Jolywood JW-HD120N Accessory Installation Manual

N-type mono-crystalline double glass module
Hide thumbs Also See for JW-HD120N:

Advertisement

INSTALLATION
MANUAL
Jolywood N-type Mono-crystalline Double Glass Module
All rights reserved © Jolywood (Taizhou) Solar Technology Co., Ltd

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JW-HD120N and is the answer not in the manual?

Questions and answers

Summary of Contents for Jolywood JW-HD120N

  • Page 1 INSTALLATION MANUAL Jolywood N-type Mono-crystalline Double Glass Module All rights reserved © Jolywood (Taizhou) Solar Technology Co., Ltd...
  • Page 2: Table Of Contents

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Revision Date 2020/3/16 Version: JW-Install-D-2020-V1 Contents Introduction ………………………………………………………………… Disclaimer …………………………………………………………………… Limitation of Liability ………………………………………………………… Safety Precautions …………………………………………………………… Warning ……………………………………………………………………… General Safety ……………………………………………………………… Operation instruction ………………………………………………………… Unload Transportation and Storage ………………………………………… Marks on Outer Packaging ……………………………………………………...
  • Page 3: Introduction

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Introduction Declaration This manual contains relevant information Jolywood reserves the right to change this ab o ut t he inst a ll a t io n me t h o ds a n d sa fe installation manual without prior notice.
  • Page 4: Operation Instruction

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Do not artificially gather sunlight on these solar scratching, cutting the cables and connectors or modules. exposed under the sun for a long time. Do not drop module or drop other things onto the module 2.2.2...
  • Page 5: Marks On Outer Packaging

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Always work under a dry environment, ensure that all modules and electrical contacts are clean and dry before installation. If it is necessary to store the modules outdoors for a certain period of time, always cover module...
  • Page 6: Unloading Warning

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Unloading Instructions packaging when the project checked at the site. 3.2.1 One layer stacking for transport only allowed at project site. During transport, secure the box When unloading the modules from the...
  • Page 7: Unpacking Steps

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 4.1.2 pa pe r o f t h e o u te r bo x , a n d p ro h i b i t t he custom unpacking method.
  • Page 8: Installation Safety

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module completely during installation. Do not open the the p rod uc t ha s b e e n te s t e d t o v e ri f y i ts...
  • Page 9: Installation Method

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Installation method Fixture installation meth: 5.2.1 JW-HD120N/P Mechanical installation and precautions Modules could be mounted with clamps or bezels. Modules Installation must be ca rri ed ou t a c c o rdi n g t o th e f o l lo w ing ex amp le s a nd re c o mme n d a t io n s .
  • Page 10: Framed Bifacial Double-Glass Modules(Installation With Bolt

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module JW-HD144N/P Note: The above standard installation is used in the jolywood standard Clamp. For details, please refer to the jolywood standard clamp drawing. 5.2.3 Framed Bifacial Double-Glass modules ((installation with bolt)...
  • Page 11 Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 5.2.3.3 JW-HD120N/P The tensile strength of M8*16 stainless steel outer hexagonal bolts, nuts, bolts and nuts should not be less than 700MPa, and the recommended torque is 16 Newton・ m. 5.2.3.4...
  • Page 12: Grounding

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module JW-HD144N/P The equipment must be installed in accordance with the instructions given by the grounded equipment manufacturer. 5.2.4.3 Please visit http://www.jolywood.cn/ to view the “Product Catalog” link for detailed grounding holes locations and dimensions.
  • Page 13: Electrical Installation

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 5.2.5 r e q u i r e d t h a t a l l w i r i n g a n d e l e c t r i c a l...
  • Page 14: Maintenance For Pv Modules

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module Maintenance for PV Modules Module Visual Inspection and Replacement Modules in array should be regularly inspected to check damage modules. If damage module is founded, it must be replaced with same type one. Such as broken glass, broken cables, damaged junction box, etc., which would lead to functional and safety...
  • Page 15: Connector And Cable Inspection

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module to be replaced. Module must be replaced o f l i gh t th a t f a l ls o n i t. A b a tt e ry-b l ocke d with same type one.
  • Page 16: Water Quality Requirements

    Installation Manual - Jolywood N-type Mono-crystalline Double Glass Module 6.3.3 verification should be carried out only under Troubleshooting a stable sunshine rate (sunny, strong sunshine, no cloud) I f i t do e s n o t w o rk a ft e r i n st a l l at i on, please notify the installer immediately.