ORDERING INFORMATION DIMENSIONS HANDLING AND TRANSPORTATION OPERATING HAZARDS PRECAUTIONS http://www.dropsa.com Dropsa products can be purchased from Dropsa branches and authorized distributors, visit Via Benedetto Croce, 1 www.dropsa.com/contact or contact us dropsa@sales.com Vimodrone, MILANO (IT) t. +39 02 250791 C2247IE WK 27/15...
Min oil 100 cSt -20 +65 °C Storage temperature N.b. The specifications refer to the temperature of use of +20°C (+68°F) * If a different product is used, please contact Dropsa S.p.A. to ensure it is suitable for use...
Page 3
4.1 Hydraulic system Activation line 1 (fig.1) - with valve in position "a" the pump pushes lubricant to line 1. Line 2 is discharge phase. Fig.1 Exchange line 1->2 (fig.2) - when fluid reaches the adjusting spring pressure calibration "PS1", the pilot conduit opens causing the displacement of the chamber from the position "b"...
DO NOT use lubricants that may irritate the NBR gaskets; if in doubt, contact the Dropsa SpA technical Check that the electrical connection has been carried office, which can provide you with a detailed chart of out correctly;...
Breaking of internal gaskets Replace lubricant : Operations by specialized Dropsa personnel (ship the product to Dropsa headquarters) 9. MAINTENANCE PROCEDURE The product does not necessitate any special tool for operation and maintenance. When working with the pump it is nonetheless recommended that personal health and safety equipment is used as is normal for any operation in an industrial or similar workplace.
12. DIMENSIONS Dimensions in mm [in]. 13. HANDLING AND TRANSPORT Before shipping, the units are carefully packed inside cardboard boxes. When transporting and storing the equipment, pay attention to the direction indicated on the boxes themselves. Upon receipt, check that the package has not been damaged and store the equipment in a dry location. 14.
Page 8
Unsuitable Lubricant. Lubricant characteristics are indicated on the pump and in this user manual. In any case contact a Dropsa Sales and Support engineer (if in any doubts, contact the Technical Department Dropsa SpA). FLUIDS EXPLICITY NOT ALLOWED...
Need help?
Do you have a question about the 0086450 and is the answer not in the manual?