Quickstart
DLT-U1100
Qualifications required for mounting of the UPS DLT-U1100
This Quickstart Poster will show you how to perform the mechanical and electrical mounting
of the Uninterruptible Power Supply (UPS) DLT-U1100. It is intended for skilled persons.
WARNING: Electric shock due to contact with live parts / property damage
• Only electronic and mechanical skilled persons are permitted to install the
DLT-U1100. Specialized knowledge of batteries and the applicable safety
regulations is also required.
• Unauthorized persons must be kept away from the UPS which contains
rechargeable Lithium Ion batteries.
• If the DLT-U1100 is incorrectly installed and configured, the DLoG GmbH warranty
for this device will be canceled.
• DLoG GmbH assumes no liability for damages caused directly or indirectly
by the incorrect installation or usage of the DLT-U1100.
• DLT-U1100 operators must be trained.
Current manuals on the internet
The current DLT-U1100 manuals can always be found in our Download Center
on the internet
www.advantech-dlog.com
WARNING: Explosion hazard
• Do not use the DLT-U1100 at locations where flammable gases or vapors are
present.
• Do not use the DLT-U1100 near gas stations, fuel depots, chemical facilities or
locations where blasting work is being performed.
• Do not throw the DLT-U1100 into fire; the batteries may explode.
WARNING: Electrical shock possible from touching live parts / property damage
• Do not commission the DLT-U1100 if there are visible signs of damage to the
device.
• The DLT-U1100 contains Lithium Ion batteries. Replacement of the rechargeable
batteries by the customer is expressly prohibited.
• Do not open or modify the DLT-U1100.
• Do not perform any repairs. Repairs on the DLT-U1100 may be made only by
Service Centers authorized by Advantech-DLoG.
• Do not submerge the DLT-U1100 and cables in water or other liquids because of
the danger of electrical shock.
• Use only original power cables by Advantech-DLoG; they meet special
requirements for low-temperature flexibility, UV resistance, oil resistance, etc.
• Condensation can occur if the DLT-U1100 is moved from a cold environment into
a work room. Therefore, allow for an acclimatization time of approx. 2 hours.
Battery
Bridging time
Maximum output
Nominal output voltage of the UPS
Nominal input voltage of the UPS
Input voltage range
Output voltage range
Charging time
Connector input
Connector output
Mounting by electronic and mechanical skilled persons
(Download menu).
Lithium-ion battery
10 min
40 W
12 VDC
12, 24, 48 VDC
9 to 60 VDC
10 to 14 VDC
2,5 h (fully recharge a completely discharged battery)
Lumberg 0315 04-Pin male
Lumberg 0305 04-Pin female
Intended use
The DLT-U1100 is a battery-operated uninterruptible power supply for the Advantech-DLoG
industrial PCs MTC 6 and XMT 5, each with 12/24 VDC power supply unit.
Any other or additional use is not as intended.
The user/operator of the DLT-U1100 is solely respon-
sible for any resulting damage. This also applies to
unauthorized modifications to the unit.
If the DLT-U1100 is connected, MTC 6 and XMT 5 cannot be started or shut down automati-
cally via vehicle ignition.
The following icons are used in this quick start guide to indicate dangers:
Personal injury
Explosion hazard
NOTICE Risk of physical damage
Important notes
NOTICE: No combination of UPS + automatic start/shut down via ignition
possible
MTC 6 and XMT 5 can be used with automatic startup/shut down capabilities.
This automatic feature controls the startup and shutdown of the industrial PC
via the <POWER> button or the vehicle's ignition.
If the DLT-U1100 is connected, MTC 6 and XMT 5 cannot be started or shut down via
vehicle ignition
Hence it is important to make the following setting before the DLT-U1100 is connected
to MTC 6 and XMT 5:
• Define that the MTC 6 and XMT 5 always start and shut down with the
<POWER> button, not via ignition signal.
• Make the respective adjustments in the configuration tools:
"DLoG Config" for MTC 6, "DLoG NextConfig" for XMT 5
Otherwise, MTC 6 and XMT 5 can not be started, because with a connected UPS
system no ignition signal is available.
WARNING: Vehicle "EMERGENCY Stop Switch" cannot switch off industrial
PCs with UPS
If an MTC 6 or XMT 5 industrial PC with an uninterruptible power supply (UPS) is
installed on a vehicle, the vehicle emergency stop switch will not affect the the
industrial PC.
Technical data
Temperature range, in which the UPS supplies
the industrial PC with power from the battery
Temperature range, in which the batteries
of the UPS are recharged
Storage temperature range
Vibration/shock
IP protection
Weight
Warranty DLT-U1100 device (batteries
excluded)
Warranty batteries
1
2
3
-10 to +50 °C (+14 to +122 °F)
0 to +45 °C (+32 to +113 °F)
-20 to +60 °C (-4 to +140 °F)
Class 5M3 according to DIN EN 60721-3-5
IP65
1.1 kg
As specified in Advantech-DLoG TOB
Six (6) months from delivery