors inside the tent. When target temperature is reached, the machine enters the Processsing phase where it will strive to maintain target temperature. If set to Manual mode, the machine will continue this operation until manually switched off.
  • Page 12 This menu is only presented when a SuperVision® Gateway is connected to the machine. When used with the H4ES, as external sensor nodes are not used with the SuperVision, only the first row, the signal quality, is of interest. © Corroventa Ltd. 2017.10 11 (22)
  • Page 13 Remember that the machine must be started before leaving the site in order for the Timer to take effect, the screen showing the text TIMER STANDBY. © Corroventa Ltd. 2017.10 12 (22)
  • Page 14 This screen presents the hour counters. At the top, the resettable work counter is presented, followed by the date at which the counter was reset. After the date, the number of hours elapsed since this © Corroventa Ltd. 2017.10 13 (22)
  • Page 15 The alarms presented need not be erased by the user. Instead, as soon as the machine detects that the functionality is again in place, the alarm will disappear automatically. © Corroventa Ltd. 2017.10 14 (22)
  • Page 16: Alarms

    If not and if it remains, please contact service technician. Failed to save the statistics Internal error. If it remains, please contact service technician. Failed to save the event log Internal error. If it remains, please contact service technician. © Corroventa Ltd. 2017.10 15 (22)
  • Page 17: Service Reminder

    Filter inspection and cleaning The process air filter shall be inspected and, if necessary, cleaned before each new cycle. Accessories and consumables The following articles are available as accessories and consumables to the H4 ES machines: Article number Name 1003493...
  • Page 18: Fault Finding

    Replace or repair sensor assembly. damaged. Note: If one or several of the temperature sensors have failed, the machine will continue to operate until manually switched off, regardless of whether it is in Auto or Man (Manual) mode. © Corroventa Ltd. 2017.10 17 (22)
  • Page 19: Technical Data

    Technical data H4 ES Typ LAF 50 LAF 50E LAF 50E2 LAF 100 LAF 100E LAF 150 LAF 150E Voltage 230 VAC / 50 Hz Rated power (W) Power cable 1: 2100W Power cable 2: 2200W Air volume m3/h Height x width x length (mm)
  • Page 20: Illustrated Installation Description

    3. Unfold the tent and place it on the insulated floor mats. Take care to place the door in the intended direction. 4. Use the straps at the respective top corners of the tent to secure them to the tops of the telescopic frame legs. © Corroventa Ltd. 2017.10 19 (22)
  • Page 21 7. No material is placed beyond the red indicators on the floor, leaving 20 cm free so that the air can circulate. Leave space also by the ceiling. Leave this space free so that air can flow freely by the tent perimeter. © Corroventa Ltd. 2017.10 20 (22)
  • Page 22 14. Open the sensor cable gland in the tent, pull the sensor assembly connector through and then connect it to the machine. Close the gland. © Corroventa Ltd. 2017.10 21 (22)
  • Page 23 Resume to start with previous settings. Verify the target temperature setting and, for Auto mode, the process time setting. 19. Verify that the SuperVision symbol is visible at the top of the screen and that the Gateway has reception. © Corroventa Ltd. 2017.10 22 (22)
  • Page 24 In emergency situations and during flooding, CORROVENTA LTD Corroventa’s customers have access to one of the largest rental parks in Europe. Unit 47, Melford Court, Hardwick Grange, Warrington All our products are manufactured in Bankeryd, Sweden.