Arrangement of adjusting positions
Cassette deck mechanism
PB Head
(Deck-A)
Head azimuth screw
Head azimuth screw
(Forward side)
Head azimuth screw
(Reverse side)
Tape recorder section
Measurement
Items
conditions
Cassette Head
Test tape
Azimuth Alignments
: VT703 (10kHz)
Measurement output
terminal
: Left and Right
speaker output
(6-ohm loaded)
or
Headphone Output
(32-ohm loaded)
Recording Bias
Test tape
Frequency Alignment
: TYPE
AC-514
Measurement output
terminal
: Erase head terminal
(CN308 8-Pin)
Tuner section
Measurement
Items
conditions
AM Tracking
Input signal
Alignments
: 530kHz (529kHz)
600kHz (603kHz)
Adjustment point
: Antenna coil (L2)
AM IFT Alignments
Input signal
: 530kHz (529kHz)
Adjustment point
: IFT (T1)
Note: The adjustment of CD section is not required.
All manuals and user guides at all-guides.com
(Front side)
REC/PB Head
(Deck-B)
(Forward side)
Head azimuth screw
(Reverse side)
Measurement method
1. Playback the test tape VT703 (10KHz) or equivalent.
2. Adjust the head azimuth screw to obtain maximum
output and both output of L / R is in 3dB.
3. Put on the screw lock paint after alignments.
1. Insert the recording tape in deck-B.
2. Starting the recording.
3. Adjust the oscillation frequency to 80KHz+/-3KHz by
core of Oscillation coil of L301.
Measurement method
1. Set the Signal Generator signal to 530KHz (529KHz)
the feed to Loop Antenna.
2. Receiving the signal and the adjust the OSC coil (L2)
obtain the V.T is 1.40V +/-0.05V.
3. Change the receiving frequency to 600KHz (603KHz).
4. Adjust the Antenna coil ( L2 ) obtain maximum
sensitivity. (Adjust the SSG output to out of AGC range.)
1. Set the receiving frequency to 530KHz (529KHz )
2. Feed the 450KHz signal to AM antenna input.
3.Adjust the IFT Block T1 obtain to maximum output.
(Adjust the SSG output to out of AGC range.)
Main P.C.B.
TUNER P.C.B.
T1
T1
L2
L2
Standard
values
Maximum output
80kHz+/-3kHz
Standard
values
V . T
: 1.40V+/-0.05V
Maximum
sensitivity
Maximum output
CN308
CN308
L301
L301
8-Pin
8-Pin
Adjusting
positions
Adjust the head
azimuth screw
only when the
head has been
changed.
Use the High-
Impedance Probe
for Frequency
counter input.
Adjusting
positions
Adjust the OSC
coil only when the
AM coil block has
been changed.
Adjust the IFT
only when the IFT
block has been
changed.