Contrel EMC-D3b Instruction Manual

Energy multifunction counter

Advertisement

Quick Links

INSTRUCTION MANUAL
IM450-U v3.1
EMC-D3b
EMC-D3b-485
AVAILABLE MODELS
EMC-D3b: 3-phase energy counter with 7+1 digit display. 1 digital
input and two digital pulse output for kWhr and kVArhr.
EMC-D3b-485: 3-phase energy counter with 7+1 digit display, 1
digital input, two digital pulse output for kWhr and kVArhr, EIA-
RS485 serial communication port, Modbus RTU protocol.
Both are manufactured in DIN rail mounting case 6 modules 17.5
mm.
INTRODUCTION
The EMC-D3b models allows the local or remote counting of the
energy, with the help of a serial interface.
It is possible to set the instrument to count in 3 differents mode
(Normal / Total and partial / Timeband).
Also the instrument is equipped with a digital input which can cover differents function. See the
more information.
The auxiliary power supply is taken from same Voltage inputs (VL1 and VL2), used for measuring.
It's available as option the instrument for single phase networks.
OPTIONS and ACCESSORIES
options: - internal CT's ( not for direct line insertion) (order with -t suffix)
- current inputs for ... /1A current transformer (order with /1A suffix)
- current sensor for low current measures (Max 15 Amp) (specify when ordering)
- power supply and measuring voltages other than the standard (specify when ordering)
- power supply separated from measuring voltage (specify when ordering)
- single phase network ( power supply is taken from VL1 and neutral) (specify when ordering)
MEASURED PARAMETERS
Parameters showed in counter mode
three phase system active energy
three phase system reactive energy
three phase system apparent energy
Parameters showed in meter mode
phase voltages
phase to phase system voltages
phase currents
phase power factors
phase active powers
phase reactive powers
phase apparent powers
frequency
These parameters are available only on EMC-D3b-485 model and readable only by RS485 interface.
Peak, average and max demand value
maximum phase voltages
maximum phase currents
maximum three-phase powers
maximum average phase currents (maximum demand)
maximum average three-phase powers (maximum demand)
average phase currents
average three-phase powers
EMC-D3b
EMC-D3b-485
ENERGY MULTIFUNCTION COUNTER
[kWhr]
[kVArhr]
[kVAhr]
[V-kV]
[V-kV]
[A-kA]
[W-kW-MW]
[VAr-kVAr-MVAr]
[VA-kVA-MVA]
[Hz]
[V-kV]
[A-kA]
[W-VAr-VA (k-M)]
[A-kA]
[W-VAr-VA (k-M)]
[A-kA]
[W-VAr-VA (k-M)]
instructon manual
Unit of measure
unit of measurement
V
V
A
PF
W
VAr
VA
Hz
unit of measurement
V
A
 W
I
L1 max (avg)
 W
A
 W
IM450-U v3.1
digital input
Identifying abbreviations
kWh
kVArh
kVAh
initial identification
V
V
L1-N
L2-N
L3-N
V
V
L1-L2
L2-L3
L3-L1
A
A
L1
L2
L3
PF
PF
L1
L2
L3
W
W
L1
L2
L3
VAr
VAr
L1
L2
L3
VA
VA
L1
L2
L3
L1
Initial identification
V
L1-N max
L2-N max
A
L1 max
L2 max
 VAr
max
max
I
L2 max (avg)
 VAr
max (avg)
max (avg)
A
L1 avg
L2 avg
 VAr
avg
avg
section for
V
L3-N max
A
L3 max
 VA
max
I
L3 max (avg)
 VA
max (avg)
A
L3 avg
 VA
avg
page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the EMC-D3b and is the answer not in the manual?

Questions and answers

Summary of Contents for Contrel EMC-D3b

  • Page 1 [VAr-kVAr-MVAr] phase apparent powers [VA-kVA-MVA] frequency [Hz] These parameters are available only on EMC-D3b-485 model and readable only by RS485 interface. Peak, average and max demand value unit of measurement Initial identification maximum phase voltages [V-kV] L1-N max...
  • Page 2: Installation

    CONNECTION 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 kVArh energy 8888888 8 EMC-D3b input In k/5A 3x(50-500V) 50-60Hz energy multifuncti o n out put 2 digital pulses/kWh-kVArh 100÷0,1 counter...
  • Page 3 Timeband T1 is selected when no voltage is applied, T2 when the input is powered Each parameters (kWh, kVArh and kVAhr) have two counters T1 and T2, in which the energy is counted depending the status of digital input. EMC-D3b EMC-D3b-485 instructon manual IM450-U v3.1...
  • Page 4 INSERTION ON THREE PHASE LINE WITH 3 WIRES AND 2 CT (insertion AARON) *the voltage insertion with 2 VT is possible only for the version with internal CT LOAD BALANCED THREE PHASE LINE LOAD EMC-D3b EMC-D3b-485 instructon manual IM450-U v3.1 page 4...
  • Page 5 DIGITAL I/O DIGITAL OUTPUTS Max 150mA Max 230Vac/dc NOTE: output DO1 for ACTIVE ENERGY pulses output DO2 for REACTIVE ENERGY pulses DIGITAL INPUT From 80 to 250 Vac From 90 to 250 Vdc EMC-D3b EMC-D3b-485 instructon manual IM450-U v3.1 page 5...
  • Page 6 FRONT PANEL DESCRIPTION – KEYS kVArh energy EMC-D3b input In k/5A 3x(50-500V) 50-60Hz energy multifunction output 2 digital pulses/kWh-kVArh 100÷0,1 counter 1 optional serial port EIA485 DESCRIPTION: : Push-button key for selecting the energy visualisation / for decreasing values when setting at SETUP.
  • Page 7 00.1 kW-kVAr / pulse 0.01 kW-kVAr / pulse 100 mS Set the duration pulse 200 mS 300 mS 400 mS 500 mS (only for EMC-D3b-485) Increase Set address of network from 001 to 247 Decrease Set baud rate 19200 baud 19.2...
  • Page 8 This setting allows to definite the wiring type connection. It’s possible to chose 3 wires or 4 wires. With the 4 wires connection the neutral parameter are displayed and enabled to use for the digital and analog outputs settings. EMC-D3b EMC-D3b-485 instructon manual IM450-U v3.1...
  • Page 9 Programming of the address for the communication network (ID) (only for EMC-D3b-485) After the confirm with the C key of the previous value, the message ID will appear on display; to set the value that will identify the instrument when it will be connected in a EIA485 communication network, proceed with the modality, already described.
  • Page 10 Visualisation apparent energy T1time band SWITCHED OFF SWITCHED OFF SWITCHED OFF BLINKING Energy counting on T2 time band Visualisation apparent energy T2time band SWITCHED OFF SWITCHED OFF SWITCHED OFF BLINKING Energy counting on T2 time band EMC-D3b EMC-D3b-485 instructon manual IM450-U v3.1 page 10...
  • Page 11 NOTE regarding to the measures. In some applications, in which the CT's secondary is connected to other instruments, different of the EMC-D3b counters, there might be some measuring problems, depending on the typology of the current inputs. Optionally, there are alternatives adapted to solve these possible problems.
  • Page 12 - From 80 Vac to 250 Vac, 50/60Hz - From 90 Vdc to 300Vcc, polarised. Serial output Only for EMC-D3b-485: one RS485 port, 2400 to 19200 baud's, MODBUS-RTU protocol GENERAL Display, operation keys 1 display with red LED's of 7,5 mm, made by 8 digits of 7 segments...

This manual is also suitable for:

Emc-d3b-485