Cinterion ® DGL61-W Hardware Interface Description Page 3 of 42 Contents Contents Document History ...................... 7 Introduction ......................... 9 Related Documents ................... 9 Terms and Abbreviations ................. 10 Regulatory and Type Approval Information ............. 12 1.3.1 Directives and Standards..............12 1.3.2 Safety Precautions................
Page 4
Mechanics, Mounting and Packaging ..............34 Mechanical Dimensions ................... 34 Mounting Clip (optional) ................... 35 Packaging ......................36 Full Type Approval....................37 Thales Reference Setup .................. 37 Restrictions ...................... 38 CE Conformity....................38 EMC ......................... 38 RF Exposure Information ................. 38 Compliance with FCC and ISED Rules and Regulations.........
Page 5
Cinterion ® DGL61-W Hardware Interface Description Page 5 of 42 Tables Tables Table 1: Terms and abbreviations................. 10 Table 2: Directives ......................12 Table 3: Standards of North American type approval ........... 12 Table 4: Standards of European type approval............. 13 Table 5: Requirements of quality ..................
Page 6
Cinterion ® DGL61-W Hardware Interface Description Page 6 of 42 Figures Figures Figure 1: Sample Device Gateway LTE label DGL61-W..........17 Figure 2: Installed USB devices ..................22 Figure 3: Connection via USB interface (USB modem) ..........22 Figure 4: Device Gateway LTE 3D view.................
Cinterion ® DGL61-W Hardware Interface Description Page 7 of 42 0 Document History Document History ® Preceding Document: Cinterion Device Gateway LTE Hardware Interface Description" Version 06 ® New document: "Cinterion Device Gateway LTE Hardware Interface Description" Version 07 Chapter What is new 1.3.1 Added standards/regulations regarding RF exposure to...
Page 8
Cinterion ® DGL61-W Hardware Interface Description Page 8 of 42 0 Document History 4.6.1 Revised chapter to behavior of DGL61-W 4.10 Revised chapter regarding color of the LEDs 5.1, Revised in power supply voltage Table 11 Table 12 New Chapter regarding RF output power Revised values in Table 15 New Chapter for Mounting Clip...
PLS62-W AT Command Set Getting Started with DGL61-W Java User‘s Guide 1. The document is effective only if listed in the appropriate Release Notes as part of the technical docu- mentation delivered with your Thales product. DGL61-W_HID_v07 2021-02-17 Public / Preliminary...
Cinterion ® DGL61-W Hardware Interface Description Page 10 of 42 1.2 Terms and Abbreviations Terms and Abbreviations Table 1: Terms and abbreviations Abbreviation Description Antenna Reference Point AT Command Base Transceiver Station Cell Broadcast CODEC Coder-Decoder Digital Audio Interface Data Circuit terminating Equipment Data Set Ready Data Terminal Ready Enhanced Full Rate...
Page 11
Cinterion ® DGL61-W Hardware Interface Description Page 11 of 42 1.2 Terms and Abbreviations Table 1: Terms and abbreviations Abbreviation Description Not Connected Negative Temperature Coefficient Power Amplifier Printed Circuit Board Pulse Code Modulation Personal Communication System Power Down Protocol Data Unit Power over Ethernet Radio Equipment Directive Radio frequency...
Cinterion ® DGL61-W Hardware Interface Description Page 12 of 42 1.3 Regulatory and Type Approval Information Regulatory and Type Approval Information 1.3.1 Directives and Standards Device Gateway LTE have been designed to comply with the directives and standards listed below. Table 2: Directives 2014/53/EU Directive of the European Parliament and of the council of 16 April 2014...
Cinterion ® DGL61-W Hardware Interface Description Page 13 of 42 1.3 Regulatory and Type Approval Information Table 4: Standards of European type approval 3GPP TS 51.010-1 “Digital cellular telecommunications system (Phase 2); Mobile Station (MS) conformance specification” ETSI EN 301 511 V12.5.1 Global System for Mobile communications (GSM); Mobile Stations (MS) equipment;...
Cinterion ® DGL61-W Hardware Interface Description Page 14 of 42 1.3 Regulatory and Type Approval Information Table 6: Standards of the Ministry of Information Industry of the People’s Republic of China SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Sub- stances in Electronic Information Products”...
Failure to comply with these precautions violates safety standards of design, manu- facture and intended use of the product. THALES DIS AIS Deutschland GmbH assumes no li- ability for customer’s failure to comply with these precautions.
Cinterion ® DGL61-W Hardware Interface Description Page 16 of 42 1.3 Regulatory and Type Approval Information IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks. In that case connections cannot be guaranteed at all times under all conditions. There- fore, you should never rely solely upon any wireless device for essential communi- cations, for example emergency calls.
Cinterion ® DGL61-W Hardware Interface Description Page 17 of 42 1.4 Product Label Product Label The label fixed to the bottom of a comprises the following information. Device Gateway LTE Figure 1: Sample Device Gateway LTE label DGL61-W Table 8: Device Gateway LTE label information Information Company name of the manufacturer (address see back page of this document) Cinterion Logo (trademark)
Cinterion ® DGL61-W Hardware Interface Description Page 18 of 42 2 Product Concept Product Concept Key Features at a Glance Feature Implementation General ® Incorporates Cinterion The Java module handles all signal and data processing within the Device Java module Gateway LTE.
Page 19
RoHS, WEEE All hardware components are fully compliant with the EU RoHS and WEEE Directives Software AT commands Hayes 3GPP TS 27.007, TS 27.005, Thales Java™ Open Platform Java™ Open Platform with • Java™ profile IMP-NG & CLDC 1.1 HI •...
Page 20
Cinterion ® DGL61-W Hardware Interface Description Page 20 of 42 2.1 Key Features at a Glance Feature Implementation TCP/IP stack Protocols: TCP server/client, UDP, DNS, Ping, HTTP, FTP, SMTP Access by AT commands Firmware update Upgradeable via USB interface Antenna two internal antennas for maximum RF performance Interfaces USB interface...
Windows, e.g. Windows Hyperterminal. Start Up the DGL61-W Note: If the USB interface is to be employed, the USB drivers provided by Thales need to be available. Copy the supplied driver files to a folder on the Windows computer. Be sure to use the latest USB driver software supplied by Thales.
® Cinterion DGL61-W Hardware Interface Description Page 22 of 42 3.2 Start Up the DGL61-W Figure 2: Installed USB devices • To connect to the DGL61-W via USB interface, check the properties of the enumerated USB devices for the configured COM ports, for example the "Cinterion PLSx USB Modem", call a terminal program on the PC and connect to the configured COM port.
Cinterion ® DGL61-W Hardware Interface Description Page 23 of 42 4 Interface Description Interface Description Overview Device Gateway LTE provide the following interfaces for power supply/ data transfer and micro SIM card: Table 9: Device Gateway LTE‘ interfaces Description USB 2.0 cable with USB-A connector 4 Status LEDs micro SIM card reader Figure 4: Device Gateway LTE 3D view...
Cinterion ® DGL61-W Hardware Interface Description Page 25 of 42 4.3 Operating Modes Operating Modes The table below briefly summarizes the various operating modes referred to in the following chapters. Table 10: Overview of operating modes Normal operation GSM IDLE Software is active.
Cinterion ® DGL61-W Hardware Interface Description Page 26 of 42 4.5 Power Supply Power Supply The DGL61-W power supply via USB has to be a single voltage source of 5V DC. When power fails for >1ms, DGL61-W safely power down and restarts when power is back and valid.
Cinterion ® DGL61-W Hardware Interface Description Page 27 of 42 4.7 Automatic thermal shutdown 4.6.4 Disconnecting power supply The DGL61-W can be disconnected at any time because the DGL61-W is protected against sudden power loss (USB disconnection). Automatic thermal shutdown An on-board NTC measures the temperature of the built-in Java module.
Cinterion ® DGL61-W Hardware Interface Description Page 28 of 42 4.9 SIM Interface SIM Interface The SIM interface is intended for 1.8V and 3V micro SIM cards in accordance with GSM 11.12 Phase 2. The card holder is a five wire interface according to GSM 11.11. A sixth pin has been added to detect whether or not a SIM card is inserted.
Cinterion ® DGL61-W Hardware Interface Description Page 29 of 42 4.10 Status LEDs 4.10 Status LEDs Device Gateway LTE has four LEDs indicating its operating states: • A green LED indicates whether the Device Gateway LTE is powered or not •...
Cinterion ® DGL61-W Hardware Interface Description Page 30 of 42 5 Electrical and Environmental Characteristics Electrical and Environmental Characteristics Absolute Maximum Ratings Table 11: Absolute maximum ratings Parameter Port / Description Min. Max. Unit Supply voltage USB interface All electrical characteristics according to USB Implementers' Forum, USB 2.0 Specification.
Cinterion ® DGL61-W Hardware Interface Description Page 31 of 42 5.4 USB Interface Table 14: RF Output Power Technology RF Output Power UMTS Output power Class 3 (+24dBm +1/-3dB) for UMTS 800, WCDMA FDD BdXIX (according to Release 8) Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV Class 3 (+24dBm +1/-3dB) for UMTS 900, WCDMA FDD BdVIII Class 3 (+23.8dBm +0.1/-2.8dB) for UMTS AWS, WCDMA FDD BdIV Class 3 (+24dBm +1/-3dB) for UMTS 1800, WCDMA FDD BdIX...
Cinterion ® DGL61-W Hardware Interface Description Page 32 of 42 5.5 Operating Temperatures Operating Temperatures Table 15: Temperature characteristics Parameter Typical Unit Normal (unlimited) Operation +50°C °C Extended Operation to +70 °C Automatic thermal restart <-40 >+90 °C 1. Maximum time to transmit to keep DGL61-W below the automatic thermal restart limit. 50s Maximum transmit to idle ratio to keep DGL61-Wbelow the automatic thermal restart limit: 1:3 Both condition, max time and ratio, mustn't be violated to keep DGL61-W in a safe operation condi- tion without thermal restart, e.g.
Cinterion ® DGL61-W Hardware Interface Description Page 34 of 42 6 Mechanics, Mounting and Packaging Mechanics, Mounting and Packaging Mechanical Dimensions Figure 8 shows a 3D view of the Device Gateway and provides an overview of the mechanical dimensions of the device. For further details see Figure 9 Section 6.3.
Cinterion ® DGL61-W Hardware Interface Description Page 35 of 42 6.2 Mounting Clip (optional) 19.5 mm 73.5 mm Figure 9: Device Gateway LTE mechanical dimensions Mounting Clip (optional) For mounting the DGL61-W there is a mounting clip available (see Figure 10).
Cinterion ® DGL61-W Hardware Interface Description Page 36 of 42 6.3 Packaging Packaging Device Gateway LTE come in boxes: • Box size: 183 mm x 141 mm x 32mm DGL61-W_HID_v07 2021-02-17 Public / Preliminary...
Page 37 of 42 7 Full Type Approval Full Type Approval Thales Reference Setup The Thales reference setup submitted to type approve Device Gateway LTE consists of the fol- lowing components: • Device Gateway LTE with approved Java module •...
Cinterion ® DGL61-W Hardware Interface Description Page 38 of 42 7.2 Restrictions Restrictions Later enhancements and modifications beyond the certified configuration require extra approv- als. Each supplementary approval process includes submittal of the technical documentation as well as testing of the changes made. •...
• Consult the dealer or an experienced radio/TV technician for help. Changes or modifications made to this equipment not expressly approved by Thales may void the FCC authorization to operate this equipment. This device contains UMTS, GSM and GPRS class functions in the 900 and 1800 MHz bands that are not operational in U.S.
Page 40
DGL61-W Hardware Interface Description Page 40 of 42 7.6 Compliance with FCC and ISED Rules and Regulations Please contact us for more information on the FCC Compliance details mentioned above: Thales Edgar Canizales Arboretum Plaza II 9442 Capital of Texas Highway, Suite 400...
DGL61-W Hardware Interface Description Page 41 of 42 8 Ordering Information Ordering Information Table 18: Ordering Information Description Supplier Ordering information DGL61-W Thales L30960-N6800-A100 USB Cable length: 200mm Other USB Cable length (0.5m, 1m) on request DGL61-W Mounting Clip Thales t.b.d. DGL61-W_HID_v07...
Need help?
Do you have a question about the Cinterion DGL61-W and is the answer not in the manual?
Questions and answers