  • Page 1 FlexDSL GigaFlex DIN-RAIL UNITS TECHNICAL DESCRIPTION AND INSTALLATION MANUAL Version Document name UM_Flexdsl-Gigaflex_Installation_V1-1.Docx Revision 11 October 2019...
  • Page 2 Technical Description and Installation Manual GigaFlex © Copyright 2019 by FlexDSL Telecommunications AG. The content of this publication may not be reproduced in any part or, as a whole, transcribed, stored in a retrieval system, translated into any language, or transmitted in any form or by any means, electronic, mechanical, magnetic, optical, chemical, photocopying, manual, or otherwise, without the prior written permission of FlexDSL Telecommunications AG.
  • Page 3: Table Of Contents

    Technical Description and Installation Manual GigaFlex VERSION CONTROL......................... 4 SAFETY REGULATIONS ......................4 EU DIRECTIVE 2002/96/EC AND EN50419 ................4 SELECTION GUIDE ......................5 PRECAUTION ........................6 TECHNICAL DESCRIPTION ....................7 General Information ...................... 7 LED Indicator and Connector Pin Assignment on Front Panel ........8 GigaFlex Interface Description ...................
  • Page 4: Version Control

    ACCESSIBLE AND THE MAINS PLUG HAS TO BE NEXT TO THE RACK IF THE MAINS PLUG SERVES AS THE DISCONNECTING DEVICE. IT’S ONLY ALLOWED TO USE THE UNITS WITH HOUSINGS SUPPLYED FROM FLEXDSL TELECOMMUNICATIONS AG (SUBRACKS, MINIRACK, UTTX). THE RACK HAS TO BE CONNECTED PERMANENTLY TO A RELIABLE PROTECTIVE EARTH CONDUCTOR.
  • Page 5: Selection Guide

    Technical Description and Installation Manual GigaFlex 1 SELECTION GUIDE Functionality FlexDSL GigaFlex Models      GF-RAIL2N-6Eth-2I2O/2SER-24V,V21       GF-RAIL2N-6Eth-2I2O/2SER-PoE-24V,V25    GF-RAIL2N-6Eth-24V,V26      GF-RAIL4N-6Eth-2I2O/2SER-24V,V31    ...
  • Page 6: Precaution

    GigaFlex 2 PRECAUTION The present document describes the FlexDSL GigaFlex product family. The document contains the technical description and the installation instruction of all devices. Appendices containing additional information about the system are also an integral part of the present document.
  • Page 7: Technical Description

    3 TECHNICAL DESCRIPTION General Information The FlexDSL GigaFlex product family is designed to support high speed data transmission over copper and fiber cables with a complete Layer 2/3 Ethernet switching functionality. It fully complies with the field-proven ITU-T G.991.2 SHDSL technology and IEEE 802.3ah Ethernet in the First Mile (EFM) encapsulation.
  • Page 8: Led Indicator And Connector Pin Assignment On Front Panel

    Technical Description and Installation Manual GigaFlex The following protocols are supported to grant an easy and secure access by a network administrator: • Local Command Line Interface (CLI) access over the Local Craft Terminal (LCT) with USB or RS232. • Remote Command Line Interface (CLI) access over Telnet or SSH.
  • Page 9 Technical Description and Installation Manual GigaFlex Element Description Power LEDs Two bicolor LEDs red/green representing -V1 and -V2 input voltages status Device Status Status No input voltage detected LED1 LED2 Green Input voltage detected, No Alarm Amber Input voltage detected, Minor Alarm Input voltage detected, Major Alarm / Device Boot 4-pin Phoenix Mini Combicon MC 1,5/4-GF-3,81 (female) Pin No.
  • Page 10 Technical Description and Installation Manual GigaFlex Element Description Slot for MicroSD card with Tray USB Type Mini-B female connector for Console access HOST USB Type A female connector for Flash Stick Factory Default button Two SFP cages for mini GBIC 1000Base-X modules RJ45 Four 10/100/1000Base-TX Ethernet connectors with MDI/MDIX support Four bicolor red/green LEDs representing DSL status...
  • Page 11: Gigaflex Interface Description

    Technical Description and Installation Manual GigaFlex Element Description Four RJ45 Female connectors with integrated LEDs and two SFP cages Description Connector overview Ethernet Act blinking: 340ms: 10H/10F Gigabit Ethernet Green 170ms: 100H/100F LEDs 84ms: 1000H/1000F Yellow 100/1000Base-TX mode Ethernet Act blinking for Port 1: 84ms: 1000H/1000F SFP LEDs Ethernet Act blinking for Port 2:...
  • Page 12: Shdsl Annex A/B

    Technical Description and Installation Manual GigaFlex • Normal Mode: only TC-PAM16 and TC-PAM32 modulations are supported. • Extended Mode: offers all modulations from TC-PAM4 to TC-PAM128; extends maximum possible data rates for TC-PAM16 and TC-PAM32 modulations. 3.3.1.2 SHDSL Annex A/B The GigaFlex models support two PSD (Power Spectral Density) operation modes: Annex A and Annex B.
  • Page 13: Point-To-Multipoint (Star Structure)

    Technical Description and Installation Manual GigaFlex 3.3.1.5.2 Point-to-Multipoint (Star Structure) A point-to-multipoint connection is a connection of different places with a central point. This can be realized with just one or multiple copper pairs. Figure 3-5. Point-to-multipoint connection 3.3.1.5.3 Daisy Chain (Line Structure) In a daisy chain you connect the devices in series and in each device, you can add/drop Ethernet data.
  • Page 14: Interface Conversion And Redundancy

    Technical Description and Installation Manual GigaFlex Figure 3-7. Ring structure connection 3.3.1.5.5 Interface Conversion and Redundancy The GigaFlex models support redundant data connections. Redundancy can be achieved by following ways: • Data connection by multiple copper pairs • Data connection by multiple fiber cables •...
  • Page 15: Power Over Ethernet (Poe)

    Technical Description and Installation Manual GigaFlex • RFC 2453 RIPv2 • RFC 5798 VRRPv3 • RFC 3228 OSPF v 2 • RFC 5340 OSPF v 3 • RFC 3164 Syslog • RFC 2819 RMON1 • RFC 4502 RMON2 • IGMP Detailed configuration examples of selected protocols can be found in the GigaFlex Configuration Manual.
  • Page 16: Lct Usb Connector

    Technical Description and Installation Manual GigaFlex circuit the Input switches its state to "closed". The Input changes its state into "open" if no current detected in the electric circuit. NO (normally open) NC (normally closed) Input a Input a Input b Input b Figure 3-10.
  • Page 17: Installation

    Technical Description and Installation Manual GigaFlex 4 INSTALLATION General Requirements Before installing the device, read carefully the present manual. Take care about all warnings inside this manual. Please note that the warrantee and free-of-charge repair will not be granted if the device failed due to one of the following conditions: a) Misuse and improper installation, including but not limited to: installation and use of the product in a conflicting way with the actual technical or safety...
  • Page 18: Connecting Power Input And Protective Ground

    Technical Description and Installation Manual GigaFlex Although the unit can be located either vertically or horizontally, the vertical position is preferred because this enables a better airflow. A comfort clip FG-RAIL-ComfortClip-Orion2/3 can be purchased separately. It simplifies the device installation on a DIN-rail. Connecting Power Input and Protective Ground Connect the power, for example -24VDC, to the power input terminal as it is shown on Figure 4-2.
  • Page 19: Maintenance

    Technical Description and Installation Manual GigaFlex 5 MAINTENANCE The GigaFlex models do not contain parts that require constant service or tuning during daily operation. You should keep the enclosure clean and periodically check the quality of contacts in jacks and in junctions. We recommend that you perform the following measurements and keep the following records: •...
  • Page 20: Technical Specification

    Technical Description and Installation Manual GigaFlex 6 TECHNICAL SPECIFICATION Interfaces 6.1.1 SHDSL Interface Specification: ITU-T G.991.2-G.SHDSL, ITU-T G.991.2-G.shdsl.bis IEEE 802.3ah (Ethernet in the First Mile) Line Code: TC-PAM16/32, Extended: TC-PAM4/8/64/128 Impedance: 135 Transmit Power: 13.5 (Annex A) or 14.5 (Annex B) dBm @ 135 Number of Pairs: 2 or 4 Bit Rate:...
  • Page 21: Usb Host

    Technical Description and Installation Manual GigaFlex ≤ 0W Power: Isolation (between contacts & coil): ≥ 00Vdc ( 0us Telcordia) +3.3Vdc Power Output: max 100mA Connector Type: 12 pin Phoenix Mini Combicon MCD 1,5/ 6-G1F-3,81 (female) 6.1.6 USB Host Specification: USB V2.0 full and low speed Data Rate: 12Mbit/s Protocol:...
  • Page 22: Environment

    Technical Description and Installation Manual GigaFlex Environment 6.4.1 Climatic Conditions °C … 0°C) Storage: ETS 300 019-1-1 Class 1.2 ext. (- ETS 300 019-1-2 Class 2.3 (- 0°C … 0°C) Transportation: °C … 0°C) Operation: ETS 300 019-1-3 Class 3.2 ext. (- 6.4.2 Safety / EMC Safety: IEC 60950-1:2005+A1:2009+A2:2013...

Table of Contents