T-Rail 105 Note: ER-PB-CP/D/A and ER-S-STIIA/D only used on STII double support mounting systems. Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 4 of 18...
Page 5
STII-A, Post brace for C-Post/Post brace for C-Post On double support STII-A, Post head for C-Post T-Rail 110 Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 5 of 18...
Page 6
Step 5: PV modules installation Note: See steps below before beginning double support installation. It is similar to the single support systems. Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 6 of 18...
Page 7
Installation Spacing Max Frame Spacing and Footing Options of Panel Dimensions 1.7m x 1m Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 7 of 18...
Page 8
*For SolarTerrace II-A driven post installation, maximum post height above ground is 1.3m. *For SolarTerrace II-A concrete pier installation, maximum post height above ground 1.5m. Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 8 of 18...
Page 11
M12 bolt and nut supplied. Recommended torque: 55 Nm Tube of the pre- assembled Post support Brace Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 11 of 18...
Page 12
④. Rotation the orientation of T head to in order to prevent the Tube Support can’t fit the post brace quite well. Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 12 of 18...
Page 13
Tube Support T head Bolt 3 Bolt4 Bolt 3 Bolt 2 Bolt 3 Bolt 2 Bolt 2 Bolt 2 Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 13 of 18...
Page 14
6a. Note: Connecting Rails Structure system are not recommended. 6c. Now the Racking System is completed. Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 14 of 18...
Page 15
Tip: Use Inter Clamp U18 as the gap location. Recommended Torque: M8:20Nm 7b.The installation is complete. Clenergy Australia | 1/10 Duerdin St, Clayton VIC 3168 | T: +61 3 9239 8088 | sales@clenergy.com.au Page 15 of 18...