Unpacking and Inspection The Model 261v2 Ion Nozzle has been carefully packed at the factory in a container designed to protect it from accidental damage. Nevertheless, we recommend careful examination of the carton and contents for any damage. If damage is evident, do not destroy the carton or packing material and immediately notify the carrier of a possible damage claim.
The Model 261v2 should be connected to the 233v3, 977CM or 977v3 Pulsed DC Controller. Connect each of the male plugs on the cable of the Model 261v2 to a high voltage socket on the Pulsed DC Controller. In the case of a multiple nozzle installations, use the appropriate pair of high voltage splitters.
Page 8
Compressed Air Connect your air supply directly to the Model 261v2 using 6mm push fit hose. A local compressed air shut-off valve should be installed (not supplied). For most applications, the compressed air supply should be regulated to 30 psi (2 bar). Maximum operating pressure is 100psi (7 bar).
Technical Specification Model 261 Ion Nozzle Body PTFE Length 74 mm Diameter 32 mm Weight 0.06 kg ( Without bracket) Max Air Pressure rating 100 Psi( 7 bar), Typical Pressure 20 to 40Psi (1.5 to 3 Bar) Noise level 68 dBA ( 20 Psi at 1m)(1.5 bar) Emitter Pins machined titanium (7mm) Decay time...
Maintenance Cleaning your Meech Ioniser Ionisers require periodic cleaning. During normal operation, dirt will build-up on the emitter pins and upon the body of the ioniser. This will cause a reduction in performance. Ionising nozzles may need their outlet cap to be removed to allow access to the pins.
Page 11
If the pins are worn and require replacement, the pins should be removed using a pair of round nose pliers and replacements fitted. Replacement pins are available from Meech, item code A-200-EMITP-10/1.0. The exterior of the Ion Nozzle should be kept clean by wiping with a damp cloth.
Fault Finding Tests must be completed by a qualified electrical engineer. If in doubt contact Meech head office or your local distributor. CAUTION: Whilst no danger to personnel exists, it is essential than any high voltage ionising equipment makes no contact with water or water based fluids.
Page 13
If you find this to be the case, then (1) if the plugs are too tight, you should lightly pinch together the two halves of the brass end of the plug with a pair of pliers, or (2) if the plugs are too loose, you should gently open out the slot in the brass end with the blade of a screw-driver or knife.
Repairs and Warranty Your Ion Nozzle is warranted by Meech Static Eliminators Ltd to the original purchaser against defects in material and workmanship for one year after purchase. Should any malfunction occur, please return the Ion Nozzle directly to Meech or to your distributor.
CE Approval An EC Declaration of Conformity for this product exists in respect of the Low Voltage Directive:72/23/EEC (“LVD”) & Electromagnetic Compatibility Directive: 89/336/EEC (“EMCD”) Health and Safety Emission of Ozone: Considerably below international standard of 0.1ppm.
Page 16
Meech International Meech Static Eliminators USA Inc Meech Elektrostatik SA Meech CE 2 Network Point 2915 Newpark Drive Kaiserbaracke 166 Gábor László utca 2 Range Road, Witney Norton, OH 44203 B-4780 St.Vith Budapest 1041 Belgium Hungary OX29 0YN, UK Tel: +44 (0)1993 706700 Tel: +1 330 564 2000 / 1 800 232 4210 Tel.: +49 (0)6555 3733 399...