Summary of Contents for Livongo BG1000

  • Page 1 • Livongo Connected Meter (1) • Livongo Blood Glucose Control Solution (2) • LIvongo Lancing Device (1) • Livongo User Guide / Instructions for Use (1) Livongo for • Livongo Lancets (100) • AC Adapter (wall charger) and USB Cable (Set) •...
  • Page 2: Table Of Contents

    Cleaning and Disinfecting the Livongo Meter ........
  • Page 3: The Livongo For Diabetes Program

    Getting Started The Livongo meter comes ready to use right out of the box and is already charged and ready for your first blood sugar check. Note: If you have cellular connectivity, your meter’s date and time will be automatically updated after you do your first check.
  • Page 4: Checking Your Blood Sugar

    (meals page 11 for instructions on how to the screen of your meter and feelings) to your use the lancing device .) during this time.) Livongo account. Livongo for Diabetes User Guide Livongo for Diabetes User Guide...
  • Page 5: Accessing Your Data

    Power On / Power Off / Sleep Mode You can access your data on the Livongo meter by tapping See More on the home screen data • To power on your Livongo meter when it is completely off, press and hold the power button for card.
  • Page 6: Using The Livongo Lancing Device

    Using the Livongo Lancing Device The Livongo lancing device is simple to use. Please follow these instructions: Remove the cap by turning it counterclockwise and then 1. Remove the lancing device cap: pulling it straight off the lancing device. Align the lancet so that it fits into the lancet holder. Push the lancet into the 2.
  • Page 7 Using the Livongo Lancing Device (Cont.) 4. Adjust the depth setting: The lancing device has 11 puncture depth settings, numbered 0 through 5. Smaller numbers are for a shallower puncture. Turn the depth wheel to choose the setting. A shallower puncture may reduce discomfort. It is recommended that you start...
  • Page 8 Important Safety Instructions q Do NOT try to open and change the Livongo meter’s battery. It is built-in and not changeable. q Do NOT use your meter in close proximity to sources of strong electromagnetic radiation. Please take a minute to read through this important safety information. Remember, this is a medical q Other equipment could interfere with the Livongo meter, even if the other equipment complies with device and it needs to be used with caution and care.
  • Page 9: Important Symbols

    The outside temperature is above 113°F, which is too high to give an accurate reading. Too High Keep away from sunlight Keep dry Temperature The outside temperature is below 41°F, which is too low to give an accurate reading. Too Low Direct current Livongo for Diabetes User Guide Livongo for Diabetes User Guide...
  • Page 10 Calibration Member Support. Error Hematocrit Your hematocrit level is below 20% or above 70%. The Livongo meter operates in the Error hematocrit range of 20% to 70%. Very high (above 70%) and very low (below 20%) Internal Meter Please turn off the meter for 30 seconds and turn it back on. If the error persists, contact hematocrit levels can cause false results.
  • Page 11: Cleaning And Disinfecting The Livongo Meter

    Disinfection Wipes Material and Where to Buy Them Disinfection Wipe EPA Registration No. Contact Time The materials suitable for the Livongo meter pre-cleaning and disinfection are listed on the PDI Super Sani-Cloth Germicidal 9480-4 2 minutes next page.
  • Page 12 Your Livongo meter should be cleaned and disinfected once a week. If someone else is helping you test, the meter should be disinfected prior to operation by that person. Your meter has been...
  • Page 13 Appendix If you have any questions about your Livongo meter, please contact Member Support at (800) 945-4355 or email us at membersupport@livongo.com. We are available 24 hours a day, 7 days a week. Livongo for Diabetes User Guide Livongo for Diabetes User Guide...
  • Page 14 • Rated capacity (Battery): 2400mAh, 9.24Wh peak@3.85V • Measuring range: 40–600 mg/dL • Maximum current (USB input, charging): • Acceptable hematocrit range: 20% to 70% 1A continuous • USB charging input: 5V 1A Livongo for Diabetes User Guide Livongo for Diabetes User Guide...
  • Page 15 (1) this the regulatory limits set by the US Federal is no guarantee that interference will not not been found to affect the Livongo meter. device may not cause harmful interference, Communications Commission (FCC) occur in a particular installation. If this...
  • Page 16 Privacy Policy neglect, unauthorized maintenance or As the manufacturer of the Livongo meter, we are committed to securing your personal information Your Livongo connected meter is guaranteed failure to operate meter in accordance responsibly and in compliance with the law. Learn more at: https://my.livongo.com/common/docs/...
  • Page 17 Contents Blood Glucose Monitoring System ......................E-3 Blood Glucose Test Strips ........................E-4–15 Blood Glucose Control Solution ....................... E-15–19 Lancing Device ............................E-20–25 BLOOD GLUCOSE MONITORING SYSTEM Instructions for Use References ................................E-26 Limited Warranty ............................. E-26 Contact Information ............................E-27 Instructions for Use Instructions for Use...
  • Page 18: Blood Glucose Monitoring System

    The Livongo Blood Glucose Monitoring System is for in vitro diagnostic use. diabetes control program and should not be used for the diagnosis of/or screening for diabetes The Livongo Blood Glucose Monitoring System is not intended for the diagnosis of or screening mellitus or for neonatal use.
  • Page 19: Blood Glucose Test Strips

    BLOOD GLUCOSE TEST STRIPS BLOOD GLUCOSE TEST STRIPS • Do not store any part of the system near bleaches or cleaners that contain bleaches. Composition Each test strip has reactive and non-reactive chemicals. These chemicals are: FAD-dependent • Do not move the test strips to a new vial or any other container. Glucose Dehydrogenase <25 IU, Mediator <300 µg, Buffer, and Non-reactive Ingredient.
  • Page 20 BLOOD GLUCOSE TEST STRIPS BLOOD GLUCOSE TEST STRIPS • Do not use test strips after the expiration date that is shown on the vial. Expired test strips may Instructions for Use give an incorrect result. 1. Open the cap of the test strip vial and take out a test strip. Replace the cap to protect the other •...
  • Page 21 Less than 7.8 Checking the System • The Livongo meter should not be used to test critically ill patients and Livongo meter should not be used to test neonates. Be careful with your blood glucose meter. Do a quality control test to make sure that the meter and test strips are working well together.
  • Page 22 12.37 2.50 11.45 ~ 13.44 Performance Characteristics The precision and accuracy of the Livongo meter is calibrated by using a YSI (Model 2300 STAT PLUS) Glucose Analyzer as the reference instrument. It is traceable to the NIST reference standard. E-11...
  • Page 23 The chart on the next page shows the results of a study where 383 typical users used the Livongo meter to test their blood glucose level. For example, in this study, the Livongo meter gave results within 15% of their true blood glucose level 382 out of 383 times.
  • Page 24: Blood Glucose Control Solution

    Control Solution 1 is sufficient for most self-testing needs. If you think your meter or strips may not Livongo control solution contains a known concentration of glucose. It is used to confirm that your be working correctly, you may also want to do a level 2 test.
  • Page 25 Discard the test strip and start over with a new test strip. • Use only Livongo brand control solution with your Livongo meter and test strips. Please contact Member Support at (800) 945-4355 for more information on obtaining a control 5.
  • Page 26: Lancing Device

    BLOOD GLUCOSE CONTROL SOLUTION LANCING DEVICE If the test results are in the respective ranges, this means your Livongo Blood Glucose Monitoring Principle and Intended Use System is working right and you are doing the procedure correctly. The Livongo lancing device is used with compatible...
  • Page 27 LANCING DEVICE LANCING DEVICE 4A–4B. Adjust the puncture depth by rotating the lancing device cover. There The lancing device is for fingertip sampling only. Adjust the depth penetration to reduce are a total of 11 puncture depth settings. To reduce discomfort, use the lowest the discomfort.
  • Page 28 LANCING DEVICE LANCING DEVICE Massage the hand from the wrist up to the fingertip a few times to encourage CARE OF THE LANCING DEVICE blood flow. Cleaning and Disinfection 7A–7B. Hold the lancing device against the side of the finger to be lanced with First use DisCide Ultra Disinfecting Towelettes to clean the entire device surface.
  • Page 29: References

    LANCING DEVICE REFERENCES American Diabetes Association (Standards of Medical Care in Diabetes – 2018. Diabetes Care, • Do not share with anyone including other family members! Do not use on multiple patients! January 2018, vol. 41, Supplement 1, S13-S27). • All parts of the kit are considered biohazardous and can potentially transmit infectious diseases, even after you have performed cleaning and disinfection.
  • Page 30: Contact Information

    Control Solution Manufactured for Livongo Mountain View, CA 94041 Health by: (800) 945-4355 Acon Biotech (Hangzhou) Co., Ltd. www.livongo.com No.210 Zhenzhong Road West Lake District Made in China 2019 © Livongo. All rights reserved. E-27 Instructions for Use Instructions for Use E-28...