HANYOUNG NUX SSR-2C Series Instruction Manual page 2

2-wire break alarm output solid state relay

Advertisement

SSR-2C
2-Wire Break Alarm Output Solid State Relay
INSTRUCTION MANUAL
Thank you for purchasing Hanyoung Nux products. Please read the instruction
manual carefully before using this product, and use the product correctly.
Also, please keep this instruction manual where you can view it any time.
▍ Safety information
Please read the safety information carefully before the use, and use the product correctly.
The alerts declared in the manual are classified into Danger, Warning and Caution according to their importance
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury
WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage
DANGER
• The input/output terminals are subject to electric shock
risk. Never let the input/output terminals come in contact
with your body or conductive substances.
WARNING
• Please read the safety information carefully before the use,
and use the product correctly.
• If there is a possibility that a malfunction or abnormality of
this product may lead to a serious accident, install an
appropriate protection circuit on the outside and plan to
prevent accidents.
• Please supply the rated power voltage, in order to prevent
product breakdowns or malfunctions.
• To prevent electric shocks and malfunctions, do not supply
power until the wiring is completed.
• Please disassemble the product after turning OFF the power.
• Any use of the product other than those specified by the
manufacturer may result in personal injury or property
damage.
• Please use this product after installing it to a panel,
because there is a risk of electric shock.
▍ Suffix code
Model
Code
SSR-
Solid State Relay
Phase
2
Single-Phase
C
2 contacts
25
25A
Rated load current
40
40A
Operating load voltage
2
90 - 264 V a.c.
Operation method
Z
Zero-cross switching
▍ Specifications
Model
Operating load voltage
Peak voltage (non-repetition)
Rated load current
Frequency
Surge current
(8.3 ms non-repetition )
Leakage current
Output ON voltage drop
Operating voltage range
Impedance
Operating voltage
Reset voltage
Response speed
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Storage temperature
Ambient temperature
Ambient humidity
Applied standard
Load Category
IP Degree
Pollution degree
Weight (g)
Approx. 670 ( box included )
▍ Dimensions
■ 25 A
5.5
5.5
5.6
5.6
4.5
4.5
45.1
45.1
54.9
54.9
100.0
100.0
90.0
90.0
109.0
109.0
HANYOUNGNUX CO.,LTD
28, Gilpa-ro 71beon-gil,
Michuhol-gu, Incheon, Korea
TEL : +82-32-876-4697
http://www.hanyoungnux.com
+C1
INPUT
-C2
POWER
+B1
NC
-B2
NC
AL 80 ℃ (B)
SOLID STATE RELAY
BI AL (A)
SSR-2B252Z
LOAD : 90 - 264 VAC 25 A
INPUT : 4 - 32 VDC 12 mA
AL COM
MADE IN KOREA
CAUTION
• Please make sure that the product specifications are the
same as you ordered.
• Please use the product in places where corrosive gases
(especially harmful gases, ammonia, etc.) and flammable
gases are not generated.
• Please use the product in places without liquids, oils,
chemicals, steam, dust, salt, iron, etc. (pollution degree 1 or 2).
• Please avoid places where large inductive interference,
static electricity,magnetic noise are generated.
• Please avoid places with heat accumulation caused by
direct sunlight, radiant heat, etc.
• When water enters, short circuit or fire may occur, so
please inspect the product carefully.
• Do not connect anything to the unused terminals.
• For DC types, please wire correctly, after checking the polarity
of the terminals.
• When disposing of the product, treat it as industrial waste.
• Pay attention to the edge of the heat sink, which may be sharp.
• The temperature of the main body and the heat sink may
+C1
become extremely high when electric power is applied,
INPUT
which may cause burns.
-C2
POWER
• In case of product malfunction, remove only the main body.
+B1
• Because the SSR heats up when power is on, the lower the
NC
-B2
heat sink and ambient temperatures, the longer the life.
NC
AL 80 ℃ (B)
SOLID STATE RELAY
BI AL (A)
SSR-2B252Z
LOAD : 90 - 264 VAC 25 A
INPUT : 4 - 32 VDC 12 mA
AL COM
MADE IN KOREA
Content
SSR-2C252Z
SSR-2C402Z
90 - 264 V a.c.
600 V
25 A
50/60 Hz (dual usage)
260 A
Max. 10 mA
Max. 1.8 V (RMS)
4 - 32 V d.c.
Max. 4 ㏀
Min. 3 V d.c.
Max. 1.5 V d.c.
Max. 1/2 Cycle + 1 ms
500 V d.c. 100 ㏁ (input/output and among cases )
2,500 V a.c. ( 60 ㎐ for one minute )
10 -55 Hz, double amplitude: 1.5 mm, each X· Y· Z axis for 2 hours
1,000
, each X· Y· Z axis for 3 times
-30 ~ 90 ℃
-20 ~ 80 ℃ (without condensation)
45 ~ 85 % R.H.
IEC 62314
LC A
IP20
2 Rating
Approx. 900 ( box included )
■ 40 A
100.0
100.0
54.9
54.9
45.1
90.0
90.0
109.0
109.0
▍ Part names
INPUT
NC
MC1102KE210701
AL 60 ℃
NC
NC
AL 80 ℃
SOLID STATE RELAY
SSR-2C252Z
LOAD : 90 - 264 VAC 25 A
INPUT : 4 - 32 VDC 12 mA
MADE IN KOREA
▍ Connection example
※ This product is not equipped with an internal fuse.
It is recommended to use a fast fuse separately outside, as shown in the picture.
Load voltage
+C1
INPUT
-C2
NC
AL 60 ℃
NC
(B)
NC
AL 80 ℃
(B)
SOLID STATE RELAY
SSR-2C252Z
LOAD : 90 - 264 VAC 25 A
INPUT : 4 - 32 VDC 12 mA
NC
MADE IN KOREA
LOAD
▍ Load / Input current characteristics
■ Load Current Characteristics
50
SSR-2C40
40
30
SSR-2C25
20
10
40 A
-30 -20
420 A
Ambient temperature (℃)
■ Input Current Characteristics
400
350
300
400
350
250
300
200
250
SSR-2C25
150
200
100
SSR-2C25
150
50
100
0
50
1
0
1
10
▍ Installation interval
• As shown in the figure, set the installation interval to a distance
greater than the corresponding part size.
• Install the wiring duct at less than half the height of the heat
sink, so that it does not obstruct the flow of air.
• Since the SSR is satisfied under the ambient temperature of 25 ° C
or less, always use it in ambient temperatures lower than the
standard temperature.
[Unit : mm]
• When using 40A maximum load, use 10SQ wiring and use
clamping unit or lug when tightening.
45.1
4.5
4.5
5.5
5.5
Air in
● Part names
No.
Content
Load power input terminal
Temperature control signal
(4 - 32 V d.c.)
+C1
Alarm 1 (at a heat sink
-C2
temperature of 60 ℃)
"B contact" internal
bimetallic contact
(B)
Alarm 2 (at a heat sink
temperature of 80 ℃)
"B contact" internal
(B)
bimetallic contact
NC (not used)
NC
LOAD terminal
Status indicator LED
Voltage output of temperature
controller, PLC, etc.
PLC
- All insulation circuit configuration for each
terminal function (temperature control part, alarm part)
50
SSR-2C40
40
30
SSR-2C25
20
10
-30 -20
0
20
40
60
80
100
0
20
40
60
80
100
SSR-2C40
SSR-2C40
10
100
Frequency (60 Hz)
100
1000
▍ Installation method
• Be sure to install the SSR vertically.
• Inevitably, if installed horizontally, the performance of the
product will drop below 50 %.
Air out (FAN)
Wiring duct
• When installing the DIN rail, install it firmly because it is heavy.
Min.
10 mm
• Since the load output terminal width is 13 mm and the input
terminal width is 7 mm, tightly tighten using a terminal that is less
than that. (Load side bolt: M5, control terminal: M3)
+C1
+C1
INPUT
INPUT
-C2
-C2
POWER
POWER
+B1
+B1
NC
NC
-B2
-B2
NC
NC
AL 80 ℃ (B)
AL 80 ℃ (B)
SOLID STATE RELAY
SOLID STATE RELAY
BI AL (A)
BI AL (A)
SSR-2B252Z
SSR-2B252Z
LOAD : 90 - 264 VAC 25 A
LOAD : 90 - 264 VAC 25 A
INPUT : 4 - 32 VDC 12 mA
INPUT : 4 - 32 VDC 12 mA
AL COM
AL COM
MADE IN KOREA
MADE IN KOREA
+C1
+C1
INPUT
INPUT
-C2
-C2
POWER
POWER
+B1
+B1
NC
NC
-B2
-B2
NC
NC
AL 80 ℃ (B)
AL 80 ℃ (B)
SOLID STATE RELAY
SOLID STATE RELAY
BI AL (A)
BI AL (A)
SSR-2B252Z
SSR-2B252Z
LOAD : 90 - 264 VAC 25 A
LOAD : 90 - 264 VAC 25 A
INPUT : 4 - 32 VDC 12 mA
AL COM
INPUT : 4 - 32 VDC 12 mA
AL COM
MADE IN KOREA
MADE IN KOREA
Wiring duct
● Status indicator LED description
Name
LED Color
Content
Lights up when temperature
INPUT
Green
control voltage is applied
● Alarm output
Status
Alarm output
Max.
Normal
AL60°C, AL80 °C
60℃
operation
contact close
AL60° C
Min. 60℃
Alarm output
contact open
AL80 °C
Min. 80℃
Alarm output
contact open
• If the heat sink temperature is lower than the set
temperature the alarm is automatically released.
1000
Horizontal
Vertical
13 mm
7 mm
+C1
L1
Load terminal
Input signal terminal

Advertisement

loading

This manual is also suitable for:

Ssr-2c252zSsr-2c402z