Armagard Standard V2 Setup Manual

Controller board

Advertisement

Controller Board Setup – Standard V2
Setup Manual
READ THIS MANUAL THROUGH BEFORE INSTALLING YOUR UNITS TO ENSURE CORRECT
INSTALLATION AND THAT YOU'RE COVERED UNDER WARRANTY.
1. The following manual details the information
and safety precautions needed for the safe
installation of the Armagard standard
controller board.
2. All power must be switched off until the
enclosure has been fully assembled and is
ready to use.
3. If your enclosure is for outdoor use, don't
attempt installation in bad weather; use
correct lighting for optimum viewing
conditions.
4. Armagard recommends that the enclosure
should always be secured to the floor or wall
before adjusting the controller board.
YOUR WARRANTY AGREEMENT IS VOID
controller board, for example, drilling or penetrating any additional holes into the board.
FOR BEST PRACTICE
procedure.
www.Armagard.com
if you perform any modifications to the
mount the controller board cover using the recommended
5. Because of its watertight seal, to lock an
enclosure you have to push firmly against
the door and then turn the key.
6. All images used in this manual are for
reference and example purposes only.
7. The final controller board you receive will
differ depending on what has been agreed
on the order with your account manager.
8. Software is compatible with Windows XP, 7,
8 & 10.
Toll Free (US):
Page |
1-866-434-0807
Call (UK):
0121-608-7210
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Standard V2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Armagard Standard V2

  • Page 1 Controller Board Setup – Standard V2 Setup Manual READ THIS MANUAL THROUGH BEFORE INSTALLING YOUR UNITS TO ENSURE CORRECT INSTALLATION AND THAT YOU’RE COVERED UNDER WARRANTY. 1. The following manual details the information 5. Because of its watertight seal, to lock an...
  • Page 2 The printed circuit board (PCB) automatically manages the on-off commands for an enclosures air curtains, fans, heaters, and power outlets. Setup Kit To reconfigure the controller board, you’ll need the setup kit which is provided by Armagard as an optional extra. 1. USB setup cable.
  • Page 3 How to Connect to the Board Step 1: Locate your USB setup cable and download the appropriate drivers from Armagard’s support website (files needed are detailed on the previous page). Step 2: To configure the controller board you’ll need a computer (ideally a laptop) close enough for the USB setup cable to reach the controller board.
  • Page 4 Step 10: Set the default BAUD rate for setup as 19200. These can be selected from the pre- set figures shown in figure 3 box 2 above. Now click ‘connect’, highlighted in figure 3 box 3 above. Page | Toll Free (US): 1-866-434-0807 www.Armagard.com Call (UK): 0121-608-7210...
  • Page 5 (Fahrenheit) followed by the return key, such as 40C. Note: The menu will time out after 30 seconds if no commands are received and the system will switch back on. Page | Toll Free (US): 1-866-434-0807 www.Armagard.com Call (UK): 0121-608-7210...
  • Page 6 (figure 1a). Step 2: Secure the relevant wires specific to your region into the ‘Neutral (N), Live (L) and Earthed (E)’ outlets (figure 2a). Figure 2a Page | Toll Free (US): 1-866-434-0807 www.Armagard.com Call (UK): 0121-608-7210...
  • Page 7 Make sure to select the window you’re working with properly. If the terminal program still seems unresponsive, press disconnect at the top of the window and then press reconnect to establish a new link. Page | Toll Free (US): 1-866-434-0807 www.Armagard.com Call (UK): 0121-608-7210...

Table of Contents