INSTRUCTION MANUAL
IM450-U v3.1
EMC-D3b
EMC-D3b-485
AVAILABLE MODELS
EMC-D3b: 3-phase energy counter with 7+1 digit display. 1 digital
input and two digital pulse output for kWhr and kVArhr.
EMC-D3b-485: 3-phase energy counter with 7+1 digit display, 1
digital input, two digital pulse output for kWhr and kVArhr, EIA-
RS485 serial communication port, Modbus RTU protocol.
Both are manufactured in DIN rail mounting case 6 modules 17.5
mm.
INTRODUCTION
The EMC-D3b models allows the local or remote counting of the
energy, with the help of a serial interface.
It is possible to set the instrument to count in 3 differents mode
(Normal / Total and partial / Timeband).
Also the instrument is equipped with a digital input which can cover differents function. See the
more information.
The auxiliary power supply is taken from same Voltage inputs (VL1 and VL2), used for measuring.
It's available as option the instrument for single phase networks.
OPTIONS and ACCESSORIES
options: - internal CT's ( not for direct line insertion) (order with -t suffix)
- current inputs for ... /1A current transformer (order with /1A suffix)
- current sensor for low current measures (Max 15 Amp) (specify when ordering)
- power supply and measuring voltages other than the standard (specify when ordering)
- power supply separated from measuring voltage (specify when ordering)
- single phase network ( power supply is taken from VL1 and neutral) (specify when ordering)
MEASURED PARAMETERS
Parameters showed in counter mode
three phase system active energy
three phase system reactive energy
three phase system apparent energy
Parameters showed in meter mode
phase voltages
phase to phase system voltages
phase currents
phase power factors
phase active powers
phase reactive powers
phase apparent powers
frequency
These parameters are available only on EMC-D3b-485 model and readable only by RS485 interface.
Peak, average and max demand value
maximum phase voltages
maximum phase currents
maximum three-phase powers
maximum average phase currents (maximum demand)
maximum average three-phase powers (maximum demand)
average phase currents
average three-phase powers
EMC-D3b
EMC-D3b-485
ENERGY MULTIFUNCTION COUNTER
[kWhr]
[kVArhr]
[kVAhr]
[V-kV]
[V-kV]
[A-kA]
[W-kW-MW]
[VAr-kVAr-MVAr]
[VA-kVA-MVA]
[Hz]
[V-kV]
[A-kA]
[W-VAr-VA (k-M)]
[A-kA]
[W-VAr-VA (k-M)]
[A-kA]
[W-VAr-VA (k-M)]
instructon manual
Unit of measure
unit of measurement
V
V
A
PF
W
VAr
VA
Hz
unit of measurement
V
A
W
I
L1 max (avg)
W
A
W
IM450-U v3.1
digital input
Identifying abbreviations
kWh
kVArh
kVAh
initial identification
V
V
L1-N
L2-N
L3-N
V
V
L1-L2
L2-L3
L3-L1
A
A
L1
L2
L3
PF
PF
L1
L2
L3
W
W
L1
L2
L3
VAr
VAr
L1
L2
L3
VA
VA
L1
L2
L3
L1
Initial identification
V
L1-N max
L2-N max
A
L1 max
L2 max
VAr
max
max
I
L2 max (avg)
VAr
max (avg)
max (avg)
A
L1 avg
L2 avg
VAr
avg
avg
section for
V
L3-N max
A
L3 max
VA
max
I
L3 max (avg)
VA
max (avg)
A
L3 avg
VA
avg
page 1
Need help?
Do you have a question about the EMC-D3b and is the answer not in the manual?
Questions and answers