Page 1
New EZ Indicator Technology shows users when plate and fastener are ready for installation IMPORTANT! Save this manual and read it in full 153 BOWLES ROAD, AGAWAM, MA 01001 USA before use. 800 . 633 . 3800 413 . 789 . 0252 RHINOBOND.COM...
A B OU T T H I S M AN U AL The AccuTrac EZ tool is presented throughout this manual as the example for processes and instructions. Since the AccuTrac EZ and RhinoTrac EZ tools are similar, the methods presented apply to both tools, except Safety Instructions where noted.
IM PO RTANT S AF E T Y IN S T R U C T I O NS Read and follow all instructions before using the AccuTrac EZ or RhinoTrac EZ Tools. Failure to follow all instructions could result in property damage, electric shock, death or serious personal injury.
Page 4
CAUTION • In addition to the safety instructions in this manual, OMG Roofing Products recommends that all roof top workers follow the safety guidelines outlined in the OSHA booklet called “Protecting Roofing Workers”...
PLEASE NOTE: This manual deals only with the use and operation of the AccuTrac EZ and RhinoTrac EZ tool. For specific information about the use, operation, and limitations of the screw-gun component of the tool, refer to the separate Owner’s Manual provided by the screw gun manufacturer, which has been included with the tool.
T H E ACCUTRAC E Z S Y S T E M Easy-to-use depth adjustment ring sets the precise depth for each Newly-designed “can’t miss” wide fastener/plate to avoid over- and mouth feeder tube that can help under-driving for a quality increase fastener loading speed! installation.
GENERAL 1. Use only with approved plates and fasteners manufactured by OMG Roofing Products. See page 5 for details. 2. At the beginning of each day, wipe down the tubes and the bottom of the ejector plate. Lubricate the linkage and the plate Plate Shuttler, if needed, then unlatch the tool.
2. Shuttle links are pinch points. Use caution when disconnecting them to avoid injury. 3. Contact 413.789.0252 to locate the nearest authorized OMG Roofing Products AccuTrac EZ Distributor and/or service center. SC REW GUN R E MO VA L A N D R E P LA C E M E N T 1.
PLATE SHUTTLE R IN S E R T OR DI SC S NOTICE This step does not apply to RhinoTrac EZ. 1. If the Plate Shuttler is worn and needs to be replaced, the Plate Shuttler assembly must first be removed from the tool. 2.
Plate Shuttler insert disc(s) is/are missing. Replace missing insert. Use only OMG Roofing Products AccuTrac plates with Incorrect plates are being used. AccuTrac EZ tool, or RhinoBond Plates with RhinoTrac EZ tool. Plate Shuttler insert disc undercuts are dirty/clogged. Clean out undercuts.
Page 11
If you have followed the recommendations above, but the problems persist, please call the OMG Roofing Products Technical Services Department at 1.413.789.0252. AccuTrac / RhinoTrac Owner’s Manual Page 11...
Need help?
Do you have a question about the AccuTrac EZ and is the answer not in the manual?