BE Power Equipment HK070-R User's Manual & Operating Instructions

BE Power Equipment HK070-R User's Manual & Operating Instructions

Oil fired forced convection air heater

Advertisement

Quick Links

CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
DANGER
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
DANGER
WITHOUT ADEQUATE VENTILATION. TO BE USED IN WELL VENTILATED
COMMERCIAL / INDUSTRIAL OCCUPANCIES. This is an unvented portable heater that uses
air (Oxygen) from within the area in which it is used. Failure to provide adequate combustion and
ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to
"Ventilation" on Page 7.
This appliance shall be installed in accordance with the rules in force,
WARNING
and used only in sufficiently ventilated space. Consult instructions before
installation and use of this appliance.
HK070-R / HK125-RW
OIL FIRED FORCED CONVECTION AIR HEATER
HK070-R
ORIGINAL INSTRUCTIONS
© 2020, BAR Group Pty Ltd
15 Hudson Place
Mulgrave NSW 2756, Sydney
User's Manual &
Operating Instructions
HK125-RW
Head Office
BPRI-400

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HK070-R and is the answer not in the manual?

Questions and answers

Summary of Contents for BE Power Equipment HK070-R

  • Page 1 User’s Manual & Operating Instructions HK070-R / HK125-RW OIL FIRED FORCED CONVECTION AIR HEATER HK070-R HK125-RW ORIGINAL INSTRUCTIONS CONSUMER: READ AND SAVE THESE INSTRUCTIONS GENERAL HAZARD WARNING: DANGER READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided with this heater.
  • Page 2: Table Of Contents

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Table Of Contents Safety Information..........1-2 Maintenance...........9-12 Features and Specifications.........3 Troubleshooting Guide........13 HK070-R Assembly..........4 Wiring Diagram..........14 HK125-RW Assembly........5-6 Exploded View..........15, 17 Ventilation............7 Parts List..........15-16, 18 Operation............7-8 Safety Information FIRE, BURN, INHALATION AND EXPLOSION HAZARD.
  • Page 3: Safety Information

    Keep all combustible materials away from this heater. serviced and check for proper ventilation. Some people are more affected by carbon monoxide Minimum Clearance From Combustibles than others. These include: pregnant women, HK070-R HK125-RW those with heart or lung problems, anemia or those 1.2 m 1.2 m under the influence of alcohol or at high altitudes.
  • Page 4 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Specifications Model # HK070-R HK125-RW Rating: kW/Hr 20.5 Fuel Consumption: L/Hr Fuel Tank Capacity: L 15.1 Max Operating Hours Volts: AC/Hz 240VAC / 50Hz 240VAC / 50Hz...
  • Page 5 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions HK070-R Note: Save the box and packaging materials - Remove the heater and all packaging materials from the shipping carton. for future storage. What’s In The Box...
  • Page 6 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions Remove the heater and all packaging Tools Needed: materials from the shipping carton. - Phillips Head Screw Driver - 8 mm open end wrench Tip: Be sure to remove the axle from the Tip: Use a power screwdriver and side of the Styrofoam packaging.
  • Page 7 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions HK125-RW Assembly 4. Attach Radiant Visors to the top and bottom 1. Slide axle through Wheel Frame and attach rear of the Radiant Cone Assembly using extra wheels, washers and nuts.
  • Page 8: Ventilation

    FUELING, AND NEVER OVERFILL THE TANK. DO NOT USE GASOLINE OR WARNING CRANKCASE DRAININGS. Minimum Ventilation Opening Needed HK070-R HK125-RW - NEVER use fuel such as, benzene, alcohol, white 1950 cm 3484 cm gas, camp stove fuel, paint thinners, or other oil compounds in this heater.
  • Page 9 Combustion will stop and the Cooling Cycle will begin. 2. Replace fuel cap and tighten firmly. - HK070-R: approx. 7 mins 3. Connect the heater to a three prong - HK125-RW: approx 3 mins (grounded) power source. You must use a...
  • Page 10: Maintenance

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance - HK070-R Long Term Storage: We suggest following a maintenance schedule as follows: 1. Unscrew the fuel cap. 2. Using an approved siphon (Figure 11.1), TIP: Follow the long term storage remove the kerosene or diesel.
  • Page 11 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance - HK070-R Service (Continued): FILTERS: NOZZLES: The fuel filter and oil filter should be cleaned at Nozzles should be cleaned or replaced at least least twice per heating season by rinsing it in once per heating season.
  • Page 12 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance - HK125-RW Long Term Storage: SPARK PLUG: Clean and re-gap every 600 hours of operation, 1. Unscrew the drain bolt and drain all fuel. or replace as needed After removing the Spark (See Figure 17) Plug, clean the terminals with a wire brush.
  • Page 13 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance - HK125-RW Service (Continued): PHOTOCELL: The photocell should be cleaned at least once per heating season or more depending on conditions. Use a cotton swab and water or alcohol to clean the lens of the photocell.
  • Page 14: Troubleshooting Guide

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Troubleshooting Guide Problem Possible Cause Solution 1. Dirty Fuel Filter. 1. Clean/replace Fuel Filter. 2. Nozzle Dirty. 2. Clean/replace Nozzle 3. Photocell Dirty. 3. Clean/replace Photocell . Heater fires, but shuts down after 4.
  • Page 15 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Wiring Diagrams HK070-R Figure 23 HK125-RW AC240V/50Hz AC230V/50Hz 250V/3.15A Figure 24 Oil Fired Radiant Heater User’s Manual © 2020, BE Pressure Australia...
  • Page 16: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View HK070-R PARTS LIST Part Previous Current Fuel Tank Assembly 75-011-0350 01.01.75.007010691 Fuel Filter 75-023-0285 01.02.75.00702059 Fuel Pipe Assembly 75-023-0345 75-024-0725 Fuel Hose 75-024-0700 75-024-0700 Fuel Gauge 75-022-0210 01.04.75.007010071...
  • Page 17: Parts List

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE PARTS LIST Part Previous Current Motor 75-045-0270 01.04.75.607020260 Plastic Fan Blade 75-047-0200 01.02.75.007010054 Outer Shell 75-011-1110 01.01.75.007020694 Handle 75-001-0060 01.02.75.007010055 Burner Body Supporter 75-011-1100 01.01.75.007010346 Temperature Limit Control 75-040-0110 01.04.75.007020685 Chamber Insulator...
  • Page 18 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View - HK125-RW ALWAYS contact the manufacturer of this heater before replacing any parts WARNING other than those specified or recommended in the servicing instructions. Oil Fired Radiant Heater User’s Manual ©...
  • Page 19 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Parts List: HK125-RW Part Previous Current Fuel Tank Assembly 72-001-0200 01.01.72.012510632 Fuel Gauge Assembly 72-022-0130 01.04.72.012510105 Fuel Tank Cap Assembly 72-035-0615 70-006-0140 Wheel 72-041-1400 01.03.90.003610031 Axle 72-041-0200 01.01.72.012510253 Wheel Frame 72-042-0120...
  • Page 20 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Locating Your Serial Number: Your serial number can be found on a blue label on the left side cover. For Example: S150100001, where the year of manufacture is represented by the 2 digits immediately following the first letter. Model #:________________________________ Serial #:________________________________ Serial Number Label...

This manual is also suitable for: