Download Print this page

Hyundai GR8 Technical Service Bulletin page 7

Battery tester/diagnostic charger

Advertisement

GR8 DIAGNOSTIC TESTER/CHARGER TOOL AND BATTERY WARRANTY POLICY
SUBJECT:
Connect only the Charger unit's large clamp set to the vehicle's battery making sure that the
5.
black clamp is connected to the battery negative "-" terminal and the red clamp is connected
to the battery positive "+" terminal. GR8 display will warn if you have connected it
backwards.
6.
Perform the following instructions showing the GR8 screens (as shown from left to right of
each row) that will occur when a "Good Battery" result is reached after charging:
Press YES to start charging
Diagnostic charge is in progress
Good Battery condition reached
NOTICE
If the Diagnostic Charge results in "Good Battery", attach both Battery Test
printout of the "Charge & Retest" result and the Diagnostic Charge "Good
Battery" result per example of "Printout #B" on page 9.
TSB #: 18-EE-003
Connect large clamps
Charge status being displayed
Full Charge Complete
Page 7 of 10