Anchor Bolts
Pole
The components contained in these modules shall only be replaced by the manufacturer
or his service agent or a similar qualified person.
Always switch off the power prior to installa�on, maintenance or repair ac�vi�es.
A
GENERAL DIMENSIONS
HEIGHT
mm
ft
6840
22.4
6650
21.8
6460
21.2
20.6
6270
19.9
6080
19.3
5890
18.7
5700
18.1
5510
17.5
5320
16.8
5130
16.2
4940
15.6
4750
15
4560
4370
14.3
4180
13.7
3990
13.1
3800
12.5
3610
11.8
3420
11.2
3230
10.6
3040
10
2850
9.4
2660
8.7
2470
8.1
2280
7.5
00-63-030 | DOC-0016143 Rev C | 11-2019
Christmas
socket
Power
sockets
8x
Nuts
Washers
WEIGHT
lb
kg
276
125
267
121
260
118
254
115
245
111
238
108
229
104
220
100
214
97
205
93
196
89
190
86
181
82
174
79
165
75
159
72
150
68
143
65
134
61
128
58
119
54
110
50
104
47
95
43
4X Anchor Bolt
88
40
8x M18 Nuts
8x 18mm Washers
Key Lock
System
SHUFFLE POLE
Plate Guide
Pole Flange
M18
400mm
15.8in
www.schreder.com
Installation Instructions
Tools not supplied
4
6
Depending on the version
Tool is delivered with the pole.
KEY
193mm / 7.6in
400mm | 15.75in
300mm | 11.8in
52mm
2.04in
FLANGE PLATE
27
1 x M8 SCR Tri
Head DIN 22424 C
170mm
6.69in
27mm
1.06in
1/14

Advertisement

loading
Need help?

Need help?

Do you have a question about the SHUFFLE POLE and is the answer not in the manual?

Questions and answers

Summary of Contents for Schreder SHUFFLE POLE

  • Page 1 Key Lock Christmas System socket SHUFFLE POLE Power sockets Installation Instructions Nuts Plate Guide Anchor Bolts Washers Pole Pole Flange The components contained in these modules shall only be replaced by the manufacturer or his service agent or a similar qualified person.
  • Page 2 - Door without cut out 7.6in - Intercom 145mm 5.7in 706mm 27.8in - EV charger 145mm 5.7in 446mm 17.6in 1050mm 41.3in 400mm 15.7in - Door with cut out mains door (Power Sockets) multipurpose door 2/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
  • Page 3 193mm C5 - SIDE CABINET 7.6in 65mm 2.6in 80mm 3.2in 150mm 145mm 5.9in 5.7in 666mm mains door 26.2in 145mm 5.7in 1250mm access door 49.2in 450mm 17.7in 3/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
  • Page 4 TYPES OF DOORS DOOR LOCKING SYSTEM Inner Hexagonal Triangular Key Lock Head Screw Head Screw MAINS BEYOND LIGHT MULTIPURPOSE CHRISTMAS DOOR DOOR DOOR DOOR KEY LOCKING SYSTEM Unlocked - Open Locked -Closed 4/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
  • Page 5 It should have enough space for M18 nuts, washers and tool for tightening. The anchor bolts are delivered along with the pole (flange plate version). Fill the moulding with concrete C16/20 (B20). After concrete curing, remove jig. 5/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
  • Page 6 flange plate. Fully tighten the nuts following the recommended torque values. Check the correct vertical alignment of the pole. 6/14 00-63-030 | DOC-0016143 Rev C | 11 -2019 www.schreder.com...
  • Page 7: Recessed Mounting

    800/1000mm 9.8in 19.7in 31.5/39.4in Put the column in place guiding the underground electrical cables through the pipe until they reach the base compartment and the column is at the right depth. 7/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
  • Page 8 Pole should be oriented in a way that performing Perform nearby soil compaction, preferably any kind of maintenace is easy and safe. with a mechanical vibration compacter. Check the correct vertical alignment of the pole. 8/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
  • Page 9 6.6 lb.ft 1 x SCR Tri Head DIN 22424 C 9 N.m 6.6 lb.ft +0.7 9 N.m 6.6 lb.ft +0.7 The lock plate has to be tightened to the nut to rotate. 9/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
  • Page 10 C-RAIL MOUNTING Max 2x C-rail for the same door 1 x M8 5 N.m 3.7 lb.ft 1 x M8 5 N.m 3.7 lb.ft 10/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
  • Page 11 Powered by Mains Lighting Box Light Line: max. 1000W Other Line: max. 1200W Powered by Beyond Lighting Mains Box max. 3500W With plug Without plug Door cut out Door cut out Bottom 185.4 11/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
  • Page 12 Connect cable to Socket Box. Socket box should be mounted within the Mains Door. See DOC- 0016042 Boxes and Cabling Installation Instruction. Door cut out 2x M5 with plug 2.5 N.m 1.8 lb.ft +0.7 12/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
  • Page 13 1 x M8 SCR Tri Head DIN 22424 C max 3500W / line Without cable With cable 186 mm 7.3 in 706mm 27.8in 171mm 129 mm 6.7in 5 in 145mm 5.7in 750mm 29.5in 13/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
  • Page 14 Cable cover protective switch (RCBO) Close maintenance flap properly. 1 x SCR Tri Head DIN 22424 C 9 N.m 6.6 lb.ft +0.7 9 N.m 6.6 lb.ft +0.7 Slide up Pass Cables 14/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...