NieRuf EV01 Operating Instructions Manual

NieRuf EV01 Operating Instructions Manual

Solenoid valves

Advertisement

Quick Links

Operating instructions
Solenoid valve, series
Type EV01, MV01
Type MV02
Type EV03, MV03
Type EV04, MV04
Type EV05, MV05
Type EV06, MV06
Type EV07, MV07
Type EV08, MV08
Type EV09, MV09
Type FV01

Advertisement

Table of Contents
loading

Summary of Contents for NieRuf EV01

  • Page 1 Operating instructions Solenoid valve, series Type EV01, MV01 Type MV02 Type EV03, MV03 Type EV04, MV04 Type EV05, MV05 Type EV06, MV06 Type EV07, MV07 Type EV08, MV08 Type EV09, MV09 Type FV01...
  • Page 2 Imprint Imprint Manufacturer NieRuf GmbH Zeppelinstr. 11 74354 Besigheim Germany Phone: +49 (0) 7143 96669 00 Fax: +49 (0) 7143 96669 01 E-mail: info@nieruf.de Website: www.nieruf.de Published by NieRuf GmbH Printed by NieRuf GmbH Translation These operating instructions in English are a translation of the original German operating instructions.
  • Page 3: Table Of Contents

    3.1 Type label ............................ 9 3.2 Description ..........................9 3.3 Design and dimensions ......................10 3.3.1 Type EV01 and MV01 ......................10 3.3.2 Type MV02 ......................... 10 3.3.3 Type EV03 and MV03 ......................10 3.3.4 Type EV04 and MV04 ......................11 3.3.5 Type EV05 and MV05 ......................
  • Page 4 9.1 Technical data ........................... 22 9.2 Circuit diagrams ......................... 22 9.2.1 Circuit diagrams Type EV01 /-03 and MV01 /-02 /-03 ............22 9.2.2 Circuit diagrams Type EV04 /-05 /-07, MV04 /-05 /-07 and FV01 ........22 9.2.3 Circuit diagrams Type EV06 and MV06 ................22 9.2.4 Circuit diagrams Type EV08 /-09 and MV08 /-09 ...............
  • Page 5: About These Instructions

    1.2 Other applicable documents Data sheet § If not available, the data sheet must be requested from the manufacturer. 1.3 Guarantee NieRuf GmbH accepts no liability if operators or third parties: Disregard this document § Do not use the product properly §...
  • Page 6: Warning Notices And Symbols

    1 About these instructions 1.4 Warning notices and symbols DANGER High risk Denotes an imminent danger that will result in serious injuries or death if not avoided. WARNING Medium risk Denotes a possibly dangerous situation that may result in serious injuries or death if not avoided.
  • Page 7: General Safety Instructions

    2 General safety instructions 2 General safety instructions NOTE Liability The manufacturer accepts no liability for damage resulting from the failure to observe the complete documentation. 2.1 Intended use The valve must be used exclusively for shutting off pipelines carrying suitable media §...
  • Page 8: Duties Of The Personnel

    2 General safety instructions Personnel qualifications Make sure that personnel tasked with carrying out activities using the valve have read and § understood these instructions and all other applicable documents before starting work, especially safety, maintenance and repair information. Manage the responsibilities, competencies and supervision of personnel. §...
  • Page 9: Design And Function

    § Connector complies with DIN EN 175301-803 form A. § o Types EV01 / -09 and MV01 / -09 with DIN EN 175301-803 form B Flow direction as per direction arrow on the valve body. § Valves are not suitable for back pressure.
  • Page 10: Design And Dimensions

    3 Design and function 3.3 Design and dimensions 3.3.1 Type EV01 and MV01 Designation Material Connector Plastic Coil housing Plastic or metal Valve body Brass or stainless steel Seal material NBR, EPDM or FKM 3.3.2 Type MV02 Designation Material Connector...
  • Page 11: Type Ev04 And Mv04

    3 Design and function 3.3.4 Type EV04 and MV04 Designation Material Connector Plastic Coil housing Plastic or metal Cover Brass or stainless steel Valve body Brass or stainless steel Seal material NBR, EPDM or FKM 3.3.5 Type EV05 and MV05 Designation Material Connector...
  • Page 12: Type Ev07 And Mv07

    3 Design and function 3.3.7 Type EV07 and MV07 Designation Material Connector Plastic Coil housing Plastic or metal Cover Brass or stainless steel Valve body Brass or stainless steel Seal material NBR, EPDM or FKM 3.3.8 Type FV01 Designation Material Connector Plastic Coil housing...
  • Page 13: Transport, Storage And Disposal

    4 Transport, storage and disposal 4 Transport, storage and disposal 4.1 Unpacking On receipt of the armature, unpack it, check it for signs of transport damage and ensure that § it is complete. Transport damage or missing components must be reported to the manufacturer §...
  • Page 14: Installation And Connection

    5 Installation and connection 5 Installation and connection 5.1 Preparing the installation 5.1.1 Checking conditions of use Make sure that the valve design is suitable for the intended use: § Materials used Medium Ensures the necessary conditions of use § The resistance of the materials used for the body and seals against the medium Media temperature Operating pressure...
  • Page 15: Fitting The Valve To A Pipeline

    5 Installation and connection 5.3 Fitting the valve to a pipeline WARNING De-pressurised fitting. Only fit the valve to de-pressurised pipelines. WARNING Danger of poisoning and environmental damage from the medium Leakage due to incorrect installation. Installation work on the pipelines must only be carried out by skilled workers who are trained for the respective pipeline system.
  • Page 16: Electrical Connection

    5 Installation and connection 5.4 Electrical connection DANGER Danger to life due to electric shock Only allow an electrician to work on the electrical system. Switch off the power supply to the system and secure it to prevent it from being accidentally switched on again. Connect protective conductors.
  • Page 17: Operation

    6 Operation 6 Operation 6.1 Commissioning The valve must be correctly assembled and connected. WARNING Danger of poisoning and environmental damage from the medium Leakage due to leaks caused by impermissible pipeline forces. Make sure that no tensile or compressive forces and no bending moments act on the armature.
  • Page 18: Maintenance And Repairs

    7 Maintenance and repairs 7 Maintenance and repairs WARNING Risk of injury and poisoning by media During all work on the valve, wear personal protective equipment. 7.1 Maintenance Visual and functional inspection (quarterly): § No change in normal operating states Leak-tightness No unusual operating noises and vibrations If necessary, clean valve with a damp cloth.
  • Page 19: Removing Valves

    7 Maintenance and repairs 7.2.1 Removing valves Make sure that: § System is drained System is flushed System is de-pressurised System is cooled System is secured against reactivation Remove valve from the pipeline. § If necessary, decontaminate valve. § Empty spaces in the valve may still contain medium. 7.2.2 Replacing solenoid coils 1.
  • Page 20: Spare Parts

    The valve may be damaged if unsuitable packaging is used. Always use the original packaging and handle the product with care. NieRuf GmbH accepts no responsibility for damage caused by the use of unsuitable packaging! OPERATING INSTRUCTIONS FOR METAL SOLENOID-VALVES...
  • Page 21: Fault Elimination

    8 Fault elimination 8 Fault elimination WARNING Risk of injury and poisoning by media During all work on the valve, wear personal protective equipment. Any medium leaks must be safely contained and disposed of in an environmentally-safe manner. Faults that are not mentioned in the table below or which cannot be attributed to the causes specified should be discussed with the manufacturer.
  • Page 22: Appendix

    Please refer to the data sheet for technical data such as the operating pressure or the operating temperature. If the data sheet is not available, request it from the manufacturer. 9.2 Circuit diagrams 9.2.1 Circuit diagrams Type EV01 /-03 and MV01 /-02 /-03 Switching function: NC (normally closed) 9.2.2 Circuit diagrams Type EV04 /-05 /-07, MV04 /-05 /-07 and FV01...
  • Page 23: Declaration Of Conformity

    9 Appendix 9.3 Declaration of conformity OPERATING INSTRUCTIONS FOR METAL SOLENOID-VALVES Index: 0 23/23...

Table of Contents