Do you have a question about the SHUFFLE POLE and is the answer not in the manual?
Questions and answers
Summary of Contents for Schreder SHUFFLE POLE
Page 1
Key Lock Christmas System socket SHUFFLE POLE Power sockets Installation Instructions Nuts Plate Guide Anchor Bolts Washers Pole Pole Flange The components contained in these modules shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Page 2
- Door without cut out 7.6in - Intercom 145mm 5.7in 706mm 27.8in - EV charger 145mm 5.7in 446mm 17.6in 1050mm 41.3in 400mm 15.7in - Door with cut out mains door (Power Sockets) multipurpose door 2/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
Page 3
193mm C5 - SIDE CABINET 7.6in 65mm 2.6in 80mm 3.2in 150mm 145mm 5.9in 5.7in 666mm mains door 26.2in 145mm 5.7in 1250mm access door 49.2in 450mm 17.7in 3/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
Page 4
TYPES OF DOORS DOOR LOCKING SYSTEM Inner Hexagonal Triangular Key Lock Head Screw Head Screw MAINS BEYOND LIGHT MULTIPURPOSE CHRISTMAS DOOR DOOR DOOR DOOR KEY LOCKING SYSTEM Unlocked - Open Locked -Closed 4/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
Page 5
It should have enough space for M18 nuts, washers and tool for tightening. The anchor bolts are delivered along with the pole (flange plate version). Fill the moulding with concrete C16/20 (B20). After concrete curing, remove jig. 5/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
Page 6
flange plate. Fully tighten the nuts following the recommended torque values. Check the correct vertical alignment of the pole. 6/14 00-63-030 | DOC-0016143 Rev C | 11 -2019 www.schreder.com...
800/1000mm 9.8in 19.7in 31.5/39.4in Put the column in place guiding the underground electrical cables through the pipe until they reach the base compartment and the column is at the right depth. 7/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
Page 8
Pole should be oriented in a way that performing Perform nearby soil compaction, preferably any kind of maintenace is easy and safe. with a mechanical vibration compacter. Check the correct vertical alignment of the pole. 8/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
Page 9
6.6 lb.ft 1 x SCR Tri Head DIN 22424 C 9 N.m 6.6 lb.ft +0.7 9 N.m 6.6 lb.ft +0.7 The lock plate has to be tightened to the nut to rotate. 9/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
Page 10
C-RAIL MOUNTING Max 2x C-rail for the same door 1 x M8 5 N.m 3.7 lb.ft 1 x M8 5 N.m 3.7 lb.ft 10/14 www.schreder.com 00-63-030 | DOC-0016143 Rev C | 11-2019...
Page 11
Powered by Mains Lighting Box Light Line: max. 1000W Other Line: max. 1200W Powered by Beyond Lighting Mains Box max. 3500W With plug Without plug Door cut out Door cut out Bottom 185.4 11/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
Page 12
Connect cable to Socket Box. Socket box should be mounted within the Mains Door. See DOC- 0016042 Boxes and Cabling Installation Instruction. Door cut out 2x M5 with plug 2.5 N.m 1.8 lb.ft +0.7 12/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
Page 13
1 x M8 SCR Tri Head DIN 22424 C max 3500W / line Without cable With cable 186 mm 7.3 in 706mm 27.8in 171mm 129 mm 6.7in 5 in 145mm 5.7in 750mm 29.5in 13/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
Page 14
Cable cover protective switch (RCBO) Close maintenance flap properly. 1 x SCR Tri Head DIN 22424 C 9 N.m 6.6 lb.ft +0.7 9 N.m 6.6 lb.ft +0.7 Slide up Pass Cables 14/14 00-63-030 | DOC-0016143 Rev C | 11-2019 www.schreder.com...
Need help?