TABLE OF CONTENTS PRODUCT INFORMATION Important Safeguards..........4 Cautions Before Installation.........6 Safety Information............9 Main Unit & Parts............12 PRODUCT INSTALLATION Installation..............14 Operation..............20 PRODUCT SETTINGS Cleaning...............27 Maintenance...............29 Before Calling For Service........31 Specifications............32 WARRANTY Warranty..............33...
IMPORTANT SAFEGUARDS READ ALL OPERATING INSTRUCTIONS BEFORE INSTALLATION WARNING - To reduce the risk of burns, electric shock, fire, or injury. NOTES 1. Close supervision is necessary when this appliance is used by or is near infants, elders, or with disability persons. Children should not be 1.
CAUTIONS BEFORE INSTALLATION NOTE THE FOLLOWING IMPORTANT POINTS WIRING REQUIREMENTS 1. Do not install in a location where water might be splashed on this 1. After installation, all other servicing should be performed appliance or in a location exposed to excessive moisture where by authorized service representatives.
CAUTIONS BEFORE INSTALLATION (CONT.) SAFETY INFORMATION (DANGER) DANGER - FAILURE TO FOLLOW MAY CAUSE SEVERE INJURY 3. This product is for use on a nominal 120V circuit. It has a grounding plug that is similar to the plug illustrated in sketch A. A temporary OR DEATH.
Page 6
SAFETY INFORMATION (WARNING) WARNING - MIGHT CAUSE SLIGHT INJURY OR DAMAGE. BE AWARE. • Be aware of low-grade burn. It may result in a low-grade burn if sitting on the heated seat for a long time. Be aware of being used for the following: children, senior citizens, patients, people who cannot control the temperature, people who are not sober, or tired people.
MAIN UNIT & PARTS Washer (2pcs) Mounting bolt (2pcs) (seat cover) Nut (2pcs) Caution labe l Cone packing (2pcs) Remote control Remote control Bracket Screw (2pcs) Plastic anchor (2pcs) Hose clip (5pcs) AAA Battery (3ea) Power plug Nozzle Side control but t ons Heated sea t Occupi e d sen sor 15mm8...
INSTALLATION If electric work is needed, please contact a qualified Mounting the Plate electrician or serviceman only. Place the mounting plate over Remove the Existing Toilet Lid and Seat each mounting hole. Insert the mounting bolts through the plate 1. Remove the nuts, washers, and cone packings from the and mounting holes.
Page 9
INSTALLATION (CONT.) Connecting the Water Hose How To Attach the Unit Using Inline Carbon Filter - The use of an external inline carbon water filter 1. Use the tab on the mounting plate and is not required unless the unit is used in an area with extreme hard water. If a align it with the track on the seat, for a carbon filter is used, the filter must be replaced every 6 months.
Page 10
INSTALLATION (CONT.) Trial Operation 1. Preparation Plug the power cord into the outlet, and then the water tank will be filled in 2 minutes. 2. Checking All Functions Cover the toilet bowl using the sheet of plastic wrap on the unit to prevent the washing water from being sprayed out of the toilet.
OPERATION • Press “Dry” Warm air will come out for 3 minutes. • To alter the strength of drying, press the button again. • Dry temperature can be adjusted by pressing LOW or HIGH button to 5 levels. Cleansing • Press “Cleansing” to clean your posterior. The function will stop in 2 minutes automatically.
Page 12
OPERATION (CONT.) Temperature Adjustment (Water/Seat) Water Pressure (Cleansing/Bidet) • The temperature of seat and water can be adjusted by • Water spray pressure can be adjusted by pressing pressing button. LOW or HIGH button to 5 levels. • There are 4 levels (Room temp-Low-Medium-High) •...
Page 13
OPERATION (CONT.) User Setting Identification • Each button can save 2 settings. (Cleansing, Bidet) • This function is useful for public toilets when more than one unit of this product is installed. • Press the User 1 button and Cleansing or Bidet consecutively. Then choose nozzle position by pressing the FRONT/REAR button and water pressure •...
OPERATION (CONT.) CLEANING Set the Unit CAUTION: Do not forcefully push, pull, or bend the nozzles. It may result in failure. Make sure to use the “Stop” button • Unplug the unit and then plug it back in. on the remote control. •...
CLEANING (CONT.) MAINTENANCE Strainer Maintenance Draining Water - while not using over extended period of time. • This appliance will not operate properly if the strainer is clogged. Unplug the Power Supply Cord. Be sure to clean the strainer regularly. •...
MAINTENANCE (CONT.) BEFORE CALLING FOR SERVICE Screw the Drain Bolt and Install the Appliance PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION • Refer to the trial operation method to • Check for the power cord Completely Is there a power outage? use this appliance again. fails to work Is the power cord unplugged? failure or a tripped breaker.
SPECIFICATIONS WARRANTY USPA Personal Hygiene Appliance Limited Warranty ITEM Standard power supply AC 120V 60Hz 1248W We warrant our products to be free from manufacturing defects under normal use and service for a period of one (1) year from the date of your purchase. Water Way of connection Direct connection to tap water...
Page 18
WARRANTY (CONT.) of merchantability or fitness for use, are expressly limited to the duration of this warranty. Warning! We are not responsible or liable for any failure of, or damage to, this plumbing product component caused by in-tank bowl cleaners containing chlorine (calcium hypocrite).
Page 19
Thank You Technical Support/Customer Service 7900 S Route 31 Crystal Lake, IL 60014 T: 847.458.2334 U.S. TOLL FREE: 877.339.5214 support@biobidet.com www.biobidet.com...