Ozone AM5000 Series Installation, Operating, Maintenance

Ozone generator

Advertisement

Quick Links

AM5000
SERIES
Ozone Generator
INSTALLATION, OPERATING & MAINTENANCE
INSTRUCTIONS FOR MODELS
AM5100, AM5101, AM5200
AM5201
Model Specifications:
AM5100 - 1gm/hr output
AM5101 - 1gm/hr output with countdown timer
AM5200 - 2gm/hr output
AM5201 - 2gm/hr output with countdown timer
For settings see appendix A
AM5000 Doc No. 290-062-00 Rev. A June 2005

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AM5000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ozone AM5000 Series

  • Page 1 AM5000 SERIES Ozone Generator INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR MODELS AM5100, AM5101, AM5200 AM5201 Model Specifications: AM5100 - 1gm/hr output AM5101 - 1gm/hr output with countdown timer AM5200 - 2gm/hr output AM5201 - 2gm/hr output with countdown timer For settings see appendix A...
  • Page 2: Health And Safety

    Ozone is only dangerous if used irresponsibly, therefore it is important to follow the guidelines detailed in this manual. Due to the high levels of Ozone produced by the unit it is strongly recommended that no person or animal be in the room when the unit is running.
  • Page 3: Unit Description

    3.0 UNIT DESCRIPTION The AM5000 series of generator is designed to convert Oxygen found in the normal air into Ozone. It does this using the Corona Discharge (CD) principle, where air is blown over a ceramic plate with a stainless steel electrode, known as an open cell.
  • Page 4: Operation

    The output setting of the unit will depend upon the model of generator used, the volume of the room to be treated and the level of Ozone required. The Ozone level achieved in a room will depend on the room size, temperature, humidity, the number of air changes, the length of time the Ozone generator is run and the output setting.
  • Page 5 “CAUTION THIS ROOM IS BEING OZONISED DO NOT ENTER BETWEEN XX O’CLOCK AND XX O’CLOCK” at the entrances.  If you need to enter an Ozonised room with a high Ozone concentration, use a mask. A suitable Ozone mask is 3M Respirator type 9925.
  • Page 6 5.2.2 ON/OFF Control Panel.  Connect the unit to the electrical supply and start treatment. The red mains switch on the control panel will illuminate to indicate that the unit is running.  It is recommended that this panel is used in conjunction with an external power switch or plug in timer to turn the unit off remotely.
  • Page 7: Maintenance And Servicing

    d) Connecting the generator: Plug the generator into the socket of the timer and insert the timer into a socket outlet. Ensure the outlet socket is switched on. e) Timed switching: Ensure the red slide switch on the side of the timer is set to the centre (AUTO) position, with the clock face symbol.
  • Page 8 NOTE: the lid has an earth lead attaching it to the base, take care when removing the lid not to stress the lead.  Check the overall condition inside the unit and remove any debris.  Check that all the electrical connections are in good condition. ...
  • Page 9 GENERATOR FAN PLATE ASSEMBLY PLATE SUPPORT BRACKET CLEAN THIS SURFACE ENSURING ALL DEPOSITS ARE REMOVED. AM5000 Doc. No. 290-062-00 rev. A June 2005...
  • Page 10: Troubleshooting

    Possible Cause Suggested Action No power to unit Power not switched on Switch on power Fuse in plug blown Replace fuse (3A) No Ozone smell Generator cell(s) not Check and correct connected. Generator cells damaged Replace damaged cell(s) Generator cell(s) dirty...
  • Page 11 (b) leave the next two segments "up"; c) push down the next two segments. 4) Do not enter the treated room until at least two hours after the ozone generator has stopped. Example A room measures 20m x 5m x 3m.

This manual is also suitable for:

Am5100Am5101Am5200Am5201

Table of Contents